Belden 1530A 010, Coax CATV Cable 18 AWG FR PVC Black

SKU:Belden 1530A 010
● Auf Lager
Beschreibung
Belden 1530A 010 is a Series 6 (RG 6) CATV coaxial cable with 75 Ohm nominal characteristic impedance for indoor general-purpose installations. It features an 18 AWG solid BCCS - Bare Copper Covered Steel conductor and PE - Polyethylene (Foam) insulation with Gas Injected construction. Shielding includes Tape, Tri-Laminate (Alum+Poly+Alum), Duoofoil®, 100% plus an Aluminum braid at 90% coverage. A black PVC - Polyvinyl Chloride jacket and NEC/(UL) compliance: CATV, CM support standard indoor routing requirements.
Belden 1530A 010 Key Features
- Series 6 (RG 6) coaxial construction with 1 coax and 1 conductor.
- 75 Ohm nominal characteristic impedance for CATV signal transmission.
- 18 AWG solid BCCS - Bare Copper Covered Steel conductor with 0.04 in nominal diameter.
- PE - Polyethylene (Foam) insulation with Gas Injected construction and 0.18 in nominal diameter.
- Dual-layer shielding: Tape, Tri-Laminate (Alum+Poly+Alum), Duoofoil®, 100% plus braid, Aluminum, 90%.
- Black PVC - Polyvinyl Chloride jacket with 0.27 in nominal diameter.
- NEC/(UL) compliance: CATV, CM; CEC/C(UL) compliance: CM; CPR Euroclass: Eca.
- UL voltage rating: 350 V RMS.
- Operating temperature range: -40°C to +80°C; UL temperature rating: 80°C.
Belden 1530A 010 Technical Specs
Performance & Electrical Characteristics
| Nominal capacitance (Conductor to Shield) | 16.2 pF/ft |
|---|---|
| Nominal inductance | 0.097 μH/ft |
| Nominal delay | 1.2 ns/ft |
| Nominal velocity of propagation (VP) | 83% |
| Return loss | 5 - 1000 MHz, 20 dB (min. structural return loss (SRL)) |
| Nominal Conductor DCR | 28 Ohm/1000ft |
| Nominal outer Shield DCR | 5 Ohm/1000ft |
| Outer Conductor DCR | 5 Ohm/1000ft |
Max. Insertion Loss (Attenuation)
| Max. insertion loss (attenuation) | 5 MHz, 0.58 dB/100ft |
|---|---|
| Max. insertion loss (attenuation) | 55 MHz, 1.60 dB/100ft |
| Max. insertion loss (attenuation) | 211 MHz, 3.05 dB/100ft |
| Max. insertion loss (attenuation) | 270 MHz, 3.37 dB/100ft |
| Max. insertion loss (attenuation) | 300 MHz, 3.55 dB/100ft |
| Max. insertion loss (attenuation) | 350 MHz, 3.85 dB/100ft |
| Max. insertion loss (attenuation) | 400 MHz, 4.15 dB/100ft |
| Max. insertion loss (attenuation) | 450 MHz, 4.40 dB/100ft |
| Max. insertion loss (attenuation) | 550 MHz, 4.90 dB/100ft |
| Max. insertion loss (attenuation) | 750 MHz, 5.65 dB/100ft |
| Max. insertion loss (attenuation) | 870 MHz, 6.11 dB/100ft |
| Max. insertion loss (attenuation) | 1000 MHz, 6.55 dB/100ft |
Physical & Mechanical Ratings
| Bulk Cable Weight | 28 lbs/1000ft |
|---|---|
| Maximum recommended pulling tension | 162 lbs |
| Minimum minor axis Bend Radius | 2.75 in |
Environmental & Installation
| UL flammability | UL1685 UL Loading |
|---|---|
| Environmental space | Indoor (Not Riser or Plenum) |
| Suitability - indoor | Yes |
| Plenum (Y/N) | No |
| Plenum number | 1530AP |
Compliance & Directives
| EU Directive 2000/53/EC (ELV) | Yes |
|---|---|
| EU Directive 2003/96/EC (BFR) | Yes |
| EU Directive 2011/65/EU (RoHS 2) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
| EU CE Mark | No |
| MII Order #39 (China RoHS) | Yes |
Belden 1530A 010 Applications
- Use it for indoor general-purpose installations where CATV coaxial cabling is required.
- Install it in Indoor (Not Riser or Plenum) environments, with Plenum (Y/N): No.
- Meet CATV and CM compliant installation contexts per NEC/(UL) compliance: CATV, CM and CEC/C(UL) compliance: CM.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Nominal capacitance (conductor-to-shield) | 16.2 pF/ft |
| Nominal inductance | 0.097 µH/ft |
| Nominal delay | 1.2 ns/ft |
| Nominal velocity of propagation (VP) [%] | 83% |
| Return loss | 5 - 1000 MHz, 20 dB (min. structural return loss (SRL)) |
| Nominal conductor DCR | 28 Ohm/1000ft |
| Nominal outer shield DCR | 5 Ohm/1000ft |
| Outer conductor DCR | 5 Ohm/1000ft |
| Max. insertion loss (attenuation) | 5 MHz, 0.58 dB/100ft; 55 MHz, 1.60 dB/100ft; 211 MHz, 3.05 dB/100ft; 270 MHz, 3.37 dB/100ft; 300 MHz, 3.55 dB/100ft; 350 MHz, 3.85 dB/100ft; 400 MHz, 4.15 dB/100ft; 450 MHz, 4.40 dB/100ft; 550 MHz, 4.90 dB/100ft; 750 MHz, 5.65 dB/100ft; 870 MHz, 6.11 dB/100ft; 1000 MHz, 6.55 dB/100ft |
| Bulk cable weight | 28 lbs/1000ft |
| Maximum recommended pulling tension | 162 lbs |
| Minimum minor axis bend radius | 2.75 in |
| UL flammability | UL1685 UL Loading |
| Environmental space | Indoor (Not Riser or Plenum) |
| Suitability - indoor | Yes |
| Plenum (Y/N) | No |
| Plenum number | 1530AP |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2003/96/EC (BFR) | Yes |
| EU Directive 2011/65/EU (RoHS 2) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
| EU directive compliance | EU Directive 2003/11/EC (BFR) |
| EU CE mark | No |
| MII Order #39 (China RoHS) | Yes |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.