Belden 2183P D15A is a 4K UHD media cable for HDBaseT and Full 5-Play installations, supporting 4K (UHD/DCI) along with POH and POE. It features 4 pair 23 AWG solid bare copper conductors with FEP insulation in an F/UTP design. Designed for plenum pathways, it uses a Blue Flamarrest® jacket and meets CMP-LP (0.6A) requirements.
Belden 2183P D15A Key Features
- Supports HDBaseT and Full 5-Play installations, including 4K (UHD/DCI), POH, and POE.
- Built with 4 pair 23 AWG solid bare copper conductors and FEP - Fluorinated Ethylene Propylene insulation.
- F/UTP construction with a tape outer shield using Bi-Laminate (Alum+Poly) and 100% shield coverage.
- Includes 26 AWG (Solid) TC drainwire type, with two drain wires applied helically for flexibility.
- Designed for plenum pathways with a Blue Flamarrest® jacket and CMP-LP (0.6A) rating.
Belden 2183P D15A Technical Specs
Construction & Physical Specs
| Color code | Western Electric (Modified) |
|---|---|
| Insulation nominal thickness | 0.010 in (0.25 mm) |
| Ripcord | Yes |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Outer jacket nominal thickness | 0.018 in (0.46 mm) |
| Overall cable diameter (nominal) | 0.270 in |
| Outer jacket nominal diameter | 0.270 in |
| Bulk cable weight | 36 lbs/1000ft |
| Non-Plenum number | 2183R |
Electrical Characteristics
| UL voltage rating | 300 V |
|---|---|
| Nominal conductor DCR | 22.7 Ohm/1000ft |
| Nom outer shield DCR | 5.87 Ohm/1000ft (19.3 Ohm/km) |
| Max. capacitance unbalance | 330 pF/100m |
| Nom. velocity of prop. | 72% |
| Max. current | 3.1 Amps per Conductor at 25ºC |
High Frequency (nominal/typical) Attenuation
| High frequency (nominal/typical) 1 MHz | 2 dB/100m |
|---|---|
| High frequency (nominal/typical) 4 MHz | 3.8 dB/100m |
| High frequency (nominal/typical) 8 MHz | 4.3 dB/100m |
| High frequency (nominal/typical) 10 MHz | 5.9 dB/100m |
| High frequency (nominal/typical) 16 MHz | 7.5 dB/100m |
| High frequency (nominal/typical) 20 MHz | 8.3 dB/100m |
| High frequency (nominal/typical) 25 MHz | 9.3 dB/100m |
| High frequency (nominal/typical) 31.2 MHz | 10.4 dB/100m |
| High frequency (nominal/typical) 62.5 MHz | 14.8 dB/100m |
| High frequency (nominal/typical) 100 MHz | 18.8 dB/100m |
| High frequency (nominal/typical) 125 MHz | 21 dB/100m |
| High frequency (nominal/typical) 155 MHz | 23 dB/100m |
| High frequency (nominal/typical) 175 MHz | 24.9 dB/100m |
Environmental & Mechanical Ratings
| UL temperature | 90°C |
|---|---|
| Operating temperature | -20°C to +90°C |
| Installation temperature | 0°C To +75°C |
| Storage temperature | -20°C to +75°C |
| Bend radius (stationary min.) | 2.7 in (69 mm) |
| Bend radius (installation min.) | 2.7 in |
| Max. pull tension | 45 lbs (20 kg) |
| Environmental suitability | Indoor - Plenum, Indoor, Outdoor |
| Flammability / reaction to fire | NFPA 262 (UL 910), FT6 |
Compliance & Certifications
| CPR compliance | CPR Euroclass: Eca |
|---|---|
| NEC / UL compliance | Article 800, CMP-LP (0.6A), CL3P |
| CEC / C(UL) compliance | CMP |
| IEEE compliance | POE per 802.3af & POE+ 802.3at-2009 |
| ISO/IEC compliance | 11801 ed 2.2 (2011) Class D |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2017-07-10 |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Belden 2183P D15A Applications
- Use in HDBaseT installations where 4K (UHD/DCI) signal delivery is required.
- Deploy for Full 5-Play installations that combine multiple services over a single installation.
- Integrate into systems that use POH and POE to deliver power alongside data.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Color Code | Western Electric (Modified) |
| Insulation nominal thickness | 0.010 in (0.25 mm) |
| Ripcord | Yes |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Outer jacket nominal thickness | 0.018 in (0.46 mm) |
| Overall cable diameter (nominal) | 0.270 in |
| Outer jacket nominal diameter | 0.270 in |
| Bulk cable weight | 36 lbs/1000ft |
| Non-Plenum number | 2183R |
| UL Voltage Rating | 300 V |
| Nominal conductor DCR | 22.7 Ohm/1000ft |
| Nom. outer shield DCR | 5.87 Ohm/1000ft (19.3 Ohm/km) |
| Max. capacitance unbalance | 330 pF/100m |
| Nom. velocity of prop. | 72% |
| Max. current | 3.1 Amps per Conductor at 25ºC |
| High frequency (nominal/typical) 1 MHz | 2 dB/100m |
| High frequency (nominal/typical) 4 MHz | 3.8 dB/100m |
| High frequency (nominal/typical) 8 MHz | 4.3 dB/100m |
| High frequency (nominal/typical) 10 MHz | 5.9 dB/100m |
| High frequency (nominal/typical) 16 MHz | 7.5 dB/100m |
| High frequency (nominal/typical) 20 MHz | 8.3 dB/100m |
| High frequency (nominal/typical) 25 MHz | 9.3 dB/100m |
| High frequency (nominal/typical) 31.2 MHz | 10.4 dB/100m |
| High frequency (nominal/typical) 62.5 MHz | 14.8 dB/100m |
| High frequency (nominal/typical) 100 MHz | 18.8 dB/100m |
| High frequency (nominal/typical) 125 MHz | 21 dB/100m |
| High frequency (nominal/typical) 155 MHz | 23 dB/100m |
| High frequency (nominal/typical) 175 MHz | 24.9 dB/100m |
| UL temperature | 90°C |
| Operating temperature | -20°C to +90°C |
| Installation temperature | 0°C To +75°C |
| Storage temperature | -20°C to +75°C |
| Bend radius (stationary min.) | 2.7 in (69 mm) |
| Bend radius (installation min.) | 2.7 in |
| Max Pull Tension | 45 lbs (20 kg) |
| Environmental suitability | Indoor - Plenum, Indoor, Outdoor |
| Flammability / reaction to fire | NFPA 262 (UL 910), FT6 |
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 800, CMP-LP (0.6A), CL3P |
| CEC / C(UL) compliance | CMP |
| IEEE compliance | POE per 802.3af & POE+ 802.3at-2009 |
| ISO/IEC compliance | 11801 ed 2.2 (2011) Class D |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2017-07-10 |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.