Belden 1424A 060, Multi Conductor Computer Cable 12 Pair + 1 24 AWG

SKU:Belden 1424A 060
● Auf Lager
Beschreibung
Belden 1424A 060 is a multi-pair computer communications cable for EIA RS-232/422 and RS-423 signal transmission, including extended distance applications. It is built with 12 twisted pairs + 1 Conductor using 24 AWG stranded (7x32) TC - Tinned Copper and Datalene® insulation. An overall Beldfoil® shield with 100% coverage and a 24 AWG (7x32) TC drainwire help reduce EMI, and the PVC - Polyvinyl Chloride jacket is rated CM for indoor use.
Key Features
- 12 pair(s) + 1 Conductor construction supports multi-pair signal transmission in one cable.
- 24 AWG stranded (7x32) TC - Tinned Copper conductors support low-voltage analog and digital control signals.
- Overall shield with 100% coverage plus drainwire helps reduce EMI.
- PVC - Polyvinyl Chloride jacket with CM rating supports indoor installations.
Technical Specs
Construction & Materials
| Number of elements | 12 pair(s) + 1 Conductor |
|---|---|
| Conductor size | 24 AWG |
| Conductor stranding | 7x32 |
| Conductor material | TC - Tinned Copper |
| Conductor type | Stranded Conductor |
| Insulation material | Datalene® |
| Pair(s) insulation | PE - Polyethylene (Foam) |
| Nom. insulation thickness | 0.0125 in (0.318 mm) |
| Nom. insulation diameter | 0.049 in (1.2 mm) |
| Pair color code | Western Electric Standard |
| Conductor(s) color | Gray |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Shield construction | Overall Shield & drain |
| Drainwire | 24 AWG (7x32) TC |
| Jacket material | PVC - Polyvinyl Chloride |
| Nom. jacket thickness | 0.035 in (0.89 mm) |
Physical Dimensions & Weight
| Overall cable diameter (nominal) | 0.418 in (10.6 mm) |
|---|---|
| Bulk cable weight | 76 lbs/1000ft |
Performance & Electrical Characteristics
| Nom. conductor DCR (pair(s)) | 24 Ohm/1000ft |
|---|---|
| Nom. capacitance Cond-to-Cond | 13 pF/ft (43 pF/m) |
| Nom. capacitance Cond-to-other (conds + Shield) | 22 pF/ft (72 pF/m) |
| Nom. characteristic impedence | 100 Ohm |
| Nom. inductance | 0.213 μH/ft (0.699 μH/m) |
| Nom. velocity of prop. | 78% |
| Max. current | 1.8 Amps per Conductor at 25ºC |
| Nom outer Shield DCR | 12 Ohm/1000ft (39 Ohm/km) |
Environmental & Mechanical Ratings
| UL voltage rating | 300 V (CM), 30 V (UL AWM 2919) |
|---|---|
| Operating temperature | -20°C to +80°C |
| UL temperature | 80°C |
| Bend radius (stationary min.) | 2.9 in (74 mm) |
| Bend radius (installation min.) | 2.9 in (74 mm) |
| Max. pull tension | 138 lbs (62.6 kg) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor |
Compliance & Certifications
| NEC / UL compliance | Article 800, CM |
|---|---|
| CEC / C(UL) compliance | CM |
| AWM compliance | AWM 2919 |
| Flammability / reaction to fire | UL 1685 FT4 Loading |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Applications
- Designed for RS-232 extended distance applications.
- Suitable for RS-423 applications.
- Used in computer communications signal transmission.
- Supports low voltage analog signals (4-20ma, 0-10v, ...).
- Supports low voltage digital control (24v, …).
- Used for line level audio signal runs.
- Commonly installed for panel wiring in indoor environments.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Number of elements | 12 pair(s) + 1 Conductor |
| Conductor size | 24 AWG |
| Conductor stranding | 7x32 |
| Conductor Material | TC - Tinned Copper |
| Conductor Type | Stranded Conductor |
| Insulation Material | Datalene® |
| Pair(s) insulation | PE - Polyethylene (Foam) |
| Nom. insulation thickness | 0.0125 in (0.318 mm) |
| Nom. insulation diameter | 0.049 in (1.2 mm) |
| Pair color code | Western Electric Standard |
| Conductor(s) color | Gray |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield construction | Overall Shield & drain |
| Drain Wire | 24 AWG (7x32) TC |
| Jacket Material | PVC - Polyvinyl Chloride |
| Nom. jacket thickness | 0.035 in (0.89 mm) |
| Overall cable diameter (nominal) | 0.418 in (10.6 mm) |
| Bulk cable weight | 76 lbs/1000ft |
| Nom. Conductor DCR (pairs) | 24 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 13 pF/ft (43 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 22 pF/ft (72 pF/m) |
| Nom. characteristic impedence | 100 Ohm |
| Nom. inductance | 0.213 μH/ft (0.699 μH/m) |
| Nom. velocity of prop. | 78% |
| Max. current | 1.8 Amps per Conductor at 25ºC |
| Nom. outer shield DCR | 12 Ohm/1000ft (39 Ohm/km) |
| UL Voltage Rating | 300 V (CM), 30 V (UL AWM 2919) |
| Operating temperature | -20°C to +80°C |
| UL temperature | 80°C |
| Bend radius (stationary min.) | 2.9 in (74 mm) |
| Bend radius (installation min.) | 2.9 in (74 mm) |
| Max Pull Tension | 138 lbs (62.6 kg) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor |
| NEC / UL compliance | Article 800, CM |
| CEC / C(UL) compliance | CM |
| AWM compliance | AWM 2919 |
| Flammability / reaction to fire | UL 1685 FT4 Loading |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.