Belden 1617A 010, Coax CATV Cable 14 AWG DBL SH PVC Black

SKU:Belden 1617A 010
● Auf Lager
Beschreibung
Belden 1617A 010 is a Series 11 broadband coax cable (RG 11) built with a 14 AWG solid BCCS - Bare Copper Covered Steel conductor, PE - Polyethylene (Foam) insulation, and a black PVC - Polyvinyl Chloride jacket. It uses a Quad Shield (F/B+F/B) design with foil and aluminum braid layers (60% and 40% coverage) to help reduce interference. This 75 Ohm coax is rated CM and includes a UL voltage rating of 300 V (CM). Environmental suitability is listed for indoor (not riser or plenum) and indoor, aerial - black only, when supported by messenger wire.
Belden 1617A 010 Key Features
- This is a Series 11 broadband coax cable (RG 11) with coaxial construction.
- It features a 14 AWG solid BCCS - Bare Copper Covered Steel conductor with a 0.064 in nominal conductor diameter.
- PE - Polyethylene (Foam) insulation provides a 0.280 in (7.11 mm) nominal insulation diameter and a white insulation color code.
- Quad Shield (F/B+F/B) construction combines tri-laminate tape layers and aluminum braid layers to help reduce interference.
- A black PVC - Polyvinyl Chloride jacket provides a 0.407 in (10.3 mm) nominal overall cable diameter.
- The cable has 75 Ohm nominal characteristic impedance with 83% nominal velocity of prop.
- It is rated CM, CATV with UL voltage rating: 300 V (CM).
Belden 1617A 010 Technical Specs
Construction & Shielding
| Shield layer 1 | Tape, Tri-Laminate (Alum+Poly+Alum), Duobond® II, 100% |
|---|---|
| Shield layer 2 | Braid, Aluminum, 60% |
| Shield layer 3 | Tape, Tri-Laminate (Alum+Poly+Alum), Duofoil®, 100% |
| Shield layer 4 | Braid, Aluminum, 40% |
Electrical Characteristics
| Nominal capacitance (Cond-to-Shield) | 16.3 pF/ft (53.5 pF/m) |
|---|---|
| Nominal conductor DCR | 12 Ohm/1000ft |
| Nominal outer shield DCR | 3 Ohm/1000ft (9.8 Ohm/km) |
Performance
| Return loss | 5 - 1000 MHz: 20 dB (min. structural return loss) |
|---|---|
| Attenuation (Max.) | 5 MHz: 0.38 dB/100ft; 55 MHz: 0.96 dB/100ft; 211 MHz: 1.90 dB/100ft; 250 MHz: 2.05 dB/100ft; 270 MHz: 2.13 dB/100ft; 300 MHz: 2.25 dB/100ft; 330 MHz: 2.35 dB/100ft; 350 MHz: 2.42 dB/100ft; 400 MHz: 2.60 dB/100ft; 450 MHz: 2.75 dB/100ft; 500 MHz: 2.90 dB/100ft; 550 MHz: 3.04 dB/100ft; 600 MHz: 3.18 dB/100ft; 750 MHz: 3.65 dB/100ft; 870 MHz: 4.06 dB/100ft; 1000 MHz: 4.35 dB/100ft |
Environmental & Mechanical Ratings
| Operating temperature | -40°C to +75°C |
|---|---|
| UL temperature | 75°C |
| Installation min. bend radius | 4.1 in (100 mm) |
| Max. pull tension | 308 lbs (140 kg) |
| Bulk cable weight | 60 lbs/1000ft |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor, Aerial - Black only, When supported by messenger Wire |
Compliance & Certifications
| NEC / UL compliance | CM, CATV |
|---|---|
| CEC / C(UL) compliance | CM |
| Flammability / reaction to fire | UL1685 UL Loading |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | ANSI/SCTE 74 |
| Sustainability | CA Prop 65 |
| Plenum number | 1617AP |
Belden 1617A 010 Applications
- Use it for broadband signal distribution where a Series 11 coax format is specified.
- For Cable Television (CATV) installations, it supports applications that call for CM, CATV compliant coax.
- In RF drop cable runs, quad-shield construction is used to help reduce interference.
- For Over-The-Air (OTA) antennas, it carries RF signals between antenna and equipment.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Shield layer 1 | Tape, Tri-Laminate (Alum+Poly+Alum), Duobond® II, 100% |
| Shield layer 2 | Braid, Aluminum, 60% |
| Shield layer 3 | Tape, Tri-Laminate (Alum+Poly+Alum), Duofoil®, 100% |
| Shield layer 4 | Braid, Aluminum, 40% |
| Nominal Capacitance (Cond-to-Shield) | 16.3 pF/ft (53.5 pF/m) |
| Nominal conductor DCR | 12 Ohm/1000ft |
| Nominal outer shield DCR | 3 Ohm/1000ft (9.8 Ohm/km) |
| Return loss | 5 - 1000 MHz: 20 dB (min. structural return loss) |
| Attenuation (Max.) | 5 MHz: 0.38 dB/100ft; 55 MHz: 0.96 dB/100ft; 211 MHz: 1.90 dB/100ft; 250 MHz: 2.05 dB/100ft; 270 MHz: 2.13 dB/100ft; 300 MHz: 2.25 dB/100ft; 330 MHz: 2.35 dB/100ft; 350 MHz: 2.42 dB/100ft; 400 MHz: 2.60 dB/100ft; 450 MHz: 2.75 dB/100ft; 500 MHz: 2.90 dB/100ft; 550 MHz: 3.04 dB/100ft; 600 MHz: 3.18 dB/100ft; 750 MHz: 3.65 dB/100ft; 870 MHz: 4.06 dB/100ft; 1000 MHz: 4.35 dB/100ft |
| Operating temperature | -40°C to +75°C |
| UL temperature | 75°C |
| Installation min. bend radius | 4.1 in (100 mm) |
| Max Pull Tension | 308 lbs (140 kg) |
| Bulk cable weight | 60 lbs/1000ft |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor, Aerial - Black only, When supported by messenger Wire |
| NEC / UL compliance | CM, CATV |
| CEC / C(UL) compliance | CM |
| Flammability / reaction to fire | UL1685 UL Loading |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | ANSI/SCTE 74 |
| Sustainability | CA Prop 65 |
| Plenum number | 1617AP |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.