Belden 28329AS 010, Control Cable 18 AWG 12C Foil Shield 600V PVC NYL, Black Jacket

SKU:Belden 28329AS 010
● Auf Lager
Beschreibung
Belden 28329AS 010 is a 12 conductor 18 AWG control cable for power and control applications up to 600V. It features PVC/Nylon insulation with E2 color coding and an overall Beldfoil® tape shield with 100% coverage. Built to UL Type TC (1277) PVC-Nylon/PVC, it is rated 600 V (TC-ER) and 150 V (NPLF), with 90°C Dry and 90°C Wet temperature performance. A black PVC outer jacket with ripcord supports easier stripping and is listed for Indoor, Outdoor, Sunlight Resistance, and Burial environments.
Belden 28329AS 010 Key Features
- 12 conductor 18 AWG stranded construction with 7x26 stranding and BC - Bare Copper conductor material.
- PVC/Nylon - Polyvinyl Chloride + Nylon insulation with E2 color coding for conductor identification.
- Overall Beldfoil® shield tape design with Bi-Laminate (Alum+Poly) material and 100% coverage.
- UL voltage rating: 600 V (TC-ER), 150 V (NPLF).
- UL temperature: 90°C Dry, 90°C Wet; operating: Wet/Dry: -30°C to 90°C.
- Black PVC - Polyvinyl Chloride outer jacket with ripcord: Yes.
- UL type: UL Type TC (1277) PVC-Nylon/PVC.
Belden 28329AS 010 Technical Specs
Construction & Materials
| Product type | VNTC CONTROL |
|---|---|
| Conductor type | Stranded |
| Earth/ground wires | No |
| Insulation nominal thickness | 0.020 in (0.51 mm) |
| Insulation nominal diameter | 0.087 in (2.2 mm) |
| Color code | Black, Red, Blue, Orange, Yellow, Brown, Red/Black, Blue/Black, Orange/Black, Yellow/Black, Brown/Black, Black/Red |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Drainwire type | 18 AWG (7x26) TC |
| Armor | No |
| Composite | No |
Electrical Characteristics
| Nom outer Shield DCR | 4.57 Ohm/1000ft (15.0 Ohm/km) |
|---|---|
| Nom. Conductor DCR | 6.7 Ohm/1000ft |
| Max. current | 24 Amps per Conductor at 30ºC |
Dimensions & Mechanical Specs
| Jacket nominal thickness | 0.047 in (1.2 mm) |
|---|---|
| Nominal diameter | 0.459 in (11.7 mm) |
| Overall cable diameter (nominal) | 0.459 in (11.7 mm) |
| Bend radius (stationary min.) | 5.508 in (139.9 mm) |
| Bend radius (installation min.) | 5.508 in (139.9 mm) |
| Max. pull tension | 284 lbs (129 kg) |
| Bulk cable weight | 141 lbs/1000ft |
Compliance, Flammability & Environmental
| NEC / UL compliance | Article 336, Article 400, Article 760, TC-ER, NPLF, TFFN |
|---|---|
| Flammability / reaction to fire | UL1685 UL Loading, IEEE 1202 FT4 |
| Environmental suitability | Indoor, Outdoor, Sunlight Resistance, Burial |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
Belden 28329AS 010 Applications
- Use it for power and control applications up to 600V where a control cable is required.
- Install it in Indoor and Outdoor environments when the application calls for Sunlight Resistance.
- Select it for burial environments when the installation specifies Burial suitability.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Product type | VNTC CONTROL |
| Conductor Type | Stranded |
| Earth/ground wires | No |
| Insulation nominal thickness | 0.020 in (0.51 mm) |
| Insulation nominal diameter | 0.087 in (2.2 mm) |
| Color Code | Black, Red, Blue, Orange, Yellow, Brown, Red/Black, Blue/Black, Orange/Black, Yellow/Black, Brown/Black, Black/Red |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Drainwire type | 18 AWG (7x26) TC |
| Armor | No |
| Composite | No |
| Nom. outer shield DCR | 4.57 Ohm/1000ft (15.0 Ohm/km) |
| Nom. conductor DCR | 6.7 Ohm/1000ft |
| Max. current | 24 Amps per Conductor at 30ºC |
| Jacket nominal thickness | 0.047 in (1.2 mm) |
| Nominal diameter | 0.459 in (11.7 mm) |
| Overall cable diameter (nominal) | 0.459 in (11.7 mm) |
| Bend radius (stationary min.) | 5.508 in (139.9 mm) |
| Bend radius (installation min.) | 5.508 in (139.9 mm) |
| Max Pull Tension | 284 lbs (129 kg) |
| Bulk cable weight | 141 lbs/1000ft |
| NEC / UL compliance | Article 336, Article 400, Article 760, TC-ER, NPLF, TFFN |
| Flammability / reaction to fire | UL1685 UL Loading, IEEE 1202 FT4 |
| Environmental suitability | Indoor, Outdoor, Sunlight Resistance, Burial |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.