Kontakt1-800-975-3686
Ramcorp Wire & Cable

Belden 1495A 12 Paare 16 + 1/C 22 AWG SPOS PLTC-ER Schwarz PVC Mantel

Belden 1495A 010

SKU:Belden 1495A

$1,831.20

Auf Lager

Beschreibung

Spezifikationen

Belden 1495A 12 Paare 16 + 1/C 22 AWG SPOS PLTC-ER Schwarz PVC Mantel specifications
AttributeValue
Pairs12
Pair Conductor Size16 AWG
Pair Stranding7x24
Pair Conductor MaterialBC - Bare Copper
Comm Wire(s)1
Comm Wire size22 AWG
Comm Wire stranding7x30
Comm Wire materialBC - Bare Copper
Conductor TypeStranded Conductor
Insulation MaterialPVC - Polyvinyl Chloride
Pair(s) insulation thickness0.017 in (0.43 mm)
Pair(s) color codeBlack, White and Numbered
Comm Wire insulation thickness0.019 in (0.48 mm)
Comm Wire colorOrange
Individual pair shield typeTape
Individual pair shield materialBi-Laminate (Alum+Poly)
Individual pair shield coverage100%
Individual pair drainwire18 AWG (7x26) TC
Overall shield typeTape
Overall shield materialBi-Laminate (Alum+Poly)
Overall shield coverage100%
Overall drainwire16 AWG (7x24) TC
Comm wire shieldNo Shield
Jacket ColorBlack
Outer jacket thickness0.063 in (1.6 mm)
Overall cable diameter (nominal)0.840 in (21.3 mm)
RipcordYes
ArmorNo
Bulk cable weight447 lbs/1000ft
Pair(s) nominal conductor DCR3.67 Ohm/1000ft (12.0 Ohm/km)
Pair(s) nominal capacitance cond-to-cond60 pF/ft (200 pF/m)
Pair(s) nominal capacitance cond-to-other (conds + Shield)110 pF/ft (360 pF/m)
Comm wire(s) nominal conductor DCR14.7 Ohm/1000ft (48.2 Ohm/km)
Nom. outer shield DCR2.89 Ohm/1000ft (9.48 Ohm/km)
UL temperature105°C
Operating temperature-30°C to +105°C
Bend radius (stationary min.)8.4 in (210 mm)
Bend radius (installation min.)8.4 in (210 mm)
Max Pull Tension1170 lbs (531 kg)
Environmental suitabilityIndoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial
NEC / UL complianceArticle 725, Article 727, Article 800, CMG, ITC, PLTC
AWM complianceAWM 2464
CEC / C(UL) complianceCMG
Flammability / reaction to fireUL1685 (FT4 Loading), FT4, 1202
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC complianceChina RoHS II (GB/T 26572-2011)
Additional markings/ratingsPLTC ITC CMG AWM 2464 SUN RES
Item TypeBelden Instrumentation Cable
Priced PerFT

Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.

Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?

Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.