Belden 1079A 16 Paare 20 + 1/C 22 AWG SPOS PLTC-ER Schwarz PVC Mantel specifications
AttributeValue
Pairs16
Pair Conductor Size20 AWG
Pair Stranding7x28
Pair Conductor MaterialBC - Bare Copper
Comm Wire(s)1
Comm Wire size22 AWG
Comm Wire stranding7x30
Comm Wire materialBC - Bare Copper
Conductor TypeStranded Conductor
RipcordYes
ArmorNo
Insulation MaterialPVC - Polyvinyl Chloride
Pair insulation nominal thickness0.018 in (0.46 mm)
Pair color codeBlack, White and Numbered
Comm wire insulation nominal thickness0.019 in (0.48 mm)
Comm Wire colorOrange
Individual pair shieldTape
Individual pair shield materialBi-Laminate (Alum+Poly)
Individual pair shield coverage100%
Individual pair drainwire22 AWG (7x30) TC
Overall shieldTape
Overall shield materialBi-Laminate (Alum+Poly)
Overall shield coverage100%
Overall drainwire20 AWG (7x28) TC
Shield TypeBoth individual and overall shields
Outer jacket materialPVC - Polyvinyl Chloride
Jacket ColorBlack
Outer jacket nominal thickness0.063 in (1.6 mm)
Overall cable diameter (nominal)0.704 in (17.9 mm)
Bulk cable weight286 lbs/1000ft
UL Voltage Rating300 V (CMG, PLTC, UL AWM 2464), 150 V (ITC)
Pair nominal Conductor DCR9.5 Ohm/1000ft (31 Ohm/km)
Pair nominal capacitance Cond-to-Cond30 pF/ft (98 pF/m)
Pair nominal capacitance (Cond-to-Shield)55 pF/ft (180 pF/m)
Pair nominal inductance0.19 µH/ft (0.62 µH/m)
Max. current3 Amps per Conductor @ 25°C
Comm Wire nominal Conductor DCR14.7 Ohm/1000ft (48.2 Ohm/km)
Nom. outer shield DCR6.5 Ohm/1000ft (21 Ohm/km)
UL temperature105°C
Operating temperature-30°C to +105°C
Bend radius (stationary min.)7.0 in (180 mm)
Bend radius (installation min.)7.0 in (180 mm)
Max Pull Tension617 lbs (280 kg)
Environmental suitabilityIndoor/Outdoor, Indoor, Outdoor, Sunlight Resistance
Flammability / reaction to fireUL1685 (FT4 Loading), FT4, T-29-520, 1202
NEC / UL complianceArticle 725, Article 727, Article 800, CMG, ITC, PLTC
AWM complianceAWM 2464
CEC / C(UL) complianceCMG
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC complianceChina RoHS II (GB/T 26572-2011)
UL instrumentation printUL instrumentation, 16 Pair 20+22AWG (7x28) Bare Copper, PVC Insulation E1 Color Code, Individual & Overall Beldfoil® Shield, Black PVC Outer Jacket, PLTC ITC CMG AWM 2464 SUN RES
Item TypeBelden Instrumentation Cable