Belden 5303FE 008, Multi Conductor Cable 5C 18 AWG FRPVC Gray

SKU:Belden 5303FE 008
● Auf Lager
Beschreibung
Belden 5303FE 008 is a 5-conductor, 18 AWG security and sound cable for Indoor - Riser (CMR) installations. It uses 5-18 AWG stranded bare copper conductors with PO - Polyolefin insulation and a tape shield with 100% coverage plus a 24 AWG (7x32) TC drainwire. The PVC - Polyvinyl Chloride jacket includes a ripcord, and the cable is rated 300 V (CMR) and 75°C.
Key Features
- 5-conductor, 18 AWG construction for security and sound cabling needs.
- BC - Bare Copper conductors with 7x26 stranding.
- PO - Polyolefin insulation with color code: Black, Red, White, Green, Brown.
- Tape shield using Bi-Laminate (Alum+Poly) with 100% coverage and a 24 AWG (7x32) TC drainwire.
- PVC - Polyvinyl Chloride jacket with ripcord for easier pulls and jacket removal.
- UL voltage rating: 300 V (CMR) and UL temperature: 75°C.
Technical Specs
Electrical & Physical Specs
| Conductor count | 5 |
|---|---|
| Conductor size | 18 AWG |
| Insulation thickness (nom.) | 0.009 in (0.23 mm) |
| Insulation diameter (nom.) | 0.062 in (1.6 mm) |
| Jacket thickness (nom.) | 0.017 in (0.43 mm) |
| Overall cable diameter (nominal) | 0.205 in (5.21 mm) |
| Bulk cable weight | 38 lbs/1000ft |
Performance & Electrical Characteristics
| Nom. conductor DCR | 6.5 Ohm/1000ft |
|---|---|
| Nom. capacitance cond-to-cond | 29 pF/ft (95 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 52.25 pF/ft (171.4 pF/m) |
| Max. current | 4 Amps per Conductor @ 25°C |
| Nom outer shield DCR | 14.4 Ohm/1000ft (47.2 Ohm/km) |
Environmental & Mechanical Ratings
| Operating temperature | -20°C to +75°C |
|---|---|
| Stationary min. bend radius | 2.1 in (53 mm) |
| Installation min. bend radius | 2.1 in (53 mm) |
| Max. pull tension | 126 lbs (57.2 kg) |
| Environmental suitability | Indoor - Riser, Indoor |
Compliance & Certifications
| Flammability / reaction to fire | UL 1666 Riser, FT4, IEC 60332-1-2 |
|---|---|
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 800, CMR |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Plenum number | 6303FE |
Applications
- Use in security system installations where a shielded multi-conductor cable is needed for signal runs.
- Support intercom/PA wiring for audio and control connections within indoor riser pathways.
- Run audio/speaker lines where the listed capacitance and shielding characteristics are required.
- Install for power-limited controls in building systems that call for CMR-rated indoor riser cable.
- Choose for noisy environment installations where shielding helps reduce interference.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Conductor count | 5 |
| Conductor size | 18 AWG |
| Insulation thickness (nom.) | 0.009 in (0.23 mm) |
| Insulation diameter (nom.) | 0.062 in (1.6 mm) |
| Jacket thickness (nom.) | 0.017 in (0.43 mm) |
| Overall cable diameter (nominal) | 0.205 in (5.21 mm) |
| Bulk cable weight | 38 lbs/1000ft |
| Nom. conductor DCR | 6.5 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 29 pF/ft (95 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 52.25 pF/ft (171.4 pF/m) |
| Max. current | 4 Amps per Conductor @ 25°C |
| Nom. outer shield DCR | 14.4 Ohm/1000ft (47.2 Ohm/km) |
| Operating temperature | -20°C to +75°C |
| Stationary min. bend radius | 2.1 in (53 mm) |
| Installation min. bend radius | 2.1 in (53 mm) |
| Max Pull Tension | 126 lbs (57.2 kg) |
| Environmental suitability | Indoor - Riser, Indoor |
| Flammability / reaction to fire | UL 1666 Riser, FT4, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 800, CMR |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Plenum number | 6303FE |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?