Belden 1617A 009, RG11 14 SOLID SS FPE Shield PV White 75 OHM

SKU:Belden 1617A 009
● Auf Lager
Beschreibung
Belden 1617A 009 is a Series 11 RG 11 coaxial cable designed for broadband, CATV, RF drop cable, and Over-The-Air (OTA) antenna runs requiring 75 Ohm performance. It uses a 14 AWG solid BCCS - Bare Copper Covered Steel conductor with PE - Polyethylene (Foam) insulation and a PVC - Polyvinyl Chloride jacket. The Quad Shield (F/B+F/B) construction combines foil and aluminum braid layers to help reduce interference. It is CM rated with a UL voltage rating of 300 V (CM) for indoor general-purpose installations.
Key Features
- Series 11 RG 11 coaxial construction for broadband and CATV signal distribution.
- 75 Ohm nominal characteristic impedance for consistent coax performance.
- Quad Shield (F/B+F/B) design with foil and aluminum braid layers to help reduce interference.
- 14 AWG solid BCCS - Bare Copper Covered Steel conductor with PE - Polyethylene (Foam) insulation.
- PVC - Polyvinyl Chloride jacket with CM rating and UL voltage rating of 300 V (CM).
Technical Specs
Product Identification
| Part number | 1617A 009 |
|---|---|
| Brand | Belden |
| Coax type | RG 11 |
| Series type | 11 |
| Plenum number | 1617AP |
Construction & Physical Specs
| Overall cable diameter (nominal) | 0.407 in (10.3 mm) |
|---|---|
| Conductor nominal diameter | 0.064 in |
| Nom. insulation diameter | 0.280 in (7.11 mm) |
| Insulation color code | White |
| Shield type | Quad Shield (F/B+F/B) |
| Shield layer 1 | Tape, Tri-Laminate (Alum+Poly+Alum), Duobond® II, 100% |
| Shield layer 2 | Braid, Aluminum, 60% |
| Shield layer 3 | Tape, Tri-Laminate (Alum+Poly+Alum), Duofoil®, 100% |
| Shield layer 4 | Braid, Aluminum, 40% |
| Bulk cable weight | 60 lbs/1000ft |
Performance & Electrical Characteristics
| Nom. velocity of prop. | 83% |
|---|---|
| Nom. capacitance Cond-to-Shield | 16.3 pF/ft (53.5 pF/m) |
| Nom. conductor DCR | 12 Ohm/1000ft |
| Nom. outer shield DCR | 3 Ohm/1000ft (9.8 Ohm/km) |
| Return loss | 5 - 1000 MHz: 20 dB (min. structural return loss) |
| Attenuation (Max.) | 5 MHz: 0.38 dB/100ft; 55 MHz: 0.96 dB/100ft; 211 MHz: 1.90 dB/100ft; 250 MHz: 2.05 dB/100ft; 270 MHz: 2.13 dB/100ft; 300 MHz: 2.25 dB/100ft; 330 MHz: 2.35 dB/100ft; 350 MHz: 2.42 dB/100ft; 400 MHz: 2.60 dB/100ft; 450 MHz: 2.75 dB/100ft; 500 MHz: 2.90 dB/100ft; 550 MHz: 3.04 dB/100ft; 600 MHz: 3.18 dB/100ft; 750 MHz: 3.65 dB/100ft; 870 MHz: 4.06 dB/100ft; 1000 MHz: 4.35 dB/100ft |
Environmental & Mechanical Ratings
| Operating | -40°C to +75°C |
|---|---|
| UL temperature | 75°C |
| Installation min. bend radius | 4.1 in (100 mm) |
| Max. pull tension | 308 lbs (140 kg) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor, Aerial - Black only, When supported by messenger Wire |
Compliance & Certifications
| NEC / UL compliance | CM, CATV |
|---|---|
| CEC / C(UL) compliance | CM |
| Flammability / reaction to fire | UL1685 UL Loading |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | ANSI/SCTE 74 |
| Sustainability | CA Prop 65 |
Applications
- Supports broadband distribution where stable coax performance is required.
- Used for Cable Television (CATV) signal runs.
- Fits RF drop cable installations.
- Connects Over-The-Air (OTA) antenna feeds to equipment.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Coax Type | RG 11 |
| Series type | 11 |
| Plenum number | 1617AP |
| Overall cable diameter (nominal) | 0.407 in (10.3 mm) |
| Conductor nominal diameter | 0.064 in |
| Nom. insulation diameter | 0.280 in (7.11 mm) |
| Insulation color code | White |
| Shield Type | Quad Shield (F/B+F/B) |
| Shield layer 1 | Tape, Tri-Laminate (Alum+Poly+Alum), Duobond® II, 100% |
| Shield layer 2 | Braid, Aluminum, 60% |
| Shield layer 3 | Tape, Tri-Laminate (Alum+Poly+Alum), Duofoil®, 100% |
| Shield layer 4 | Braid, Aluminum, 40% |
| Bulk cable weight | 60 lbs/1000ft |
| Nom. velocity of prop. | 83% |
| Nom. capacitance (Cond-to-Shield) | 16.3 pF/ft (53.5 pF/m) |
| Nom. conductor DCR | 12 Ohm/1000ft |
| Nom. outer shield DCR | 3 Ohm/1000ft (9.8 Ohm/km) |
| Return loss | 5 - 1000 MHz: 20 dB (min. structural return loss) |
| Attenuation (Max.) | 5 MHz: 0.38 dB/100ft; 55 MHz: 0.96 dB/100ft; 211 MHz: 1.90 dB/100ft; 250 MHz: 2.05 dB/100ft; 270 MHz: 2.13 dB/100ft; 300 MHz: 2.25 dB/100ft; 330 MHz: 2.35 dB/100ft; 350 MHz: 2.42 dB/100ft; 400 MHz: 2.60 dB/100ft; 450 MHz: 2.75 dB/100ft; 500 MHz: 2.90 dB/100ft; 550 MHz: 3.04 dB/100ft; 600 MHz: 3.18 dB/100ft; 750 MHz: 3.65 dB/100ft; 870 MHz: 4.06 dB/100ft; 1000 MHz: 4.35 dB/100ft |
| Operating | -40°C to +75°C |
| UL temperature | 75°C |
| Installation min. bend radius | 4.1 in (100 mm) |
| Max Pull Tension | 308 lbs (140 kg) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor, Aerial - Black only, When supported by messenger Wire |
| NEC / UL compliance | CM, CATV |
| CEC / C(UL) compliance | CM |
| Flammability / reaction to fire | UL1685 UL Loading |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | ANSI/SCTE 74 |
| Sustainability | CA Prop 65 |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.