Belden 5000UL 002, Multi Conductor Commercial Audio 2C 12 AWG PVC

SKU:Belden 5000UL 002
● Auf Lager
Beschreibung
Belden 5000UL 002 is a 2-conductor 12 AWG Fire Alarm Riser Cable (FPLR) for monitor/detection circuits, including audio, control, initiating, and notification. It features 12 AWG stranded bare copper conductors with PP - Polypropylene insulation and a PVC - Polyvinyl Chloride jacket. This indoor-rated riser cable is UL 300 V and 75°C, and includes a ripcord plus sequential footage marking every two feet for easier installation and identification.
Key Features
- Fire Alarm Riser Cable (FPLR) for monitor/detection circuits, including audio, control, initiating, and notification.
- 2 conductors, 12 AWG stranded bare copper conductors with PP - Polypropylene insulation.
- PVC - Polyvinyl Chloride jacket with ripcord for easier jacket removal.
- Sequential footage marking every two feet for straightforward measuring and pull tracking.
- Indoor suitability with riser fire rating; flammability / reaction to fire: UL1666 Riser, IEEE 1202 FT4.
Technical Specs
Construction & Materials
| Conductor element | pair(s), 1 |
|---|---|
| Conductor stranding | 19x25 |
| Insulation thickness (nom.) | 0.011 in (0.28 mm) |
| Insulation diameter (nom.) | 0.113 in (2.87 mm) |
| Color code | Black & Red |
| Outer shield | No Shield |
| Jacket thickness (nom.) | 0.017 in (0.43 mm) |
Dimensions & Weight
| Overall cable diameter (nom.) | 0.26 in |
|---|---|
| Nom. Diameter | 0.26 in |
| Bulk Cable Weight | 51 lbs/1000ft |
Electrical Characteristics
| Nom. Conductor DCR | 1.72 Ohm/1000ft |
|---|---|
| Nom. capacitance Cond-to-Cond | 23.75 pF/ft (77.92 pF/m) |
| Max. current | 12 Amps per Conductor at 25ºC |
Environmental & Mechanical Ratings
| Operating temperature | -20°C to +75°C |
|---|---|
| Bend Radius (stationary min.) | 2.08 in (52.8 mm) |
| Bend Radius (installation min.) | 2.08 in |
| Max. pull tension | 152 lbs (68.9 kg) |
Compliance & Certifications
| NEC / UL compliance | Article 760, FPLR |
|---|---|
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Plenum number | 6000UL |
Applications
- Use in fire alarm monitor/detection circuits requiring audio, control, initiating, and notification functions.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Conductor element | pair(s), 1 |
| Conductor stranding | 19x25 |
| Insulation thickness (nom.) | 0.011 in (0.28 mm) |
| Insulation diameter (nom.) | 0.113 in (2.87 mm) |
| Color Code | Black & Red |
| Outer shield | No Shield |
| Jacket thickness (nom.) | 0.017 in (0.43 mm) |
| Overall cable diameter (nom.) | 0.26 in |
| Nom. diameter | 0.26 in |
| Bulk cable weight | 51 lbs/1000ft |
| Nom. conductor DCR | 1.72 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 23.75 pF/ft (77.92 pF/m) |
| Max. current | 12 Amps per Conductor at 25ºC |
| Operating temperature | -20°C to +75°C |
| Bend radius (stationary min.) | 2.08 in (52.8 mm) |
| Bend radius (installation min.) | 2.08 in |
| Max Pull Tension | 152 lbs (68.9 kg) |
| NEC / UL compliance | Article 760, FPLR |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Plenum number | 6000UL |
| Priced Per | FT |