Belden 5200UE 009U, Multi Conductor Audio Cable 2C 16 AWG FRPVC White

SKU:Belden 5200UE 009U
● Auf Lager
Beschreibung
Belden 5200UE 009U is a security and commercial audio cable designed for indoor riser (CMR) installations requiring 2-conductor performance. It features 2-16 AWG stranded bare copper conductors with polypropylene insulation and a PVC jacket with a ripcord for easier stripping. The cable is UL 1666 Riser and FT4 rated, with a 300 V (CMR) UL voltage rating and a 75°C UL temperature rating.
Key Features
- 2-16 AWG stranded bare copper conductors for signal and control use.
- Polypropylene insulation with a PVC jacket.
- Includes a ripcord for easier stripping.
- UL 1666 Riser and FT4 flammability / reaction to fire ratings.
- 300 V (CMR) UL voltage rating and 75°C UL temperature rating.
Technical Specs
Construction & Materials
| Number of conductors | 2 |
|---|---|
| Conductor size | 16 AWG |
| Conductor stranding | 19x29 |
| Conductor material | BC - Bare Copper |
| Insulation material | PO - Polyolefin |
| Insulation nominal thickness | 0.008 in (0.20 mm) |
| Insulation nominal diameter | 0.073 in (1.9 mm) |
| Conductor color code | Black, Red |
| Jacket material | PVC - Polyvinyl Chloride |
| Jacket nominal thickness | 0.017 in (0.43 mm) |
Electrical Characteristics
| Nominal conductor DCR | 4.2 Ohm/1000ft |
|---|---|
| Nominal capacitance (cond-to-cond) | 23 pF/ft (75 pF/m) |
| Nominal inductance | 0.14 μH/ft (0.46 μH/m) |
| Max. current | 6.25 Amps per Conductor @ 25°C |
Physical, Mechanical & Environmental
| Overall cable diameter (nominal) | 0.180 in (4.57 mm) |
|---|---|
| Operating temperature | -20°C to +75°C |
| Minimum bend radius (stationary) | 1.8 in (46 mm) |
| Minimum bend radius (installation) | 1.8 in (46 mm) |
| Max. pull tension | 59 lbs (27 kg) |
| Bulk cable weight | 24 lbs/1000ft |
| Environmental suitability | Indoor - Riser, Indoor |
Compliance & Certifications
| NEC / UL compliance | Article 800, CMR |
|---|---|
| CEC / C(UL) compliance | CMG |
| Flammability / reaction to fire | UL 1666 Riser, FT4, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Additional Reference
| Plenum number | 6200UE |
|---|
Applications
- Supports data circuits where consistent signal and control performance is required.
- Commonly used in monitor/detection circuits for system status and event monitoring.
- Fits control circuits that need dependable 2-conductor connectivity.
- Suitable for initiating circuits in security and commercial audio system designs.
- Works in notification circuits where signal transmission is needed for alerts and indications.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Number of Conductors | 2 |
| Conductor size | 16 AWG |
| Conductor stranding | 19x29 |
| Conductor Material | BC - Bare Copper |
| Insulation Material | PO - Polyolefin |
| Insulation nominal thickness | 0.008 in (0.20 mm) |
| Insulation nominal diameter | 0.073 in (1.9 mm) |
| Conductor color code | Black, Red |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket nominal thickness | 0.017 in (0.43 mm) |
| Nominal conductor DCR | 4.2 Ohm/1000ft |
| Nominal capacitance (Cond-to-Cond) | 23 pF/ft (75 pF/m) |
| Nominal inductance | 0.14 µH/ft (0.46 µH/m) |
| Max. current | 6.25 Amps per Conductor @ 25°C |
| Overall cable diameter (nominal) | 0.180 in (4.57 mm) |
| Operating temperature | -20°C to +75°C |
| Minimum bend radius (stationary) | 1.8 in (46 mm) |
| Minimum bend radius (installation) | 1.8 in (46 mm) |
| Max Pull Tension | 59 lbs (27 kg) |
| Bulk cable weight | 24 lbs/1000ft |
| Environmental suitability | Indoor - Riser, Indoor |
| NEC / UL compliance | Article 800, CMR |
| CEC / C(UL) compliance | CMG |
| Flammability / reaction to fire | UL 1666 Riser, FT4, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Plenum number | 6200UE |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.