Belden 28081A, Power Limited Tray Cable 3C 14 AWG 600V PVC

SKU:Belden 28081A
● Auf Lager
Beschreibung
Belden 28081A is a power limited tray cable for power and control applications up to 600V, including Class 1 Division 2 hazardous locations. It is built with 3 stranded 14 AWG (7x22) BC - Bare Copper conductors and PVC/Nylon - Polyvinyl Chloride + Nylon insulation in an unshielded design. The cable features a black PVC - Polyvinyl Chloride outer jacket with ripcord and is rated UL Type TC (1277) and TC-ER. It is suitable for indoor/outdoor use with SUN RES and DIR BUR performance.
Belden 28081A Key Features
- Power limited tray cable for power and control applications up to 600V, including Class 1 Division 2 hazardous locations.
- 3 stranded 14 AWG (7x22) BC - Bare Copper conductors with PVC/Nylon - Polyvinyl Chloride + Nylon insulation.
- Unshielded construction supports straightforward terminations.
- Black PVC - Polyvinyl Chloride outer jacket with ripcord supports easier installation.
- UL Type TC (1277) and TC-ER ratings.
- Suitable for indoor/outdoor use with SUN RES and DIR BUR performance.
Belden 28081A Technical Specs
Construction & Materials
| Product type | VNTC Control |
|---|---|
| Number of conductors | 3 |
| Conductor size | 14 AWG |
| Stranding | 7x22 |
| Conductor material | BC - Bare Copper |
| Insulation material | PVC/Nylon - Polyvinyl Chloride + Nylon |
| Color code | Black, Red, Blue |
| Shield | No Shield |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Jacket color | Black |
| Ripcord | Yes |
| Armor | No |
| Composite | No |
| Earth/ground wires | No |
Dimensions & Weight
| Insulation nominal thickness | 0.024 in (0.61 mm) |
|---|---|
| Insulation nominal diameter | 0.116 in (2.95 mm) |
| Outer jacket nominal thickness | 0.047 in (1.2 mm) |
| Outer jacket nominal diameter | 0.335 in (8.51 mm) |
| Overall cable diameter (nominal) | 0.346 in (8.79 mm) |
| Bulk cable weight | 74 lbs/1000ft |
Electrical Characteristics
| UL voltage rating | 600 V (TC-ER), 150 V (NPLF) |
|---|---|
| Nom. conductor DCR | 2.67 Ohm/1000ft |
| Max. current | 24 Amps per Conductor at 30ºC |
Environmental & Mechanical Ratings
| UL temperature | 90°C Dry, 90°C Wet |
|---|---|
| Operating (wet/dry) | -30°C to 90°C |
| Bend radius (stationary min.) | 1.384 in (35.15 mm) |
| Bend radius (installation min.) | 1.73 in (43.9 mm) |
| Max. pull tension | 164 lbs (74.4 kg) |
| Flammability / reaction to fire | UL1685 UL Loading, IEEE 1202 FT4 |
Compliance & Certifications
| NEC / UL compliance | Article 336, NPLF, TC-ER, THWN-2 |
|---|---|
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Belden 28081A Applications
- Use it for power and control applications up to 600V.
- Specify it for Class 1 Division 2 hazardous locations.
- Select the recommended cable gland: Belden BTC075A0551RA.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Product type | VNTC Control |
| Number of Conductors | 3 |
| Conductor size | 14 AWG |
| Stranding | 7x22 |
| Conductor Material | BC - Bare Copper |
| Insulation Material | PVC/Nylon - Polyvinyl Chloride + Nylon |
| Color Code | Black, Red, Blue |
| Shield | No Shield |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Jacket Color | Black |
| Ripcord | Yes |
| Armor | No |
| Composite | No |
| Earth/ground wires | No |
| Insulation nominal thickness | 0.024 in (0.61 mm) |
| Insulation nominal diameter | 0.116 in (2.95 mm) |
| Outer jacket nominal thickness | 0.047 in (1.2 mm) |
| Outer jacket nominal diameter | 0.335 in (8.51 mm) |
| Overall cable diameter (nominal) | 0.346 in (8.79 mm) |
| Bulk cable weight | 74 lbs/1000ft |
| UL Voltage Rating | 600 V (TC-ER), 150 V (NPLF) |
| Nom. conductor DCR | 2.67 Ohm/1000ft |
| Max. current | 24 Amps per Conductor at 30ºC |
| UL temperature | 90°C Dry, 90°C Wet |
| Operating (wet/dry) | -30°C to 90°C |
| Bend radius (stationary min.) | 1.384 in (35.15 mm) |
| Bend radius (installation min.) | 1.73 in (43.9 mm) |
| Max Pull Tension | 164 lbs (74.4 kg) |
| Flammability / reaction to fire | UL1685 UL Loading, IEEE 1202 FT4 |
| NEC / UL compliance | Article 336, NPLF, TC-ER, THWN-2 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.