Belden 29531 010, Frequenzumrichter-Kabel, 3C-3/0 AWG + 3G-4 AWG, XLPE, geschirmt, schwarzer Mantel

SKU:Belden 29531 010
$6,802.80
● Auf Lager
Beschreibung
Belden 29531 010, VFD-Kabel, 3C-3/0 AWG TC + 3G-4 AWG BC, XLPE, geschirmt, schwarzer Mantel
Belden Basics VFD
3-3/0 AWG verseilte (7x19x19) verzinnte Kupferleiter + 3-4 AWG symmetrische blanke Kupfersegment-Erdungsdrähte
VPE-Isolierung an den Leitern, M4-Farbcode
Insgesamt zwei Kupferbänder, spiralförmig aufgebrachte Abschirmung
Overall PVC-Jacke, Reißleine
600/1000 V TC-ER, 90ºC Nass/Trocken
Spezifikationen
| Attribute | Value |
|---|---|
| Number of Conductors | 3 |
| Conductor size | 3/0 AWG |
| Conductor Material | TC - Tinned Copper |
| Conductor stranding | 7x19x19 |
| Ground wires | Yes |
| Number of ground wires | 3 Wire |
| Segmented ground wire | 3 elements, 4 AWG, 7x19x25, BC - Bare Copper |
| Insulation Material (Conductor(s)) | XLPO - Crosslink Polyolefin |
| Nom. thickness | 0.057 in (1.4 mm) |
| Nom. insulation diameter | 0.604 in (15.3 mm) |
| Color Code | ICEA Chart M4 |
| Ground wire insulation | No Insulation |
| Shield | Shielded |
| Shield Type | Copper tape |
| Outer shield type | Helical Tape |
| Outer shield material | Bare Copper (BC) |
| Coverage | 100% |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket Color | Black |
| Nom. jacket thickness | 0.083 in (2.1 mm) |
| Nom. diameter | 1.480 in (37.59 mm) |
| Overall cable diameter (nominal) | 1.480 in (37.59 mm) |
| Ripcord | Yes |
| Voltage range | 1KV |
| UL Voltage Rating | 1000 V (TC, WTTC, UL44, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC) |
| Nom. Conductor DCR (Conductor(s)) | 0.059 Ohm/1000ft (0.19 Ohm/km) |
| Nom. capacitance cond-to-cond | 33 pF/ft (110 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 60 pF/ft (200 pF/m) |
| Nom. characteristic impedence | 56 Ohm |
| Nom. inductance cond-grnd | 0.06 µH/ft |
| Nom. velocity of prop. | 55% |
| Max. current | 225 Amps per Conductor at 30ºC |
| Nom. conductor DCR (segmented ground wire) | 0.06 Ohm/1000ft (0.20 Ohm/km) |
| Nom. outer shield DCR | 0.09 Ohm/1000ft (0.30 Ohm/km) |
| Operating temperature | -40°C To +90°C |
| Bend radius (stationary min.) | 17.8 in (452 mm) |
| Bend radius (installation min.) | 17.8 in (452 mm) |
| Max Pull Tension | 7720 lbs (3500 kg) |
| Bulk cable weight | 2439 lbs/1000ft (3630 kg/km) |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEEE 1202 FT4 |
| NEC / UL compliance | Article 336, TC-ER, WTTC, XHHW-2, UL Flexible Motor Supply Cable |
| CEC / C(UL) compliance | TC |
| ICEA compliance | S-95-658 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-07-KA070003-MSHA |
| Sustainability | CA Prop 65 |
| Product type | VFD |
| Armor | No |
| Composite | No |
| Other Part Numbers | 29531 010, 29531 010100, 29531 010250, 29531 010500, 29531 0101000, UPC 612825138167, UPC 612825138174 |
| Priced Per | FT |