Kontakt1-800-975-3686
Ramcorp Wire & Cable

Belden 1474A 2 Paare 18 + 1/C 22 AWG SPOS PLTC-ER Schwarz PVC Mantel

Belden 1474A 010

SKU:Belden 1474A

$348.00

Auf Lager

Beschreibung

Spezifikationen

Belden 1474A 2 Paare 18 + 1/C 22 AWG SPOS PLTC-ER Schwarz PVC Mantel specifications
AttributeValue
Conductor TypeStranded Conductor
Pair(s) insulationPVC - Polyvinyl Chloride, 0.019 in (0.48 mm) nominal thickness, 0.083 in (2.1 mm) nominal insulation diameter, ICEA Chart E1 color code
Comm wire insulationPVC - Polyvinyl Chloride, 0.019 in (0.48 mm) nominal thickness, 0.066 in (1.7 mm) nominal insulation diameter, Orange
Inner shield (pair(s))Tape, Bi-Laminate (Alum+Poly), 100% coverage, 20 AWG (7x28) TC drainwire, each pair
Outer shieldTape, Bi-Laminate (Alum+Poly), 100% coverage, 18 AWG (7x26) TC drainwire
Outer jacketPVC - Polyvinyl Chloride, 0.053 in (1.3 mm) nominal thickness, 0.443 in (11.3 mm) nominal diameter, Ripcord: Yes
ArmorNo
ThermocoupleNo
Overall cable diameter (nominal)0.443 in (11.3 mm)
Bulk cable weight85 lbs/1000ft
Nom. Conductor DCR (pairs)6.66 Ohm/1000ft
Nom. inner shield DCR (pair(s))8.48 Ohm/1000ft (27.8 Ohm/km)
Nom. capacitance cond-to-cond (pair(s))51 pF/ft (170 pF/m)
Nom. capacitance cond-to-other (conds + shield) (pair(s))92 pF/ft (300 pF/m)
Max. Current (pair(s))11 Amps per Conductor @ 30°C
Nom. conductor DCR (comm wire)17.2 Ohm/1000ft (56.4 Ohm/km)
Max. current (comm wire)9.6 Amps per Conductor @ 30°C
Nom. outer shield DCR6 Ohm/1000ft (20 Ohm/km)
UL temperature105°C
Operating temperature-30°C to +105°C
Bend radius (stationary min.)5.3 in (130 mm)
Bend radius (installation min.)5.3 in (130 mm)
Max Pull Tension134 lbs (60.8 kg)
NEC / UL complianceArticle 725, Article 727, Article 800, CMG, ITC, PLTC, CL3
AWM complianceAWM 2464
CEC / C(UL) complianceCMG
Flammability / reaction to fireUL 1685 FT4 Loading, FT4, T-29-520, IEEE 1202 FT4
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC complianceChina RoHS II (GB/T 26572-2011)
UL instrumentationPLTC ITC CMG AWM 2464 SUN RES
Item TypeBelden Instrumentation Cable
Priced PerFT

Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.

Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?

Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.