Belden 1855A 004, Coax Sub Miniature 23 AWG PE PVC Yellow

SKU:Belden 1855A 004
● Auf Lager
Beschreibung
Belden 1855A 004 is a 75 Ohm SDI coax designed for high-performance digital video, including 6 Gb/s UHDTV and HD-SDI 1080p. This Mini RG-59 style cable uses a 23 AWG solid BC - Bare Copper conductor with PE - Polyethylene (Foam) insulation and a PVC - Polyvinyl Chloride jacket. Shielding is built with Duofoil® tri-laminate tape plus a 95% Tinned Copper braid. The cable is rated CMR with a 300 V (CMR, CMG) UL Voltage Rating.
Belden 1855A 004 Key Features
- 75 Ohm coax optimized for SDI digital video performance, including 6 Gb/s UHDTV and HD-SDI 1080p.
- 23 AWG solid BC - Bare Copper conductor with PE - Polyethylene (Foam) insulation for consistent signal integrity.
- Duofoil® tri-laminate tape shield plus a 95% Tinned Copper braid for braid-over-foil shielding.
- PVC - Polyvinyl Chloride jacket with CMR rating and 300 V (CMR, CMG) UL Voltage Rating.
Belden 1855A 004 Technical Specs
Construction & Physical Specs
| Coax construction | Coaxial |
|---|---|
| RG type | Mini 59 |
| Coax type | RG 59 |
| Overall cable diameter (nominal) | 0.159 in (4.04 mm) |
| Jacket color | Yellow |
| Nom. diameter (conductor) | 0.023 in |
| Nom. insulation diameter | 0.102 in (2.59 mm) |
| Color code | White |
| Shield type | Both, braid over foil |
| Shield layer 1 | Tape; Tri-Laminate (Alum+Poly+Alum); Duofoil®; 100% |
| Shield layer 2 | Braid; Tinned Copper (TC); 95% |
| Flooded | No not flooded over braid |
Performance & Electrical Characteristics
| Nom. capacitance cond-to-shield | 16.3 pF/ft (53.5 pF/m) |
|---|---|
| Nom. velocity of prop. | 82% |
| Nom. conductor DCR | 20.1 Ohm/1000ft (65.9 Ohm/km) |
| Nom. outer shield DCR | 3.7 Ohm/1000ft (12 Ohm/km) |
| Return loss (5 - 1600 MHz) | 23 dB |
| Return loss (1600 - 4500 MHz) | 21 dB |
| Return loss (4500 - 6000 MHz) | 15 dB |
| Attenuation (nominal) 1 MHz | 0.39 dB/100ft |
| Attenuation (nominal) 3.58 MHz | 0.78 dB/100ft |
| Attenuation (nominal) 5 MHz | 0.92 dB/100ft |
| Attenuation (nominal) 6 MHz | 1.00 dB/100ft |
| Attenuation (nominal) 7 MHz | 1.08 dB/100ft |
| Attenuation (nominal) 10 MHz | 1.2 dB/100ft |
| Attenuation (nominal) 12 MHz | 1.3 dB/100ft |
| Attenuation (nominal) 25 MHz | 1.8 dB/100ft |
| Attenuation (nominal) 67.5 MHz | 2.83 dB/100ft |
| Attenuation (nominal) 71.5 MHz | 2.93 dB/100ft |
| Attenuation (nominal) 88.5 MHz | 3.22 dB/100ft |
| Attenuation (nominal) 100 MHz | 3.39 dB/100ft |
| Attenuation (nominal) 135 MHz | 3.84 dB/100ft |
| Attenuation (nominal) 143 MHz | 4.00 dB/100ft |
| Attenuation (nominal) 180 MHz | 4.41 dB/100ft |
| Attenuation (nominal) 270 MHz | 5.44 dB/100ft |
| Attenuation (nominal) 360 MHz | 6.34 dB/100ft |
| Attenuation (nominal) 540 MHz | 7.85 dB/100ft |
| Attenuation (nominal) 720 MHz | 9.15 dB/100ft |
| Attenuation (nominal) 750 MHz | 9.31 dB/100ft |
| Attenuation (nominal) 1000 MHz | 10.89 dB/100ft |
| Attenuation (nominal) 1500 MHz | 13.38 dB/100ft |
| Attenuation (nominal) 2000 MHz | 15.64 dB/100ft |
| Attenuation (nominal) 2250 MHz | 16.68 dB/100ft |
| Attenuation (nominal) 3000 MHz | 19.65 dB/100ft |
| Attenuation (nominal) 4500 MHz | 24.35 dB/100ft |
| Attenuation (nominal) 6000 MHz | 28.97 dB/100ft |
Environmental & Mechanical Ratings
| UL temperature | 75°C |
|---|---|
| Operating | -30°C to +75°C |
| Installation min. bend radius | 1.6 in (41 mm) |
| Max. pull tension | 33 lbs (15 kg) |
| Bulk cable weight | 17 lbs/1000ft (25 kg/km) |
| Environmental suitability | Indoor/Outdoor, Indoor, UV Resistance, Aerial - Black only, When supported by messenger Wire |
| Outdoor | No not outdoor grade material |
Compliance & Certifications
| NEC / UL compliance | CMR |
|---|---|
| CEC / C(UL) compliance | CMG |
| Flammability / reaction to fire | UL1666 Vertical Shaft |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
| Plenum number | 1855P |
Belden 1855A 004 Applications
- Use it in digital video signal paths that require a 75 Ohm SDI coax.
