Belden 27325AS, Multi Conductor Type TC Cable 2C 18 AWG 600V PVC

SKU:Belden 27325AS
● Auf Lager
Beschreibung
Belden 27325AS is a UL Type TC (1277) multi conductor control cable for power and control applications up to 600V, including Class 1 Division 2 hazardous locations. It features 2 stranded 18 AWG (7x26) BC - Bare Copper conductors with PVC-Nylon/PVC insulation and an overall Beldfoil® shield for noise protection. The cable has a black PVC outer jacket with ripcord and is rated 90°C dry and 90°C wet for wet/dry environments. It is listed for indoor/outdoor use with sunlight resistance and burial capability, with a recommended cable gland of Belden BTC075A0551RA.
Belden 27325AS Key Features
- UL Type TC (1277) multi conductor control cable for power and control applications up to 600V, including Class 1 Division 2 hazardous locations.
- 2 stranded 18 AWG (7x26) BC - Bare Copper conductors.
- Overall Beldfoil® shield (tape) with 100% coverage for noise protection.
- Black PVC outer jacket with ripcord for easier installation.
- UL temperature rating of 90°C dry and 90°C wet for wet/dry environments.
- Environmental suitability: indoor, outdoor, sunlight resistance, burial.
- Recommended cable gland: Belden BTC075A0551RA.
Belden 27325AS Technical Specs
Construction & Materials
| Conductor count | 2 |
|---|---|
| Conductor size | 18 AWG |
| Stranding | 7x26 |
| Conductor material | BC - Bare Copper |
| Insulation material | PVC/Nylon - Polyvinyl Chloride + Nylon |
| Color code | Black, Red |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Coverage | 100% |
| Drainwire type | 20 AWG (7x28) TC |
| Jacket material | PVC - Polyvinyl Chloride |
| Ripcord | Yes |
Dimensions & Weight
| Nom. thickness | 0.022 in (0.56 mm) |
|---|---|
| Nom. insulation diameter | 0.088 in (2.2 mm) |
| Nom. jacket thickness | 0.048 in (1.2 mm) |
| Overall cable diameter (nominal) | 0.276 in (7.01 mm) |
| Bulk cable weight | 33 lbs/1000ft |
Electrical Characteristics
| UL voltage rating | 600 V (TC), 150 V (NPLF) |
|---|---|
| Nom. conductor DCR | 6.7 Ohm/1000ft |
| Nom outer shield DCR | 10.39 Ohm/1000ft (34.09 Ohm/km) |
| Max. current | 14 Amps per Conductor at 30ºC |
Environmental & Mechanical Ratings
| Operating | Wet/Dry: -30°C to 90°C |
|---|---|
| Bend radius (stationary min.) | 3.312 in (84.12 mm) |
| Bend radius (installation min.) | 3.312 in (84.12 mm) |
| Max. pull tension | 53 lbs (24 kg) |
Compliance & Certifications
| Flammability / reaction to fire | UL1685 UL Loading, IEEE 1202 FT4 |
|---|---|
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 336, Article 400, Article 760, NPLF, TC, TFFN |
| European directive compliance | EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
Belden 27325AS Applications
- Use it for power and control applications up to 600V.
- Specify it for Class 1 Division 2 hazardous locations.
- Pair it with the recommended cable gland Belden BTC075A0551RA.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Conductor count | 2 |
| Conductor size | 18 AWG |
| Stranding | 7x26 |
| Conductor Material | BC - Bare Copper |
| Insulation Material | PVC/Nylon - Polyvinyl Chloride + Nylon |
| Color Code | Black, Red |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Coverage | 100% |
| Drainwire type | 20 AWG (7x28) TC |
| Jacket Material | PVC - Polyvinyl Chloride |
| Ripcord | Yes |
| Nom. thickness | 0.022 in (0.56 mm) |
| Nom. insulation diameter | 0.088 in (2.2 mm) |
| Nom. jacket thickness | 0.048 in (1.2 mm) |
| Overall cable diameter (nominal) | 0.276 in (7.01 mm) |
| Bulk cable weight | 33 lbs/1000ft |
| UL Voltage Rating | 600 V (TC), 150 V (NPLF) |
| Nom. conductor DCR | 6.7 Ohm/1000ft |
| Nom. outer shield DCR | 10.39 Ohm/1000ft (34.09 Ohm/km) |
| Max. current | 14 Amps per Conductor at 30ºC |
| Operating | Wet/Dry: -30°C to 90°C |
| Bend radius (stationary min.) | 3.312 in (84.12 mm) |
| Bend radius (installation min.) | 3.312 in (84.12 mm) |
| Max Pull Tension | 53 lbs (24 kg) |
| Flammability / reaction to fire | UL1685 UL Loading, IEEE 1202 FT4 |
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 336, Article 400, Article 760, NPLF, TC, TFFN |
| European directive compliance | EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.