Belden 1694A 007, RG6 18 Solid BC Duofoil+95% PVC Jacket CMR ROHS, Violet Jacket

SKU:Belden 1694A 007
● Auf Lager
Beschreibung
Belden 1694A 007 is a 75 Ohm SDI coax in the RG-6 format designed for digital video transmission, including 6 Gb/s UHDTV and HD-SDI 1080p. It features an 18 AWG solid BC - Bare Copper conductor with PE - Polyethylene (Foam) insulation. Shielding is provided by Duofoil® tri-laminate tape plus a 95% Tinned Copper braid, and the cable is finished with a PVC - Polyvinyl Chloride jacket in Violet. It carries a CMR rating and a 300 V (CMR, CMG) UL Voltage Rating.
Belden 1694A 007 Key Features
- 75 Ohm characteristic impedance for SDI coax applications.
- RG-6 coax construction with an 18 AWG solid BC - Bare Copper conductor.
- PE - Polyethylene (Foam) insulation with White color code.
- Shielding includes Duofoil® tri-laminate tape (100% coverage) plus a Tinned Copper (TC) braid (95% coverage).
- PVC - Polyvinyl Chloride jacket in Violet with CMR and CMG compliance and a 300 V (CMR, CMG) UL Voltage Rating.
Belden 1694A 007 Technical Specs
Construction & Physical Specs
| Coax construction | Coaxial |
|---|---|
| Coax type | RG-6 |
| RG type | 6 |
| Overall cable diameter (nominal) | 0.274 in (6.96 mm) |
| Conductor nom. diameter | 0.040 in |
| Nom. insulation diameter | 0.180 in (4.57 mm) |
| Shield type | Both, braid over foil |
| Flooded | No not flooded over braid |
| Jacket nom. diameter | 0.274 in (6.96 mm) |
| Outdoor | No not outdoor grade material |
| Bulk cable weight | 41 lbs/1000ft (61 kg/km) |
| Plenum number | 1695A |
Electrical Characteristics
| Nom. conductor DCR | 6.4 Ohm/1000ft (21 Ohm/km) |
|---|---|
| Nom. outer shield DCR | 3.8 Ohm/1000ft (12 Ohm/km) |
| Nom. capacitance cond-to-shield | 16.2 pF/ft (53.1 pF/m) |
| Nom. velocity of prop. | 82% |
Return Loss
| Return loss 5 - 1600 MHz | 23 dB |
|---|---|
| Return loss 1600 - 4500 MHz | 21 dB |
| Return loss 4500 - 6000 MHz | 15 dB |
Attenuation (Nominal)
| Attenuation (nominal) 1 MHz | 0.24 dB/100ft |
|---|---|
| Attenuation (nominal) 3.58 MHz | 0.44 dB/100ft |
| Attenuation (nominal) 5 MHz | 0.52 dB/100ft |
| Attenuation (nominal) 6 MHz | 0.57 dB/100ft |
| Attenuation (nominal) 7 MHz | 0.61 dB/100ft |
| Attenuation (nominal) 10 MHz | 0.71 dB/100ft |
| Attenuation (nominal) 12 MHz | 0.78 dB/100ft |
| Attenuation (nominal) 25 MHz | 1.08 dB/100ft |
| Attenuation (nominal) 67.5 MHz | 1.65 dB/100ft |
| Attenuation (nominal) 71.5 MHz | 1.69 dB/100ft |
| Attenuation (nominal) 88.5 MHz | 1.86 dB/100ft |
| Attenuation (nominal) 100 MHz | 1.95 dB/100ft |
| Attenuation (nominal) 135 MHz | 2.24 dB/100ft |
| Attenuation (nominal) 143 MHz | 2.3 dB/100ft |
| Attenuation (nominal) 180 MHz | 2.57 dB/100ft |
| Attenuation (nominal) 270 MHz | 3.17 dB/100ft |
| Attenuation (nominal) 360 MHz | 3.69 dB/100ft |
| Attenuation (nominal) 540 MHz | 4.5 dB/100ft |
| Attenuation (nominal) 720 MHz | 5.3 dB/100ft |
| Attenuation (nominal) 750 MHz | 5.4 dB/100ft |
| Attenuation (nominal) 1000 MHz | 6.3 dB/100ft |
| Attenuation (nominal) 1500 MHz | 7.8 dB/100ft |
| Attenuation (nominal) 2000 MHz | 9.2 dB/100ft |
| Attenuation (nominal) 2250 MHz | 9.8 dB/100ft |
| Attenuation (nominal) 3000 MHz | 11.5 dB/100ft |
| Attenuation (nominal) 4500 MHz | 14.5 dB/100ft |
| Attenuation (nominal) 6000 MHz | 17.7 dB/100ft |
Environmental & Mechanical Ratings
| UL temperature | 60°C |
|---|---|
| Operating temperature | -30°C to +75°C |
| Installation min. bend radius | 2.75 in (69.9 mm) |
| Max. pull tension | 69 lbs (31 kg) |
| Fire rating | Riser |
| Flammability / reaction to fire | UL1666 Vertical Shaft |
| Environmental suitability | Indoor/Outdoor, Indoor, UV Resistance, Aerial - Black only, When supported by messenger Wire |
Compliance & Certifications
| NEC / UL compliance | CMR |
|---|---|
| CEC / C(UL) compliance | CMG |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
Belden 1694A 007 Applications
- Use it for digital video signal transmission.
