Belden 29524C is a Belden Basics VFD cable designed for Variable Frequency Drives (VFD), AC motor and drive systems, and Class 1 Division 2 hazardous locations. It features 3 circuit conductors of 8 AWG stranded (7x16) bare copper with XLPE insulation and ICEA Chart M4 color coding, plus a 10AWG symmetrical segmented ground made from (3) of 14AWG bare copper strands. For noise control and grounding continuity, it uses an overall dual copper tape helically applied shield with 100% coverage. The cable is finished with a black PVC outer jacket with ripcord and carries 600 / 1000 V (TC-ER) and 90°C Dry, 90°C Wet ratings, along with SUN RES, DIR BUR, and Oil Resistant markings.
Belden 29524C Key Features
- 3 circuit conductors of 8 AWG stranded (7x16) bare copper with XLPE insulation and ICEA Chart M4 color coding.
- 10AWG symmetrical segmented ground made from (3) of 14AWG bare copper strands.
- Overall dual copper tape helically applied shield with 100% coverage for noise control and grounding continuity.
- Black PVC outer jacket with ripcord for easier jacket removal during installation.
- Rated 600 / 1000 V (TC-ER) and 90°C Dry, 90°C Wet, with SUN RES, DIR BUR, and Oil Resistant markings.
Belden 29524C Technical Specs
Conductors, Ground, Shield & Materials
| Number of conductors | 3 |
|---|---|
| Conductor size | 8 AWG |
| Conductor stranding | 7x16 |
| Conductor material | BC - Bare Copper |
| Conductor notes | ASTM B3 Copper B8 Class B Stranding |
| Segmented ground wire | 3 x 14 AWG |
| Ground stranding | 7x22 |
| Ground material | BC - Bare Copper |
| Ground notes | Segmented Ground (3 Totaling 10+ AWG) |
| Insulation material | XLPE - Cross-Linked Polyethylene (Thermoset) |
| Nom. thickness | 0.047 in (1.2 mm) |
| Nom. insulation diameter | 0.236 in (5.99 mm) |
| Ground wire | No Insulation |
| Shield type | Helical Tape |
| Shield material | Bare Copper (BC) |
Jacket & Physical Dimensions
| Jacket material | PVC - Polyvinyl Chloride |
|---|---|
| Jacket color | Black |
| Nom. jacket thickness | 0.063 in (1.6 mm) |
| Nom. diameter | 0.646 in (16.4 mm) |
| Overall cable diameter (nominal) | 0.646 in (16.4 mm) |
| Bulk cable weight | 350 lbs/1000ft (520 kg/km) |
Performance & Electrical Characteristics
| Nom. conductor DCR | 0.564 Ohm/1000ft (1.85 Ohm/km) |
|---|---|
| Nom. capacitance cond-to-cond | 31 pF/ft (100 pF/m) |
| Nom. capacitance cond-to-other (conds + shield) | 63 pF/ft (210 pF/m) |
| Nom. characteristic impedence | 50 Ohm |
| Nom. velocity of prop. | 55% |
| Max. current | 55 Amps per Conductor at 30ºC |
| Nom outer shield DCR | 0.81 Ohm/1000ft (2.7 Ohm/km) |
Environmental & Mechanical Ratings
| Operating | -40°C To +90°C |
|---|---|
| Stationary min. bend radius | 7.8 in (200 mm) |
| Installation min. bend radius | 7.8 in (200 mm) |
| Max. pull tension | 678 lbs (308 kg) |
| Environmental suitability | Indoor, Outdoor, Sunlight Resistance, Burial |
| Additional markings/ratings | 600/1000V TC-ER 90C Dry/Wet 1000V SUN RES DIR BUR Oil Resistant |
Compliance & Certifications
| Flammability / reaction to fire | UL 1685 UL Loading, IEEE 1202 FT4 |
|---|---|
| NEC / UL compliance | Article 336, TC-ER, XHHW-2 |
| ICEA compliance | S-95-658 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-07-KA070003-MSHA |
| Sustainability | CA Prop 65 |
Belden 29524C Applications
- Install in Variable Frequency Drives (VFD) applications where a purpose-built VFD cable is required for drive-to-motor connections.
- Support AC motor and drive systems in industrial installations where consistent electrical performance and grounding are needed.
- Specify for Class 1 Division 2 hazardous locations when the installation requires a cable identified for that environment.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Number of Conductors | 3 |
| Conductor size | 8 AWG |
| Conductor stranding | 7x16 |
| Conductor Material | BC - Bare Copper |
| Conductor notes | ASTM B3 Copper B8 Class B Stranding |
| Segmented ground wire | 3 x 14 AWG |
| Ground stranding | 7x22 |
| Ground material | BC - Bare Copper |
| Ground notes | Segmented Ground (3 Totaling 10+ AWG) |
| Insulation Material | XLPE - Cross-Linked Polyethylene (Thermoset) |
| Nom. thickness | 0.047 in (1.2 mm) |
| Nom. insulation diameter | 0.236 in (5.99 mm) |
| Ground wire | No Insulation |
| Shield Type | Helical Tape |
| Shield Material | Bare Copper (BC) |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket Color | Black |
| Nom. jacket thickness | 0.063 in (1.6 mm) |
| Nom. diameter | 0.646 in (16.4 mm) |
| Overall cable diameter (nominal) | 0.646 in (16.4 mm) |
| Bulk cable weight | 350 lbs/1000ft (520 kg/km) |
| Nom. conductor DCR | 0.564 Ohm/1000ft (1.85 Ohm/km) |
| Nom. capacitance cond-to-cond | 31 pF/ft (100 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 63 pF/ft (210 pF/m) |
| Nom. characteristic impedence | 50 Ohm |
| Nom. velocity of prop. | 55% |
| Max. current | 55 Amps per Conductor at 30ºC |
| Nom. outer shield DCR | 0.81 Ohm/1000ft (2.7 Ohm/km) |
| Operating | -40°C To +90°C |
| Stationary min. bend radius | 7.8 in (200 mm) |
| Installation min. bend radius | 7.8 in (200 mm) |
| Max Pull Tension | 678 lbs (308 kg) |
| Environmental suitability | Indoor, Outdoor, Sunlight Resistance, Burial |
| Additional markings/ratings | 600/1000V TC-ER 90C Dry/Wet 1000V SUN RES DIR BUR Oil Resistant |
| Flammability / reaction to fire | UL 1685 UL Loading, IEEE 1202 FT4 |
| NEC / UL compliance | Article 336, TC-ER, XHHW-2 |
| ICEA compliance | S-95-658 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-07-KA070003-MSHA |
| Sustainability | CA Prop 65 |
| Priced Per | FT |