Kontakt1-800-975-3686
Ramcorp Wire & Cable

Belden 1505A 006 SDI Koax RG-59 20 AWG BC CMR hellblau

Belden 1505A 006 SDI Koax RG-59 20 AWG BC CMR hellblau

SKU:Belden 1505A 006

Angebot anfordern

Angebot anfordern

Beschreibung

Spezifikationen

Belden 1505A 006 SDI Koax RG-59 20 AWG BC CMR hellblau specifications
AttributeValue
Coax constructionCoaxial
Conductor20 AWG, Solid, 0.032 in, BC - Bare Copper
InsulationPE - Polyethylene (Foam), 0.145 in (3.68 mm), White
Outer shield layer 1Tape, Tri-Laminate (Alum+Poly+Alum), Duofoil®, 100%
Outer shield layer 2Braid, Tinned Copper (TC), 95%
JacketPVC - Polyvinyl Chloride, 0.233 in (5.92 mm)
Jacket ColorBlue
Overall cable diameter (nominal)0.233 in (5.92 mm)
Bulk cable weight31 lbs/1000ft (46 kg/km)
FloodedNo not flooded over braid
OutdoorNo not outdoor grade material
Environmental suitabilityIndoor, Indoor, Aerial - Black only, When supported by messenger Wire
Plenum number1506A
Nom. velocity of prop.82%
Nom. capacitance (Cond-to-Shield)16.3 pF/ft (53.5 pF/m)
Nom. conductor DCR10 Ohm/1000ft (33 Ohm/km)
Nom. outer shield DCR3.8 Ohm/1000ft (12 Ohm/km)
Return loss5 - 1600 MHz: 23 dB; 1600 - 4500 MHz: 21 dB; 4500 - 6000 MHz: 15 dB
Attenuation (Nominal)1 MHz: 0.3 dB/100ft; 3.58 MHz: 0.6 dB/100ft; 5 MHz: 0.63 dB/100ft; 6 MHz: 0.69 dB/100ft; 7 MHz: 0.74 dB/100ft; 10 MHz: 0.9 dB/100ft; 12 MHz: 0.91 dB/100ft; 25 MHz: 1.3 dB/100ft; 67.5 MHz: 2.05 dB/100ft; 71.5 MHz: 2.1 dB/100ft; 88.5 MHz: 2.2 dB/100ft; 100 MHz: 2.3 dB/100ft; 135 MHz: 2.7 dB/100ft; 143 MHz: 2.8 dB/100ft; 180 MHz: 3.1 dB/100ft; 270 MHz: 3.8 dB/100ft; 360 MHz: 4.4 dB/100ft; 540 MHz: 5.5 dB/100ft; 720 MHz: 6.4 dB/100ft; 750 MHz: 6.5 dB/100ft; 1000 MHz: 7.6 dB/100ft; 1500 MHz: 9.3 dB/100ft; 2000 MHz: 10.9 dB/100ft; 2250 MHz: 11.6 dB/100ft; 3000 MHz: 13.4 dB/100ft; 4500 MHz: 17.5 dB/100ft; 6000 MHz: 21.1 dB/100ft
UL temperature60°C
Operating temperature-30°C to +75°C
Installation min. bend radius2.3 in (58 mm)
Max Pull Tension52 lbs (24 kg)
NEC / UL complianceCMR
CEC / C(UL) complianceCMG
Fire ratingRiser
Flammability / reaction to fireUL1666 Vertical Shaft
CPR complianceCPR Euroclass: Eca; CPR UKCA Class: Eca
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK regulation complianceUKCA Mark
APAC complianceChina RoHS II (GB/T 26572-2011)
SustainabilityCA Prop 65
Item TypeBelden Coaxial Cable RG59
Priced PerFT

Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.

Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?

Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.