Belden 28110A, Control Cable 3C 12 AWG PVC NYL 600V UL TC ER E2

SKU:Belden 28110A
● Auf Lager
Beschreibung
Belden 28110A is a UL Type TC (1277) VNTC control cable with 3 conductor 12 AWG (7x20) BC - Bare Copper conductors and PVC/Nylon - Polyvinyl Chloride + Nylon insulation. It is rated 600 V (TC-ER) and 150 V (NPLF), with UL temperature ratings of 90°C dry and 90°C wet. This unshielded cable uses a black PVC - Polyvinyl Chloride outer jacket and includes a ripcord for easier jacket removal. It is listed for indoor, outdoor, sunlight resistance, and burial environments, including DIR BUR and SUN RES markings.
Belden 28110A Key Features
- UL Type TC (1277) VNTC control cable construction for power and control applications up to 600 V.
- 3 conductor 12 AWG (7x20) stranded BC - Bare Copper conductors with PVC/Nylon - Polyvinyl Chloride + Nylon insulation.
- Unshielded design with no ground wires.
- Black PVC - Polyvinyl Chloride outer jacket with a ripcord for easier jacket removal.
- UL voltage rating: 600 V (TC-ER), 150 V (NPLF).
- UL temperature: 90°C dry, 90°C wet; operating temperature: wet/dry: -30°C to 90°C.
- Environmental suitability: indoor, outdoor, sunlight resistance, burial; sun resistance: SUN RES; direct burial: DIR BUR.
Belden 28110A Technical Specs
Construction & Materials
| Product type | VNTC control |
|---|---|
| Conductor type | Stranded |
| Color code | Black, Red, Blue |
| Armor | No |
| Composite | No |
Dimensions & Weight
| Insulation nominal thickness | 0.022 in (0.56 mm) |
|---|---|
| Insulation nominal diameter | 0.134 in (3.40 mm) |
| Outer jacket nominal thickness | 0.047 in (1.2 mm) |
| Outer jacket nominal diameter | 0.382 in (9.70 mm) |
| Bulk cable weight | 103 lbs/1000ft |
Electrical Characteristics
| Nom. conductor DCR | 1.68 Ohm/1000ft |
|---|---|
| Max. current | 30 Amps per Conductor at 30ºC |
Mechanical Ratings
| Bend radius (stationary min.) | 1.52 in (38.6 mm) |
|---|---|
| Bend radius (installation min.) | 1.9 in (48 mm) |
| Max. pull tension | 260.4 lbs (118.1 kg) |
Compliance & Certifications
| Flammability / reaction to fire | UL 1685 UL loading, IEEE 1202 FT4 |
|---|---|
| NEC / UL compliance | Article 336, Article 760, NPLF, TC-ER, THWN-2 Singles |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2) |
Belden 28110A Applications
- Use in power and control applications up to 600 V where a UL Type TC (1277) VNTC control cable is required.
- Specify for Class 1 Division 2 hazardous locations.
- Select Belden BTC075A0551RA as the recommended cable gland.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Product type | VNTC control |
| Conductor Type | Stranded |
| Color Code | Black, Red, Blue |
| Armor | No |
| Composite | No |
| Insulation nominal thickness | 0.022 in (0.56 mm) |
| Insulation nominal diameter | 0.134 in (3.40 mm) |
| Outer jacket nominal thickness | 0.047 in (1.2 mm) |
| Outer jacket nominal diameter | 0.382 in (9.70 mm) |
| Bulk cable weight | 103 lbs/1000ft |
| Nom. conductor DCR | 1.68 Ohm/1000ft |
| Max. current | 30 Amps per Conductor at 30ºC |
| Bend radius (stationary min.) | 1.52 in (38.6 mm) |
| Bend radius (installation min.) | 1.9 in (48 mm) |
| Max Pull Tension | 260.4 lbs (118.1 kg) |
| Flammability / reaction to fire | UL 1685 UL loading, IEEE 1202 FT4 |
| NEC / UL compliance | Article 336, Article 760, NPLF, TC-ER, THWN-2 Singles |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2) |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.