Kontakt1-800-975-3686
Ramcorp Wire & Cable

Belden 1617AP 009, RG11 CATV 75 PVC Black Shielded 14 Solid SSC

Belden 1617AP 009, RG11 CATV 75 PVC Black Shielded 14 Solid SSC

SKU:Belden 1617AP 009

$4.24/ FT

Auf Lager

Beschreibung

Spezifikationen

Belden 1617AP 009, RG11 CATV 75 PVC Black Shielded 14 Solid SSC specifications
AttributeValue
Coax constructionCoaxial
Coax TypeRG 11
Series type11
Conductor size14 AWG
Conductor strandingSolid
Conductor MaterialBCCS - Bare Copper Covered Steel
Conductor nominal diameter0.064 in
Insulation MaterialFEP - Fluorinated Ethylene Propylene (Foam)
Insulation nominal diameter0.274 in (6.96 mm)
Insulation color codeWhite
Shield TypeQuad Shield (F/B+F/B)
Shield layer 1Tape, Tri-Laminate (Alum+Poly+Alum), Duobond® II, 100%
Shield layer 2Braid, Aluminum, 60%
Shield layer 3Tape, Tri-Laminate (Alum+Poly+Alum), Duofoil®, 100%
Shield layer 4Braid, Aluminum, 40%
Outer jacket materialPVDF - Polyvinylidene Fluoride
Nominal jacket diameter0.372 in (9.45 mm)
Overall cable diameter (nominal)0.372 in (9.45 mm)
Characteristic impedance (nom.)75 Ohm
Velocity of propagation (nom.)83%
Capacitance Cond-to-Shield (nom.)16.3 pF/ft (53.5 pF/m)
Conductor DCR (nom.)12 Ohm/1000ft
Outer shield DCR (nom)3 Ohm/1000ft (9.8 Ohm/km)
UL Voltage Rating300 V (CMP)
Return loss5 - 1000 MHz: 20 dB (min. structural return loss); 1000 - 2250 MHz: 15 dB (min. structural return loss)
Attenuation (Max.)5 MHz: 0.38 dB/100ft; 55 MHz: 0.96 dB/100ft; 211 MHz: 1.90 dB/100ft; 240 MHz: 2.43 dB/100ft; 270 MHz: 2.59 dB/100ft; 300 MHz: 2.75 dB/100ft; 325 MHz: 2.92 dB/100ft; 350 MHz: 3.08 dB/100ft; 400 MHz: 3.34 dB/100ft; 450 MHz: 3.64 dB/100ft; 500 MHz: 3.92 dB/100ft; 550 MHz: 4.19 dB/100ft; 600 MHz: 4.48 dB/100ft; 750 MHz: 5.31 dB/100ft; 870 MHz: 5.86 dB/100ft; 1000 MHz: 6.53 dB/100ft
Operating temperature-20°C to +150°C
UL temperature150°C
Installation min. bend radius3.7 in (94 mm)
Max Pull Tension308 lbs (140 kg)
Bulk cable weight63 lbs/1000ft
Environmental suitabilityIndoor - Plenum, Indoor, Aerial - Black only, When supported by messenger Wire
Fire ratingCMP
Flammability / reaction to fireNFPA 262
CEC / C(UL) complianceCMP
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC complianceChina RoHS II (GB/T 26572-2011)
SustainabilityCA Prop 65
Non-Plenum number1617A, 7999A
Priced PerFT

Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.

Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?

Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.