Belden 1695A 007, Low Loss Serial Digital Coax 18 AWG FFEP

SKU:Belden 1695A 007
● Auf Lager
Beschreibung
Belden 1695A 007 is a 75 Ohm SDI coax (RG type: 6) designed for low-loss digital video performance in Plenum spaces. It uses an 18 AWG solid BC - Bare Copper conductor with FEP - Fluorinated Ethylene Propylene (Foam) insulation and a PVC - Polyvinyl Chloride jacket in Violet. Shielding combines Duofoil® tape (100%) with a 95% Tinned Copper (TC) braid, and the cable is rated 300 V (CMP).
Belden 1695A 007 Key Features
- 75 Ohm characteristic impedance for SDI coax applications.
- RG type: 6 coaxial construction with an 18 AWG solid BC - Bare Copper conductor.
- Dual-layer shielding with Tape, Tri-Laminate (Alum+Poly+Alum), Duofoil®, 100% plus Braid, Tinned Copper (TC), 95%.
- PVC - Polyvinyl Chloride jacket with CMP rating and Violet jacket color for identification.
- Designed for low-loss digital video performance in Plenum spaces, including 6 Gb/s UHDTV and HD-SDI 1080p.
Belden 1695A 007 Technical Specs
Physical Construction
| Overall Cable Diameter (nominal) | 0.229 in (5.82 mm) |
|---|---|
| Conductor Diameter (nominal) | 0.040 in |
| Insulation Material | FEP - Fluorinated Ethylene Propylene (Foam) |
| Insulation Diameter (nominal) | 0.170 in (4.32 mm) |
| Insulation Color code | White |
| Bulk Cable Weight | 41 lbs/1000ft |
| Non-Plenum number | 1694A |
Electrical Characteristics
| Nom. Conductor DCR | 6.4 Ohm/1000ft |
|---|---|
| Nom. outer Shield DCR | 2.8 Ohm/1000ft (9.2 Ohm/km) |
| Nom. capacitance Cond-to-Shield | 16.2 pF/ft (53.1 pF/m) |
| Nom. velocity of prop. | 83% |
Return Loss
| Return loss 5 - 1600 MHz | 23 dB |
|---|---|
| Return loss 1600 - 4500 MHz | 21 dB |
| Return loss 4500 - 6000 MHz | 15 dB |
Attenuation (Nom.)
| Attenuation (Nom.) 1 MHz | 0.24 dB/100ft |
|---|---|
| Attenuation (Nom.) 3.58 MHz | 0.45 dB/100ft |
| Attenuation (Nom.) 5 MHz | 0.55 dB/100ft |
| Attenuation (Nom.) 7 MHz | 0.65 dB/100ft |
| Attenuation (Nom.) 10 MHz | 0.75 dB/100ft |
| Attenuation (Nom.) 67.5 MHz | 1.74 dB/100ft |
| Attenuation (Nom.) 71.5 MHz | 1.78 dB/100ft |
| Attenuation (Nom.) 88.5 MHz | 1.94 dB/100ft |
| Attenuation (Nom.) 100 MHz | 2.1 dB/100ft |
| Attenuation (Nom.) 135 MHz | 2.4 dB/100ft |
| Attenuation (Nom.) 143 MHz | 2.5 dB/100ft |
| Attenuation (Nom.) 180 MHz | 2.8 dB/100ft |
| Attenuation (Nom.) 270 MHz | 3.4 dB/100ft |
| Attenuation (Nom.) 360 MHz | 4.0 dB/100ft |
| Attenuation (Nom.) 540 MHz | 5.2 dB/100ft |
| Attenuation (Nom.) 720 MHz | 6.1 dB/100ft |
| Attenuation (Nom.) 750 MHz | 6.2 dB/100ft |
| Attenuation (Nom.) 1000 MHz | 7.4 dB/100ft |
| Attenuation (Nom.) 1500 MHz | 9.5 dB/100ft |
| Attenuation (Nom.) 2000 MHz | 11.3 dB/100ft |
| Attenuation (Nom.) 2250 MHz | 12.2 dB/100ft |
| Attenuation (Nom.) 3000 MHz | 14.6 dB/100ft |
| Attenuation (Nom.) 4500 MHz | 18.6 dB/100ft |
| Attenuation (Nom.) 6000 MHz | 22.4 dB/100ft |
Environmental & Mechanical Ratings
| UL temperature | 75°C |
|---|---|
| Operating | 0°C to +75°C |
| Installation min. Bend Radius | 2.3 in (58 mm) |
| Max. pull tension | 92 lbs (42 kg) |
| Environmental suitability | Indoor - Plenum, Indoor |
Compliance & Certifications
| NEC / UL compliance | CMP |
|---|---|
| CEC / C(UL) compliance | CMP |
| Flammability / reaction to fire | NFPA 262 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
Belden 1695A 007 Applications
- Supports digital video signal distribution where consistent performance is required.
