Belden 5140F1 010, 1 FS PR 14 AWG Multi Conductor PVC PVC Black

SKU:Belden 5140F1 010
● Auf Lager
Beschreibung
Belden 5140F1 010 is a security & sound cable with 1 pair of 14 AWG stranded TC - Tinned Copper conductors and PVC - Polyvinyl Chloride insulation. It features a Bi-Laminate (Alum+Poly) tape shield with 100% coverage, along with a 16 AWG (19x29) TC drainwire and Waterblock Tape for moisture protection. Rated-CL3-FPL-PLTC and UL 300 V (CL3, FPL, PLTC-ER), it is specified for Indoor/Outdoor, Sunlight Resistance, and Burial environments.
Key Features
- It uses a 1 pair construction with 14 AWG stranded TC - Tinned Copper conductors (19x26).
- PVC - Polyvinyl Chloride insulation is color coded Black & Red.
- A Bi-Laminate (Alum+Poly) tape shield provides 100% coverage for noise immunity.
- It includes a 16 AWG (19x29) TC drainwire and Waterblock Tape for wet or below-grade duct environments.
- Rated-CL3-FPL-PLTC and UL 300 V (CL3, FPL, PLTC-ER).
Technical Specs
Construction & Materials
| Elements | Pair(s) |
|---|---|
| No. of elements | 1 |
| Insulation thickness (nom.) | 0.014 in (0.36 mm) |
| Insulation diameter (nom.) | 0.104 in (2.64 mm) |
| Jacket material | PVC - Polyvinyl Chloride |
| Jacket thickness (nom.) | 0.042 in (1.1 mm) |
| Overall diameter (nom.) | 0.326 in (8.28 mm) |
Electrical Characteristics
| Nom. Conductor DCR | 3.05 Ohm/1000ft (10.0 Ohm/km) |
|---|---|
| Nom. capacitance Cond-to-Cond | 83 pF/ft (270 pF/m) |
| Max. current | 29 Amps per Conductor @ 30°C |
| Nom outer Shield DCR | 4.18 Ohm/1000ft (13.7 Ohm/km) |
Temperature, Mechanical & Handling
| UL temperature | 90°C |
|---|---|
| Operating temperature | -20°C to +90°C |
| Bend radius (stationary min.) | 3.3 in (84 mm) |
| Bend radius (installation min.) | 3.3 in (84 mm) |
| Max. pull tension | 135 lbs (61.2 kg) |
| Bulk cable weight | 61 lbs/1000ft (91 kg/km) |
Compliance, Fire Ratings & Directives
| NEC / UL compliance | Article 725, Article 760, Article 800, CL3, FPL, PLTC |
|---|---|
| CEC / C(UL) compliance | CL3 |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEEE 1202 FT4, IEC 60332-1-2 |
| CPR Euroclass | Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Environmental & Sustainability
| Environmental suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial |
|---|---|
| Sustainability | Product Lens™, Environmental Product Declaration (EPD) Available |
Applications
- It is designed for security system wiring where shielded construction and moisture protection are needed.
- Intercom/PA installations can benefit from its noise immunity.
- Audio/speaker runs may use shielding to help reduce interference.
- It is specified for Fire Alarm (Red Jkt) applications.
- Power-limited controls can use it where CL3/FPL/PLTC ratings are required.
- Noisy & wet location installations are supported.
- Below-grade duct routing is appropriate where Waterblock Tape is specified.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Elements | Pair(s) |
| No. of elements | 1 |
| Insulation thickness (nom.) | 0.014 in (0.36 mm) |
| Insulation diameter (nom.) | 0.104 in (2.64 mm) |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket thickness (nom.) | 0.042 in (1.1 mm) |
| Overall diameter (Nom.) | 0.326 in (8.28 mm) |
| Nom. conductor DCR | 3.05 Ohm/1000ft (10.0 Ohm/km) |
| Nom. capacitance cond-to-cond | 83 pF/ft (270 pF/m) |
| Max. current | 29 Amps per Conductor @ 30°C |
| Nom. outer shield DCR | 4.18 Ohm/1000ft (13.7 Ohm/km) |
| UL temperature | 90°C |
| Operating temperature | -20°C to +90°C |
| Bend radius (stationary min.) | 3.3 in (84 mm) |
| Bend radius (installation min.) | 3.3 in (84 mm) |
| Max Pull Tension | 135 lbs (61.2 kg) |
| Bulk cable weight | 61 lbs/1000ft (91 kg/km) |
| NEC / UL compliance | Article 725, Article 760, Article 800, CL3, FPL, PLTC |
| CEC / C(UL) compliance | CL3 |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEEE 1202 FT4, IEC 60332-1-2 |
| CPR Euroclass | Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Environmental suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial |
| Sustainability | Product Lens™, Environmental Product Declaration (EPD) Available |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.