Belden 28111A, Control Cable 4C 12 AWG PVC NYL 600V UL TC ER

SKU:Belden 28111A
● Auf Lager
Beschreibung
Belden 28111A is a VNTC Control cable with 4 conductors of 12 AWG and a black PVC Outer Jacket. It features 7x20 BC - Bare Copper conductors with PVC-NYL Insulation and is unshielded. This cable is rated 600 V (TC-ER), 150 V (NPLF) and 90°C Dry, 90°C Wet, with an operating Wet/Dry range of -30°C to 90°C. It is listed for Indoor, Outdoor, Sunlight Resistance, Burial and includes a ripcord for easier jacket removal.
Belden 28111A Key Features
- UL type: UL Type TC (1277) PVC-Nylon/PVC.
- Product type: VNTC Control.
- Conductor stranding and material: 7x20 BC - Bare Copper.
- Insulation system: PVC-NYL Insulation E2 Color Code with color code Black, Red, Blue, Orange.
- Voltage ratings: 600 V (TC-ER), 150 V (NPLF) and voltage range 600 V.
- Temperature ratings: 90°C Dry, 90°C Wet; Operating Wet/Dry: -30°C to 90°C.
- Environmental suitability: Indoor, Outdoor, Sunlight Resistance, Burial; Environmental: SUN RES DIR BUR.
- Ripcord: Yes.
Belden 28111A Technical Specs
Construction & Materials
| Number of conductors | 4 |
|---|---|
| Conductor size | 12 AWG |
| Shield | Unshielded |
| Armor | No |
| Composite | No |
| Earth/ground wires | No |
| Insulation material | PVC/Nylon - Polyvinyl Chloride + Nylon |
| Insulation nom. thickness | 0.022 in (0.56 mm) |
| Nom. insulation diameter | 0.123 in (3.12 mm) |
| Jacket material | PVC - Polyvinyl Chloride |
| Jacket color | Black PVC Outer Jacket |
| Jacket nom. thickness | 0.047 in (1.2 mm) |
| Nom. diameter | 0.417 in (10.6 mm) |
Electrical Characteristics
| Nom. conductor DCR | 1.68 Ohm/1000ft |
|---|---|
| Max. current | 24 Amps per Conductor at 30ºC |
Mechanical & Handling
| Stationary min. bend radius | 1.64 in (41.7 mm) |
|---|---|
| Installation min. bend radius | 2.05 in (52.1 mm) |
| Max. pull tension | 347.2 lbs (157.5 kg) |
| Bulk cable weight | 132 lbs/1000ft |
Flammability, Compliance & Certifications
| Flammability / reaction to fire | UL 1685 UL loading, IEEE 1202 FT4 |
|---|---|
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 336, Article 760, NPLF, TC-ER, THWN-2 Singles |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
Belden 28111A Applications
- Use for power and control applications up to 600V.
- It is specified for Class 1 Division 2 hazardous locations.
- Select Belden BTC075A0551RA as the recommended cable gland.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Number of Conductors | 4 |
| Conductor size | 12 AWG |
| Shield | Unshielded |
| Armor | No |
| Composite | No |
| Earth/ground wires | No |
| Insulation Material | PVC/Nylon - Polyvinyl Chloride + Nylon |
| Insulation nom. thickness | 0.022 in (0.56 mm) |
| Nom. insulation diameter | 0.123 in (3.12 mm) |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket Color | Black PVC Outer Jacket |
| Jacket nom. thickness | 0.047 in (1.2 mm) |
| Nom. diameter | 0.417 in (10.6 mm) |
| Nom. conductor DCR | 1.68 Ohm/1000ft |
| Max. current | 24 Amps per Conductor at 30ºC |
| Stationary min. bend radius | 1.64 in (41.7 mm) |
| Installation min. bend radius | 2.05 in (52.1 mm) |
| Max Pull Tension | 347.2 lbs (157.5 kg) |
| Bulk cable weight | 132 lbs/1000ft |
| Flammability / reaction to fire | UL 1685 UL loading, IEEE 1202 FT4 |
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 336, Article 760, NPLF, TC-ER, THWN-2 Singles |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.