Kontakt1-800-975-3686
Ramcorp Wire & Cable

Belden 3082A T5U DeviceBus 2 prs 15+18 AWG TC Gray

Belden 3082A

SKU:Belden 3082A T5U

$485.00

Auf Lager

Beschreibung

Spezifikationen

Belden 3082A T5U DeviceBus 2 prs 15+18 AWG TC Gray specifications
AttributeValue
Conductor count2 PAIRS
Power pair(s)1 pair, 15 AWG, 19x27, TC - Tinned Copper
Data pair(s)1 pair, 18 AWG, 19x30, TC - Tinned Copper
Conductor TypeStranded Conductor
Power pair insulationPVC - Polyvinyl Chloride, 0.021 in (0.53 mm) nominal thickness, 0.109 in (2.77 mm) nominal Insulation Diameter, Red & Black
Data pair insulationPE - Polyethylene (Foam), 0.053 in (1.3 mm) nominal thickness, 0.150 in (3.81 mm) nominal Insulation Diameter, Blue & White, HDPE
Shield constructionIndividual & Overall Braid Shield
Inner shield (power pair(s))Tape, Bi-Laminate (Alum+Poly), 100% coverage
Inner shield (data pair(s))Tape, Bi-Laminate (Alum+Poly), 100% coverage
Outer shieldBraid, Tinned Copper (TC), 65% coverage
Jacket MaterialPVC - Polyvinyl Chloride
Outer jacketPVC - Polyvinyl Chloride, 0.060 in (1.5 mm) nominal thickness
Overall cable diameter (nominal)0.480 in (12.2 mm)
Outer jacket nominal diameter0.480 in (12.2 mm)
Jacket OD +/-+/- 0.010
Bulk cable weight128 lbs/1000ft
Power pair(s) nominal Conductor DCR3.58 Ohm/1000ft
Power pair(s) nominal inner Shield DCR5.75 Ohm/1000ft (18.9 Ohm/km)
Power pair(s) nominal inductance0.174 µH/ft (0.571 µH/m)
Power pair(s) max. current16 Amps per Conductor at 30ºC
Data pair(s) nominal Conductor DCR7.2 Ohm/1000ft (24 Ohm/km)
Data pair(s) nominal inner Shield DCR3.58 Ohm/1000ft (11.7 Ohm/km)
Data pair(s) nominal capacitance Cond-to-Cond12 pF/ft (39 pF/m)
Data pair(s) nominal characteristic impedence120 Ohm
Data pair(s) nominal delay1.36 ns/ft
Data pair(s) nominal velocity of prop.75%
Data pair(s) max. current14 Amps per Conductor at 30ºC
Nom. outer shield DCR7.29 Ohm/1000ft (23.9 Ohm/km)
Voltage Rating300 V (AWM I/II A)
UL temperature60°C
Bend radius (stationary min.)5.76 in (146 mm)
Bend radius (installation min.)5.76 in (146 mm)
Max Pull Tension192.6 lbs (87.36 kg)
NEC / UL complianceArticle 725, Article 800, CMG, PLTC
AWM complianceAWM 20201, AWM I/II A
CEC / C(UL) complianceCMG
Flammability / reaction to fireUL 1685 FT4 Loading, IEEE 1202 FT4, IEC 60332-1-2
CPR complianceCPR Euroclass: Eca
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK regulation complianceUKCA Mark
APAC complianceChina RoHS II (GB/T 26572-2011)
Other standard compliance(s)ODVA Class 2 Thick
Item TypeBelden Multi Conductor Cable
Other Part Numbers3082A T5U, 3082A T5U100, 3082A T5U250, 3082A T5U500, 3082A T5U1000
Priced PerFT

Dokumente

Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.

Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?

Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.