Belden 5340F1 010, Multi Conductor 1 FS PR 18 AWG PVC PVC Black

SKU:Belden 5340F1 010
● Auf Lager
Beschreibung
Belden 5340F1 010 is a security & sound cable with 1 pair of 18 AWG stranded tinned copper conductors, PVC insulation, and a PVC jacket. It features a tape shield with 100% coverage plus a 20 AWG (7x28) TC drainwire and Waterblock Tape for added protection in noisy and wet locations and below-grade duct runs. Rated-CMG-FPL-PLTC- and UL Voltage Rating: 300 V, it is specified for indoor/outdoor use with sunlight resistance.
Key Features
- 1 pair construction with 18 AWG stranded tinned copper conductors (7x26).
- PVC insulation with black & red color code.
- Tape shield (Bi-Laminate (Alum+Poly)) with 100% coverage and a 20 AWG (7x28) TC drainwire.
- Waterblocking: Waterblock Tape.
- PVC jacket with environmental suitability: indoor/outdoor, indoor, outdoor, sunlight resistance.
- Ratings: Rated-CMG-FPL-PLTC-.
Technical Specs
Construction & Materials
| Number of elements | 1 pair |
|---|---|
| Conductor size | 18 AWG |
| Conductor stranding | 7x26 |
| Conductor material | TC - Tinned Copper |
| Insulation material | PVC - Polyvinyl Chloride |
| Nom. thickness | 0.017 in (0.43 mm) |
| Nom. insulation diameter | 0.080 in (2.0 mm) |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Shield coverage | 100% |
| Drainwire type | 20 AWG (7x28) TC |
| Jacket material | PVC - Polyvinyl Chloride |
| Nom. jacket thickness | 0.037 in (0.94 mm) |
| Nom. diameter | 0.262 in (6.65 mm) |
| Overall cable diameter (nominal) | 0.262 in (6.65 mm) |
Electrical Characteristics
| Nom. conductor DCR | 7 Ohm/1000ft (23 Ohm/km) |
|---|---|
| Nom. capacitance cond-to-cond | 45 pF/ft (150 pF/m) |
| Max. current | 14 Amps per Conductor @ 25°C |
| Nom outer shield DCR | 8.5 Ohm/1000ft (28 Ohm/km) |
| UL voltage rating | 300 V |
Environmental & Mechanical Ratings
| UL temperature | 90°C |
|---|---|
| Operating temperature | -20°C to +90°C |
| Bend radius (stationary min.) | 2.6 in (66 mm) |
| Bend radius (installation min.) | 2.6 in (66 mm) |
| Max. pull tension | 57 lbs (26 kg) |
| Bulk cable weight | 27 lbs/1000ft (40 kg/km) |
Compliance & Certifications
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEEE 1202 FT4, IEC 60332-1-2 |
|---|---|
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 725, Article 760, Article 800 |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Applications
- Designed for security system wiring where shielded, waterblocked construction is specified.
- Well-suited for intercom/PA installations that require a listed security & sound cable.
- Commonly used in audio/speaker runs where a 1 pair shielded cable is called for.
- Applied in power-limited controls circuits covered under the listed NEC / UL articles.
- Specified for noisy & wet location installations where shielding and waterblocking are required.
- Appropriate for below-grade duct runs as indicated in the application list.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Number of elements | 1 pair |
| Conductor size | 18 AWG |
| Conductor stranding | 7x26 |
| Conductor Material | TC - Tinned Copper |
| Insulation Material | PVC - Polyvinyl Chloride |
| Nom. thickness | 0.017 in (0.43 mm) |
| Nom. insulation diameter | 0.080 in (2.0 mm) |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield Coverage | 100% |
| Drainwire type | 20 AWG (7x28) TC |
| Jacket Material | PVC - Polyvinyl Chloride |
| Nom. jacket thickness | 0.037 in (0.94 mm) |
| Nom. diameter | 0.262 in (6.65 mm) |
| Overall cable diameter (nominal) | 0.262 in (6.65 mm) |
| Nom. conductor DCR | 7 Ohm/1000ft (23 Ohm/km) |
| Nom. capacitance cond-to-cond | 45 pF/ft (150 pF/m) |
| Max. current | 14 Amps per Conductor @ 25°C |
| Nom. outer shield DCR | 8.5 Ohm/1000ft (28 Ohm/km) |
| UL Voltage Rating | 300 V |
| UL temperature | 90°C |
| Operating temperature | -20°C to +90°C |
| Bend radius (stationary min.) | 2.6 in (66 mm) |
| Bend radius (installation min.) | 2.6 in (66 mm) |
| Max Pull Tension | 57 lbs (26 kg) |
| Bulk cable weight | 27 lbs/1000ft (40 kg/km) |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEEE 1202 FT4, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 725, Article 760, Article 800 |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.