- Enables 6 Gb/s UHDTV signal paths in professional video systems.
- Provides HD-SDI 1080p connectivity in broadcast and AV installations.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Overall cable diameter (nominal) | 0.229 in (5.82 mm) |
| Conductor diameter (nominal) | 0.040 in |
| Insulation Material | FEP - Fluorinated Ethylene Propylene (Foam) |
| Insulation diameter (nominal) | 0.170 in (4.32 mm) |
| Insulation color code | White |
| Bulk cable weight | 41 lbs/1000ft |
| Non-Plenum number | 1694A |
| Nom. conductor DCR | 6.4 Ohm/1000ft |
| Nom. outer shield DCR | 2.8 Ohm/1000ft (9.2 Ohm/km) |
| Nom. capacitance (Cond-to-Shield) | 16.2 pF/ft (53.1 pF/m) |
| Nom. velocity of prop. | 83% |
| Return loss (5 - 1600 MHz) | 23 dB |
| Return loss (1600 - 4500 MHz) | 21 dB |
| Return loss (4500 - 6000 MHz) | 15 dB |
| Attenuation (Nom.) 1 MHz | 0.24 dB/100ft |
| Attenuation (Nom.) 3.58 MHz | 0.45 dB/100ft |
| Attenuation (Nom.) 5 MHz | 0.55 dB/100ft |
| Attenuation (Nom.) 7 MHz | 0.65 dB/100ft |
| Attenuation (Nom.) 10 MHz | 0.75 dB/100ft |
| Attenuation (Nom.) 67.5 MHz | 1.74 dB/100ft |
| Attenuation (Nom.) 71.5 MHz | 1.78 dB/100ft |
| Attenuation (Nom.) 88.5 MHz | 1.94 dB/100ft |
| Attenuation (Nom.) 100 MHz | 2.1 dB/100ft |
| Attenuation (Nom.) 135 MHz | 2.4 dB/100ft |
| Attenuation (Nom.) 143 MHz | 2.5 dB/100ft |
| Attenuation (Nom.) 180 MHz | 2.8 dB/100ft |
| Attenuation (Nom.) 270 MHz | 3.4 dB/100ft |
| Attenuation (Nom.) 360 MHz | 4.0 dB/100ft |
| Attenuation (Nom.) 540 MHz | 5.2 dB/100ft |
| Attenuation (Nom.) 720 MHz | 6.1 dB/100ft |
| Attenuation (Nom.) 750 MHz | 6.2 dB/100ft |
| Attenuation (Nom.) 1000 MHz | 7.4 dB/100ft |
| Attenuation (Nom.) 1500 MHz | 9.5 dB/100ft |
| Attenuation (Nom.) 2000 MHz | 11.3 dB/100ft |
| Attenuation (Nom.) 2250 MHz | 12.2 dB/100ft |
| Attenuation (Nom.) 3000 MHz | 14.6 dB/100ft |
| Attenuation (Nom.) 4500 MHz | 18.6 dB/100ft |
| Attenuation (Nom.) 6000 MHz | 22.4 dB/100ft |
| UL temperature | 75°C |
| Operating | 0°C to +75°C |
| Installation min. bend radius | 2.3 in (58 mm) |
| Max Pull Tension | 92 lbs (42 kg) |
| Environmental suitability | Indoor - Plenum, Indoor |
| NEC / UL compliance | CMP |
| CEC / C(UL) compliance | CMP |
| Flammability / reaction to fire | NFPA 262 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.