Belden 29522C 010, VFD-Kabel, 3C-12 AWG BC + 3G-16 AWG BC, XLPE, geschirmt, schwarzer Mantel

SKU:Belden 29522C 010
$364.80
● Auf Lager
Beschreibung
Belden 29522C 010, VFD-Kabel, 3C-12 AWG BC + 3G-16 AWG BC, XLPE, geschirmt, schwarzer Mantel
Belden Basics 600V Frequenzumrichter
3-12 AWG verseilte (7x20) blanke Kupferleiter + 3-16 AWG symmetrische segmentierte Erdungsdrähte aus blankem Kupfer
VPE-Isolierung an den Leitern, M4-Farbcode
Insgesamt zwei Kupferbänder, spiralförmig aufgebrachte Abschirmung
Overall PVC-Jacke, Reißleine
600/1000 V TC-ER, 90ºC Nass/Trocken
Spezifikationen
| Attribute | Value |
|---|---|
| Number of Conductors | 3 |
| Conductor size | 12 AWG |
| Conductor stranding | 7x20 |
| Conductor Material | BC - Bare Copper |
| Segmented ground wire | 3 x 16 AWG |
| Ground stranding | 7x24 |
| Ground material | BC - Bare Copper |
| Ground notes | 3 Ground Segments totaling 12 AWG |
| Insulation Material | XLPE - Cross-Linked Polyethylene (Thermoset) |
| Nom. thickness | 0.030 in (0.76 mm) |
| Nom. insulation diameter | 0.153 in (3.89 mm) |
| Color Code | ICEA Chart M4 |
| Ground wire insulation | No Insulation |
| Shield Type | Helical Tape |
| Shield Material | Bare Copper (BC) |
| Coverage | 100% |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Jacket Color | Black |
| Nom. jacket thickness | 0.060 in (1.5 mm) |
| Nom. conductor DCR | 1.423 Ohm/1000ft (4.669 Ohm/km) |
| Nom. capacitance cond-to-cond | 29 pF/ft (95 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 56 pF/ft (180 pF/m) |
| Nom. characteristic impedence | 50 Ohm |
| Nom. velocity of prop. | 55% |
| Max. current | 30 Amps per Conductor at 30ºC |
| Nom. outer shield DCR | 0.97 Ohm/1000ft (3.2 Ohm/km) |
| Nom. diameter | 0.460 in (11.7 mm) |
| Stationary min. bend radius | 5.5 in (140 mm) |
| Installation min. bend radius | 5.5 in (140 mm) |
| Max Pull Tension | 283 lbs (128 kg) |
| Bulk cable weight | 191 lbs/1000ft (284 kg/km) |
| Sustainability | CA Prop 65 |
| Flammability / reaction to fire | UL 1685 UL Loading, IEEE 1202 FT4 |
| NEC / UL compliance | Article 336, TC-ER |
| ICEA compliance | S-95-658 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-07-KA070003-MSHA |
| Other Part Numbers | 29522C 010, 29522C 010100, 29522C 010250, 29522C 010500, 29522C 0101000 |
| Priced Per | FT |
Dokumente
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.