Belden 29503F 010, VFD Cable 3C 10 AWG Shielded 1000V TPE, Black Jacket

SKU:Belden 29503F 010
● Auf Lager
Beschreibung
Belden 29503F 010 is a shielded VFD cable for Variable Frequency Drives (VFD) and AC motor/drive systems where high flex, motion, and abrasion are common. It is built with 3 x 10 AWG TC - Tinned Copper conductors plus a 1 x 10 AWG TC - Tinned Copper ground, using XLPE - Cross-Linked Polyethylene (Thermoset) insulation and a black TPE - Thermoplastic Elastomer jacket. The overall shield combines Beldfoil® tape and an 85% Tinned Copper braid with a 10 AWG Tinned Copper drain to support noise control and signal integrity in demanding VFD environments. It is rated 600/1000V and 90°C Dry/Wet, with environmental suitability for Indoor, Outdoor, Sunlight Resistance, Oil Resistance, and Burial.
Belden 29503F 010 Key Features
- Type: 300% Ground Extra Flexible VFD.
- Conductors: 3 x 10 AWG, TC - Tinned Copper, with conductor stranding: 7x37x34.
- Ground: 1 x 10 AWG, 7x37x34, TC - Tinned Copper, with ground insulation: PVC - Polyvinyl Chloride.
- Insulation: XLPE - Cross-Linked Polyethylene (Thermoset), with conductor color code: Black and Numbered.
- Shielding: Beldfoil® + Tinned Copper Braid (85%) shield w/10AWG Tinned Copper drain.
- Jacket: TPE - Thermoplastic Elastomer, jacket color: Black.
- Voltage: 600/1000V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable 1000V WTTC 600V CIC TC SUN RES OIL RES II DIR BUR.
- UL temperature: 90°C Dry, 90°C Wet.
- Environmental suitability: Indoor, Outdoor, Sunlight Resistance, Oil Resistance, Burial.
Belden 29503F 010 Technical Specs
Construction & Materials
| Ripcord | Yes |
|---|---|
| Conductor insulation thickness (nominal) | 0.046 in (1.2 mm) |
| Ground insulation thickness (nominal) | 0.046 in (1.2 mm) |
| Ground color code | Green/Yellow Stripe |
| Tape shield material | Tri-Laminate (Alum+Poly+Alum) |
| Tape coverage | 100% |
| Braid shield material | Tinned Copper (TC) |
| Shield type | Shielded |
| Jacket thickness (nominal) | 0.073 in (1.9 mm) |
| Overall cable diameter (nominal) | 0.716 in (18.2 mm) |
Electrical Ratings & Performance
| UL voltage rating | 1000 V (TC, WTTC, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC) |
|---|---|
| Nom. conductor DCR | 1.003 Ohm/1000ft (3.291 Ohm/km) |
| Nom. capacitance Cond-to-Cond | 45 pF/ft (150 pF/m) |
| Nom. capacitance Cond-to-other (conds + Shield) | 81 pF/ft (270 pF/m) |
| Nom. characteristic impedence | 41 Ohm |
| Nom. inductance | 0.184 μH/ft (0.604 μH/m) |
| Nom. velocity of prop. | 55% |
| Max. current | 40 Amps per Conductor at 30ºC (per NEC) |
Environmental & Mechanical Ratings
| Operating temperature | -40°C To +90°C |
|---|---|
| Bend radius (stationary min.) | 3.6 in (91 mm) |
| Bend radius (installation min.) | 5.4 in (140 mm) |
| Bend radius (flexing min.) | 5.4 in |
| Max. pull tension | 666 lbs (302 kg) |
| Bulk cable weight | 357 lbs/1000ft (531 kg/km) |
| Flammability / reaction to fire | UL1685 UL Loading, FT4, 1202, 383 Vertical Tray Flame Test (70,000 BTU) |
Compliance & Certifications
| NEC / UL compliance | Article 336, TC-ER, XHHW-2, RHW-2, UL Flexible Motor Supply Cable |
|---|---|
| CEC / C(UL) compliance | CIC, TC |
| ICEA compliance | S-95-658 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
Belden 29503F 010 Applications
- Designed for Variable Frequency Drives (VFD) where a shielded motor supply cable is needed.
- Supports AC motor and drive systems in installations that require a flexible cable design.
- Works well in environments where high flex, motion, and abrasion are common.
- Suitable for hard to reach installation areas where pliable handling can help during routing.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Ripcord | Yes |
| Conductor insulation thickness (nominal) | 0.046 in (1.2 mm) |
| Ground insulation thickness (nominal) | 0.046 in (1.2 mm) |
| Ground color code | Green/Yellow Stripe |
| Tape shield material | Tri-Laminate (Alum+Poly+Alum) |
| Tape coverage | 100% |
| Braid shield material | Tinned Copper (TC) |
| Shield Type | Shielded |
| Jacket thickness (nominal) | 0.073 in (1.9 mm) |
| Overall cable diameter (nominal) | 0.716 in (18.2 mm) |
| UL Voltage Rating | 1000 V (TC, WTTC, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC) |
| Nom. conductor DCR | 1.003 Ohm/1000ft (3.291 Ohm/km) |
| Nom. capacitance cond-to-cond | 45 pF/ft (150 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 81 pF/ft (270 pF/m) |
| Nom. characteristic impedence | 41 Ohm |
| Nom. inductance | 0.184 µH/ft (0.604 µH/m) |
| Nom. velocity of prop. | 55% |
| Max. current | 40 Amps per Conductor at 30ºC (per NEC) |
| Operating temperature | -40°C To +90°C |
| Bend radius (stationary min.) | 3.6 in (91 mm) |
| Bend radius (installation min.) | 5.4 in (140 mm) |
| Bend radius (flexing min.) | 5.4 in |
| Max Pull Tension | 666 lbs (302 kg) |
| Bulk cable weight | 357 lbs/1000ft (531 kg/km) |
| Flammability / reaction to fire | UL1685 UL Loading, FT4, 1202, 383 Vertical Tray Flame Test (70,000 BTU) |
| NEC / UL compliance | Article 336, TC-ER, XHHW-2, RHW-2, UL Flexible Motor Supply Cable |
| CEC / C(UL) compliance | CIC, TC |
| ICEA compliance | S-95-658 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?