Belden 5302F1 010, Multi Conductor 4C 18 AWG PVC FS PVC Black

SKU:Belden 5302F1 010
● Auf Lager
Beschreibung
Belden 5302F1 010 is a security & sound cable rated-CMG-FPL-PLTC with 4 conductors in 18 AWG stranded tinned copper and PVC insulation. It includes waterblock tape and a tape shield with 100% coverage, plus an overall drain wire to support noise rejection. The PVC jacket supports a 300 V (CMG, FPL, PLTC-ER) rating and a UL temperature of 90°C for use in specified indoor, outdoor, and below-grade conduit environments.
Key Features
- Rated-CMG-FPL-PLTC security & sound cable with UL voltage rating: 300 V (CMG, FPL, PLTC-ER).
- 4 conductors, 18 AWG, with conductor stranding: 7x26 and conductor material: TC - Tinned Copper.
- PVC - Polyvinyl Chloride insulation with color code: Black, White, Red, Green.
- Tape shield with shield coverage: 100% and drainwire type: 20 AWG (7x28) TC.
- Waterblocking: Waterblock Tape for moisture-focused installations.
- PVC - Polyvinyl Chloride jacket with overall cable diameter (nominal): 0.259 in (6.58 mm).
Technical Specs
Electrical & Physical Specs
| Insulation thickness (nom.) | 0.010 in (0.25 mm) |
|---|---|
| Insulation diameter (nom.) | 0.066 in (1.7 mm) |
| Shield material | Bi-Laminate (Alum+Poly) |
| Jacket thickness (nom.) | 0.037 in (0.94 mm) |
| Nom. diameter | 0.259 in (6.58 mm) |
| Bulk cable weight | 45 lbs/1000ft (67 kg/km) |
Performance & Electrical Characteristics
| Nom. conductor DCR | 6.6 Ohm/1000ft (22 Ohm/km) |
|---|---|
| Nom. capacitance cond-to-cond | 40 pF/ft (130 pF/m) |
| Nom. outer shield DCR | 15.25 Ohm/1000ft (50.03 Ohm/km) |
Environmental & Mechanical Ratings
| UL temperature | 90°C |
|---|---|
| Operating temperature | -20°C to +90°C |
| Stationary min. bend radius | 2.6 in (66 mm) |
| Installation min. bend radius | 2.6 in (66 mm) |
| Max. pull tension | 102 lbs (46.3 kg) |
| Environmental suitability | Water Exposure/Below-Grade Conduit, Indoor, Outdoor, Sunlight Resistance, Burial |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEEE 1202 |
Compliance & Certifications
| CPR compliance | CPR Euroclass: Eca |
|---|---|
| NEC / UL compliance | Article 725, Article 760, Article 800, CMG, FPL, PLTC |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Applications
- Use for security system wiring where a rated-CMG-FPL-PLTC cable is required.
- For intercom/PA installations, the shielded construction supports noise rejection.
- Choose for audio/speaker runs where consistent electrical characteristics are needed.
- Apply in power-limited controls covered under the listed NEC / UL compliance articles.
- In noisy & wet location environments, water exposure and shielding are key considerations.
- For below-grade duct and below-grade conduit scenarios, burial and water exposure suitability are specified.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Insulation thickness (nom.) | 0.010 in (0.25 mm) |
| Insulation diameter (nom.) | 0.066 in (1.7 mm) |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Jacket thickness (nom.) | 0.037 in (0.94 mm) |
| Nom. diameter | 0.259 in (6.58 mm) |
| Bulk cable weight | 45 lbs/1000ft (67 kg/km) |
| Nom. conductor DCR | 6.6 Ohm/1000ft (22 Ohm/km) |
| Nom. capacitance cond-to-cond | 40 pF/ft (130 pF/m) |
| Nom. outer shield DCR | 15.25 Ohm/1000ft (50.03 Ohm/km) |
| UL temperature | 90°C |
| Operating temperature | -20°C to +90°C |
| Stationary min. bend radius | 2.6 in (66 mm) |
| Installation min. bend radius | 2.6 in (66 mm) |
| Max Pull Tension | 102 lbs (46.3 kg) |
| Environmental suitability | Water Exposure/Below-Grade Conduit, Indoor, Outdoor, Sunlight Resistance, Burial |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEEE 1202 |
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 725, Article 760, Article 800, CMG, FPL, PLTC |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.