Kontakt1-800-975-3686
Ramcorp Wire & Cable

Belden 1492A 2 Paare 16 + 1/C 22 AWG SPOS PLTC-ER Schwarz PVC Mantel

Belden 1492A 010

SKU:Belden 1492A

$493.20

Auf Lager

Beschreibung

Spezifikationen

Belden 1492A 2 Paare 16 + 1/C 22 AWG SPOS PLTC-ER Schwarz PVC Mantel specifications
AttributeValue
Pairs2
Comm Wire(s)1
Conductor TypeStranded conductor
Pair Conductor Size16 AWG
Pair Stranding7x24
Pair Conductor MaterialBC - Bare Copper
Comm Wire size22 AWG
Comm Wire stranding7x30
Comm Wire materialBC - Bare Copper
Pair insulation materialPVC - Polyvinyl Chloride
Pair nominal insulation thickness0.019 in (0.48 mm)
Pair nominal Insulation Diameter0.095 in (2.4 mm)
Pair color codeICEA Chart E1
Comm wire insulation materialPVC - Polyvinyl Chloride
Comm wire nominal insulation thickness0.019 in (0.48 mm)
Comm wire nominal insulation diameter0.066 in (1.7 mm)
Comm Wire colorOrange
Inner shield (each pair)Tape, Bi-Laminate (Alum+Poly), 100%
Inner shield drainwire18 AWG (7x26) TC
Outer shieldTape, Bi-Laminate (Alum+Poly), 100%
Outer shield drainwire16 AWG (7x24) TC
Nominal jacket thickness0.053 in (1.3 mm)
Overall cable diameter (nominal)0.476 in (12.1 mm)
RipcordYes
ArmorNo
Pair nominal Conductor DCR4.2 Ohm/1000ft
Pair nominal inner Shield DCR5.58 Ohm/1000ft (18.3 Ohm/km)
Nom. outer shield DCR3.3 Ohm/1000ft (11 Ohm/km)
Pair nominal capacitance Cond-to-Cond60 pF/ft (200 pF/m)
Pair nominal capacitance Cond-to-other (Conds + Shield)110 pF/ft (360 pF/m)
Max. Current (pair(s))14 Amps per Conductor @ 30°C
Comm Wire nominal Conductor DCR17.2 Ohm/1000ft (56.4 Ohm/km)
Max. current (comm wire)9.6 Amps per Conductor @ 30°C
Operating temperature-30°C to +105°C
UL temperature105°C
Bend radius (stationary min.)5.7 in (140 mm)
Bend radius (installation min.)5.7 in (140 mm)
Max Pull Tension210 lbs (95 kg)
Bulk cable weight115 lbs/1000ft
Environmental suitabilityIndoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial
NEC / UL complianceArticle 725, Article 727, Article 800, CMG, ITC, PLTC
AWM complianceAWM 2464
CEC / C(UL) complianceCMG
Flammability / reaction to fireUL 1685 FT4 Loading, FT4, IEEE 1202 FT4
Ratings & MarkingsPLTC ITC CMG AWM 2464 SUN RES
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC complianceChina RoHS II (GB/T 26572-2011)
UL instrumentationUL instrumentation
Priced PerFT
Item TypeBelden Instrumentation Cable

Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.

Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?

Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.