Belden 29532, Multi Conductor 3C4 0 133STC VFD 600V Black

SKU:Belden 29532
● Auf Lager
Beschreibung
Belden 29532 is a 100% ground flexible VFD cable for Variable Frequency Drives (VFD) and AC motor and drive systems, including Class 1 Division 2 hazardous locations. It is built with 3 Stranded 4/0 AWG TC - Tinned Copper conductors, XLPE - Cross-Linked Polyethylene (Thermoset) insulation, and a black PVC - Polyvinyl Chloride outer jacket with ripcord. The design includes a symmetrical segmented ground (3 of 2 AWG) in continuous contact with an overall dual copper tape helical shield for high-frequency performance. It is rated 600/1000V with UL temperature 90°C Dry, 90°C Wet and environmental suitability for Indoor, Outdoor, Sunlight Resistance, Burial.
Belden 29532 Key Features
- 100% ground flexible VFD cable designed for Variable Frequency Drives (VFD) and AC motor and drive systems, including Class 1 Division 2 hazardous locations.
- 3 Stranded 4/0 AWG TC - Tinned Copper conductors with Conductor Stranding: 7x19x18 and Notes: Fine Strand Optomized for VF Applications.
- Symmetrical segmented ground with Earth/ground wires: Yes, Segmented ground Wire: 3, Ground Wire size: 2 AWG, Ground Wire material: BC - Bare Copper, and Ground Wire Stranding: 7x19x23.
- Overall dual copper tape helical shield with Coverage: 100% and Notes: 2 mil helical copper for crack resistance and high frequency performance.
- Black PVC - Polyvinyl Chloride outer jacket with Ripcord: Yes and Environmental suitability: Indoor, Outdoor, Sunlight Resistance, Burial.
- Voltage rating: 600/1000V with UL Voltage Rating: 1000 V (TC, WTTC, UL44, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC) and Voltage range: 1KV.
- Temperature ratings include UL temperature: 90°C Dry, 90°C Wet and Operating: -40°C To +90°C.
Belden 29532 Technical Specs
Construction & Materials
| Number of conductors | 3 |
|---|---|
| Conductor size | 4/0 AWG |
| Conductor material | TC - Tinned Copper |
| Conductor stranding | 7x19x18 |
| Ground wire size | 2 AWG |
| Ground wire material | BC - Bare Copper |
| Ground wire stranding | 7x19x23 |
| Ground notes | Segmented Grounds (3 Totaling 4/0 AWG) |
| Insulation material | XLPE - Cross-Linked Polyethylene (Thermoset) |
| Nom. thickness | 0.057 in (1.4 mm) |
| Nom. insulation diameter | 0.669 in (17.0 mm) |
| Color code | ICEA Chart M4 |
| Shield type | Helical Tape |
| Shield material | Bare Copper (BC) |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Jacket color | Black |
| Nom. jacket thickness | 0.083 in (2.1 mm) |
| Armor | No |
| Composite | No |
Electrical & Signal Characteristics
| Nom. conductor DCR | 0.047 Ohm/1000ft (0.15 Ohm/km) |
|---|---|
| Nom Outer Shield DCR | 0.090 Ohm/1000ft (0.30 Ohm/km) |
| Segmented ground Wire DCR | 0.05 Ohm/1000ft (0.16 Ohm/km) |
| Nom. capacitance Cond-to-Cond | 33 pF/ft (110 pF/m) |
| Nom. capacitance Cond-to-other (Conds + Shield) | 60 pF/ft (200 pF/m) |
| Nom. characteristic impedence | 56 Ohm |
| Nom. inductance Cond-grnd | 0.055 μH/ft |
| Nom. inductance | 0.136 μH/ft (0.446 μH/m) |
| Nom. velocity of prop. | 55% |
| Max. current | 260 Amps per Conductor at 30ºC |
Physical Dimensions & Handling
| Nom. diameter | 1.620 in (41.15 mm) |
|---|---|
| Overall cable diameter (nominal) | 1.620 in (41.15 mm) |
| Stationary min. bend radius | 19.4 in (493 mm) |
| Installation min. bend radius | 19.4 in (493 mm) |
| Max. pull tension | 10048 lbs (4557.7 kg) |
| Bulk cable weight | 3185 lbs/1000ft (4740 kg/km) |
Environmental & Mechanical Ratings
| Flammability / reaction to fire | UL 1685 UL Loading, FT4, IEEE 1202 FT4 |
|---|
Compliance & Certifications
| NEC / UL compliance | Article 336, TC-ER, WTTC, XHHW-2, UL Flexible Motor Supply Cable |
|---|---|
| CEC / C(UL) compliance | TC |
| ICEA compliance | S-95-658 |
| European Directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-07-KA070003-MSHA |
| Sustainability | CA Prop 65 |
Belden 29532 Applications
- Use in Variable Frequency Drives (VFD) where a purpose-built VFD cable is needed for motor power connections.
- Connect AC motor and drive systems in industrial electrical installations.
- Specify for Class 1 Division 2 hazardous locations when the installation requires a cable identified for that environment.
- Recommended cable gland BTC200A1741RA is listed for use with this cable.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Number of Conductors | 3 |
| Conductor size | 4/0 AWG |
| Conductor Material | TC - Tinned Copper |
| Conductor stranding | 7x19x18 |
| Ground wire size | 2 AWG |
| Ground wire material | BC - Bare Copper |
| Ground wire stranding | 7x19x23 |
| Ground notes | Segmented Grounds (3 Totaling 4/0 AWG) |
| Insulation Material | XLPE - Cross-Linked Polyethylene (Thermoset) |
| Nom. thickness | 0.057 in (1.4 mm) |
| Nom. insulation diameter | 0.669 in (17.0 mm) |
| Color Code | ICEA Chart M4 |
| Shield Type | Helical Tape |
| Shield Material | Bare Copper (BC) |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Jacket Color | Black |
| Nom. jacket thickness | 0.083 in (2.1 mm) |
| Armor | No |
| Composite | No |
| Nom. conductor DCR | 0.047 Ohm/1000ft (0.15 Ohm/km) |
| Nom. outer shield DCR | 0.090 Ohm/1000ft (0.30 Ohm/km) |
| Segmented ground Wire DCR | 0.05 Ohm/1000ft (0.16 Ohm/km) |
| Nom. capacitance cond-to-cond | 33 pF/ft (110 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 60 pF/ft (200 pF/m) |
| Nom. characteristic impedence | 56 Ohm |
| Nom. inductance cond-grnd | 0.055 µH/ft |
| Nom. inductance | 0.136 µH/ft (0.446 µH/m) |
| Nom. velocity of prop. | 55% |
| Max. current | 260 Amps per Conductor at 30ºC |
| Nom. diameter | 1.620 in (41.15 mm) |
| Overall cable diameter (nominal) | 1.620 in (41.15 mm) |
| Stationary min. bend radius | 19.4 in (493 mm) |
| Installation min. bend radius | 19.4 in (493 mm) |
| Max Pull Tension | 10048 lbs (4557.7 kg) |
| Bulk cable weight | 3185 lbs/1000ft (4740 kg/km) |
| Flammability / reaction to fire | UL 1685 UL Loading, FT4, IEEE 1202 FT4 |
| NEC / UL compliance | Article 336, TC-ER, WTTC, XHHW-2, UL Flexible Motor Supply Cable |
| CEC / C(UL) compliance | TC |
| ICEA compliance | S-95-658 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-07-KA070003-MSHA |
| Sustainability | CA Prop 65 |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.