- Support 6 Gb/s UHDTV video distribution in professional AV and broadcast signal chains.
- Choose it for HD-SDI 1080p installations that need consistent SDI performance.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Coax construction | Coaxial |
| RG type | Mini 59 |
| Coax Type | RG 59 |
| Overall cable diameter (nominal) | 0.159 in (4.04 mm) |
| Jacket Color | Yellow |
| Nom. Diameter (conductor) | 0.023 in |
| Nom. insulation diameter | 0.102 in (2.59 mm) |
| Color Code | White |
| Shield Type | Both, braid over foil |
| Shield layer 1 | Tape; Tri-Laminate (Alum+Poly+Alum); Duofoil®; 100% |
| Shield layer 2 | Braid; Tinned Copper (TC); 95% |
| Flooded | No not flooded over braid |
| Nom. capacitance (Cond-to-Shield) | 16.3 pF/ft (53.5 pF/m) |
| Nom. velocity of prop. | 82% |
| Nom. conductor DCR | 20.1 Ohm/1000ft (65.9 Ohm/km) |
| Nom. outer shield DCR | 3.7 Ohm/1000ft (12 Ohm/km) |
| Return loss (5 - 1600 MHz) | 23 dB |
| Return loss (1600 - 4500 MHz) | 21 dB |
| Return loss (4500 - 6000 MHz) | 15 dB |
| Attenuation (nominal) 1 MHz | 0.39 dB/100ft |
| Attenuation (Nominal) 3.58 MHz | 0.78 dB/100ft |
| Attenuation (Nominal) 5 MHz | 0.92 dB/100ft |
| Attenuation (Nominal) 6 MHz | 1.00 dB/100ft |
| Attenuation (Nominal) 7 MHz | 1.08 dB/100ft |
| Attenuation (nominal) 10 MHz | 1.2 dB/100ft |
| Attenuation (Nominal) 12 MHz | 1.3 dB/100ft |
| Attenuation (Nominal) 25 MHz | 1.8 dB/100ft |
| Attenuation (Nominal) 67.5 MHz | 2.83 dB/100ft |
| Attenuation (Nominal) 71.5 MHz | 2.93 dB/100ft |
| Attenuation (Nominal) 88.5 MHz | 3.22 dB/100ft |
| Attenuation (nominal) 100 MHz | 3.39 dB/100ft |
| Attenuation (Nominal) 135 MHz | 3.84 dB/100ft |
| Attenuation (Nominal) 143 MHz | 4.00 dB/100ft |
| Attenuation (Nominal) 180 MHz | 4.41 dB/100ft |
| Attenuation (Nominal) 270 MHz | 5.44 dB/100ft |
| Attenuation (Nominal) 360 MHz | 6.34 dB/100ft |
| Attenuation (Nominal) 540 MHz | 7.85 dB/100ft |
| Attenuation (Nominal) 720 MHz | 9.15 dB/100ft |
| Attenuation (Nominal) 750 MHz | 9.31 dB/100ft |
| Attenuation (nominal) 1000 MHz | 10.89 dB/100ft |
| Attenuation (Nominal) 1500 MHz | 13.38 dB/100ft |
| Attenuation (Nominal) 2000 MHz | 15.64 dB/100ft |
| Attenuation (Nominal) 2250 MHz | 16.68 dB/100ft |
| Attenuation (Nominal) @ 3000 MHz | 19.65 dB/100ft |
| Attenuation (Nominal) 4500 MHz | 24.35 dB/100ft |
| Attenuation (Nominal) 6000 MHz | 28.97 dB/100ft |
| UL temperature | 75°C |
| Operating | -30°C to +75°C |
| Installation min. bend radius | 1.6 in (41 mm) |
| Max Pull Tension | 33 lbs (15 kg) |
| Bulk cable weight | 17 lbs/1000ft (25 kg/km) |
| Environmental suitability | Indoor/Outdoor, Indoor, UV Resistance, Aerial - Black only, When supported by messenger Wire |
| Outdoor | No not outdoor grade material |
| NEC / UL compliance | CMR |
| CEC / C(UL) compliance | CMG |
| Flammability / reaction to fire | UL1666 Vertical Shaft |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
| Plenum number | 1855P |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.