Belden 27337AS, Multi Conductor Type TC Cable 2C 16 AWG 600V PVC

SKU:Belden 27337AS
● Auf Lager
Beschreibung
Belden 27337AS is a UL Type TC (1277) multi conductor control cable for power and control applications up to 600 V (TC), with a 150 V (NPLF) rating. It is built with 2 stranded 16 AWG (7x24) BC - Bare Copper conductors, PVC/Nylon - Polyvinyl Chloride + Nylon insulation, and an overall Beldfoil® shield. A black PVC - Polyvinyl Chloride outer jacket includes a ripcord and is marked SUN RES DIR BUR for indoor/outdoor use. The cable is rated 90°C Dry, 90°C Wet and is suitable for Class 1 Division 2 hazardous locations.
Belden 27337AS Key Features
- UL Type TC (1277) multi conductor control cable for power and control applications up to 600 V (TC).
- 2 stranded 16 AWG (7x24) BC - Bare Copper conductors for control and power wiring.
- PVC/Nylon - Polyvinyl Chloride + Nylon insulation with color code: Black, Red.
- Overall Beldfoil® shield (tape) with 100% coverage and drainwire type: 18 AWG (7x26) TC.
- Black PVC - Polyvinyl Chloride outer jacket with ripcord: Yes for easier stripping.
- UL temperature: 90°C Dry, 90°C Wet; additional markings include 600V TC 150V NPLF 90C Wet/Dry SUN RES DIR BUR.
Belden 27337AS Technical Specs
Construction & Materials
| Number of conductors | 2 |
|---|---|
| Conductor size | 16 AWG |
| Stranding | 7x24 |
| Conductor material | BC - Bare Copper |
| Insulation material | PVC/Nylon - Polyvinyl Chloride + Nylon |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Coverage | 100% |
| Drainwire type | 18 AWG (7x26) TC |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Jacket color | Black |
| Ripcord | Yes |
| Armor | No |
| Composite | No |
| Earth/ground wires | No |
Dimensions & Weight
| Nom. thickness | 0.022 in (0.56 mm) |
|---|---|
| Nom. insulation diameter | 0.101 in (2.57 mm) |
| Nom. jacket thickness | 0.047 in (1.2 mm) |
| Nom. diameter | 0.302 in (7.67 mm) |
| Bulk cable weight | 53 lbs/1000ft |
Electrical Characteristics
| UL voltage rating | 600 V (TC), 150 V (NPLF) |
|---|---|
| Nom. conductor DCR | 4.2 Ohm/1000ft |
| Max. current | 18 Amps per Conductor at 30ºC |
| Nom outer shield DCR | 4.83 Ohm/1000ft (15.8 Ohm/km) |
Environmental & Mechanical Ratings
| Operating | Wet/Dry: -30°C to 90°C |
|---|---|
| Bend radius (stationary min.) | 3.624 in (92.05 mm) |
| Bend radius (installation min.) | 3.624 in (92.05 mm) |
| Max. pull tension | 90 lbs (41 kg) |
| Environmental suitability | Indoor, Outdoor, Sunlight Resistance |
| Flammability / reaction to fire | UL1685 UL Loading, IEEE 1202 FT4 |
Compliance & Certifications
| NEC / UL compliance | Article 336, Article 400, Article 760, NPLF, TC, TFFN |
|---|---|
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| Additional markings | 600V TC 150V NPLF 90C Wet/Dry SUN RES DIR BUR |
Belden 27337AS Applications
- Use for power and control applications up to 600V where a UL Type TC (1277) cable is required.
- Install in Class 1 Division 2 hazardous locations.
- Select the recommended cable gland: Belden BTC075A0551RA.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Number of Conductors | 2 |
| Conductor size | 16 AWG |
| Stranding | 7x24 |
| Conductor Material | BC - Bare Copper |
| Insulation Material | PVC/Nylon - Polyvinyl Chloride + Nylon |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Coverage | 100% |
| Drainwire type | 18 AWG (7x26) TC |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Jacket Color | Black |
| Ripcord | Yes |
| Armor | No |
| Composite | No |
| Earth/ground wires | No |
| Nom. thickness | 0.022 in (0.56 mm) |
| Nom. insulation diameter | 0.101 in (2.57 mm) |
| Nom. jacket thickness | 0.047 in (1.2 mm) |
| Nom. diameter | 0.302 in (7.67 mm) |
| Bulk cable weight | 53 lbs/1000ft |
| UL Voltage Rating | 600 V (TC), 150 V (NPLF) |
| Nom. conductor DCR | 4.2 Ohm/1000ft |
| Max. current | 18 Amps per Conductor at 30ºC |
| Nom. outer shield DCR | 4.83 Ohm/1000ft (15.8 Ohm/km) |
| Operating | Wet/Dry: -30°C to 90°C |
| Bend radius (stationary min.) | 3.624 in (92.05 mm) |
| Bend radius (installation min.) | 3.624 in (92.05 mm) |
| Max Pull Tension | 90 lbs (41 kg) |
| Environmental suitability | Indoor, Outdoor, Sunlight Resistance |
| Flammability / reaction to fire | UL1685 UL Loading, IEEE 1202 FT4 |
| NEC / UL compliance | Article 336, Article 400, Article 760, NPLF, TC, TFFN |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| Additional markings | 600V TC 150V NPLF 90C Wet/Dry SUN RES DIR BUR |
| Priced Per | FT |