- Support 6 Gb/s UHDTV distribution where consistent digital video performance is required.
- Deploy it for HD-SDI 1080p video links in professional video systems.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Coax construction | Coaxial |
| Coax Type | RG-6 |
| RG type | 6 |
| Overall cable diameter (nominal) | 0.274 in (6.96 mm) |
| Conductor nom. diameter | 0.040 in |
| Nom. insulation diameter | 0.180 in (4.57 mm) |
| Shield Type | Both, braid over foil |
| Flooded | No not flooded over braid |
| Jacket nom. diameter | 0.274 in (6.96 mm) |
| Outdoor | No not outdoor grade material |
| Bulk cable weight | 41 lbs/1000ft (61 kg/km) |
| Plenum number | 1695A |
| Nom. conductor DCR | 6.4 Ohm/1000ft (21 Ohm/km) |
| Nom. outer shield DCR | 3.8 Ohm/1000ft (12 Ohm/km) |
| Nom. capacitance (Cond-to-Shield) | 16.2 pF/ft (53.1 pF/m) |
| Nom. velocity of prop. | 82% |
| Return loss (5 - 1600 MHz) | 23 dB |
| Return loss (1600 - 4500 MHz) | 21 dB |
| Return loss (4500 - 6000 MHz) | 15 dB |
| Attenuation (nominal) 1 MHz | 0.24 dB/100ft |
| Attenuation (Nominal) 3.58 MHz | 0.44 dB/100ft |
| Attenuation (Nominal) 5 MHz | 0.52 dB/100ft |
| Attenuation (Nominal) 6 MHz | 0.57 dB/100ft |
| Attenuation (Nominal) 7 MHz | 0.61 dB/100ft |
| Attenuation (nominal) 10 MHz | 0.71 dB/100ft |
| Attenuation (Nominal) 12 MHz | 0.78 dB/100ft |
| Attenuation (Nominal) 25 MHz | 1.08 dB/100ft |
| Attenuation (Nominal) 67.5 MHz | 1.65 dB/100ft |
| Attenuation (Nominal) 71.5 MHz | 1.69 dB/100ft |
| Attenuation (Nominal) 88.5 MHz | 1.86 dB/100ft |
| Attenuation (nominal) 100 MHz | 1.95 dB/100ft |
| Attenuation (Nominal) 135 MHz | 2.24 dB/100ft |
| Attenuation (Nominal) 143 MHz | 2.3 dB/100ft |
| Attenuation (Nominal) 180 MHz | 2.57 dB/100ft |
| Attenuation (Nominal) 270 MHz | 3.17 dB/100ft |
| Attenuation (Nominal) 360 MHz | 3.69 dB/100ft |
| Attenuation (Nominal) 540 MHz | 4.5 dB/100ft |
| Attenuation (Nominal) 720 MHz | 5.3 dB/100ft |
| Attenuation (Nominal) 750 MHz | 5.4 dB/100ft |
| Attenuation (nominal) 1000 MHz | 6.3 dB/100ft |
| Attenuation (Nominal) 1500 MHz | 7.8 dB/100ft |
| Attenuation (Nominal) 2000 MHz | 9.2 dB/100ft |
| Attenuation (Nominal) 2250 MHz | 9.8 dB/100ft |
| Attenuation (Nominal) @ 3000 MHz | 11.5 dB/100ft |
| Attenuation (Nominal) 4500 MHz | 14.5 dB/100ft |
| Attenuation (Nominal) 6000 MHz | 17.7 dB/100ft |
| UL temperature | 60°C |
| Operating temperature | -30°C to +75°C |
| Installation min. bend radius | 2.75 in (69.9 mm) |
| Max Pull Tension | 69 lbs (31 kg) |
| Fire rating | Riser |
| Flammability / reaction to fire | UL1666 Vertical Shaft |
| Environmental suitability | Indoor/Outdoor, Indoor, UV Resistance, Aerial - Black only, When supported by messenger Wire |
| NEC / UL compliance | CMR |
| CEC / C(UL) compliance | CMG |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.