Kontakt1-800-975-3686
Ramcorp Wire & Cable

Belden 1505A 008 SDI Koax RG-59 20 AWG BC CMR grau

Belden 1505A 008 SDI Koax RG-59 20 AWG BC CMR grau

SKU:Belden 1505A 008

Angebot anfordern

Angebot anfordern

Beschreibung

Spezifikationen

Belden 1505A 008 SDI Koax RG-59 20 AWG BC CMR grau specifications
AttributeValue
Coax constructionCoaxial
Coax TypeRG 59
RG type59
Conductor size20 AWG
Conductor diameter (nom.)0.032 in
Conductor MaterialBC - Bare Copper
Insulation MaterialPE - Polyethylene (Foam)
Insulation diameter (nom.)0.145 in (3.68 mm)
Insulation color codeWhite
Jacket diameter (nom.)0.233 in (5.92 mm)
Overall cable diameter (nominal)0.233 in (5.92 mm)
Bulk cable weight31 lbs/1000ft (46 kg/km)
Plenum number1506A
Conductor DCR (nom.)10 Ohm/1000ft (33 Ohm/km)
Outer shield DCR (nom)3.8 Ohm/1000ft (12 Ohm/km)
Capacitance Cond-to-Shield (nom.)16.3 pF/ft (53.5 pF/m)
Velocity of propagation (nom.)82%
Return loss5 - 1600 MHz: 23 dB (min.); 1600 - 4500 MHz: 21 dB (min.); 4500 - 6000 MHz: 15 dB (min.)
Attenuation (nom.)1 MHz: 0.3 dB/100ft; 3.58 MHz: 0.6 dB/100ft; 5 MHz: 0.63 dB/100ft; 6 MHz: 0.69 dB/100ft; 7 MHz: 0.74 dB/100ft; 10 MHz: 0.9 dB/100ft; 12 MHz: 0.91 dB/100ft; 25 MHz: 1.3 dB/100ft; 67.5 MHz: 2.05 dB/100ft; 71.5 MHz: 2.1 dB/100ft; 88.5 MHz: 2.2 dB/100ft; 100 MHz: 2.3 dB/100ft; 135 MHz: 2.7 dB/100ft; 143 MHz: 2.8 dB/100ft; 180 MHz: 3.1 dB/100ft; 270 MHz: 3.8 dB/100ft; 360 MHz: 4.4 dB/100ft; 540 MHz: 5.5 dB/100ft; 720 MHz: 6.4 dB/100ft; 750 MHz: 6.5 dB/100ft; 1000 MHz: 7.6 dB/100ft; 1500 MHz: 9.3 dB/100ft; 2000 MHz: 10.9 dB/100ft; 2250 MHz: 11.6 dB/100ft; 3000 MHz: 13.4 dB/100ft; 4500 MHz: 17.5 dB/100ft; 6000 MHz: 21.1 dB/100ft
UL temperature60°C
Operating temperature-30°C to +75°C
Installation min. bend radius2.3 in (58 mm)
Max Pull Tension52 lbs (24 kg)
Flammability / reaction to fireUL1666 Vertical Shaft
Environmental suitabilityIndoor, Indoor, Aerial - Black only, When supported by messenger Wire
CPR complianceCPR Euroclass: Eca; CPR UKCA Class: Eca
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK regulation complianceUKCA Mark
APAC complianceChina RoHS II (GB/T 26572-2011)
SustainabilityCA Prop 65
Item TypeBelden Coaxial Cable RG59
Priced PerFT

Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.

Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?

Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.