Belden 5341UE 008, Multi Conductor 2 Pair 18 AWG FRPVC Gray

SKU:Belden 5341UE 008
● Auf Lager
Beschreibung
Belden 5341UE 008 is a security & sound riser (CMR) cable with 2-18 AWG stranded bare copper pairs and a PVC jacket. It uses PP - Polypropylene insulation with color coding Black & Red, Black & White for identification during installation. Electrical performance includes a 300 V rating, 6.55 Ohm/1000ft DCR, and 29 pF/ft (95 pF/m) capacitance Cond-to-Cond. Designed for indoor riser pathways, it includes a ripcord and sequential footage marking every two feet.
Key Features
- 2-18 AWG stranded bare copper pairs for security & sound wiring needs.
- PVC - Polyvinyl Chloride jacket with a ripcord for easier pulls and stripping.
- PP - Polypropylene insulation with color code Black & Red, Black & White for clear conductor identification.
- Sequential footage marking every two feet to support measuring and installation.
- Indoor riser suitability with NEC / UL compliance: Article 800, CMR.
Technical Specs
Construction & Materials
| Number of pairs | 2 |
|---|---|
| Conductor size | 18 AWG |
| Conductor stranding | 7x26 |
| Conductor material | BC - Bare Copper |
| Insulation material | PP - Polypropylene |
| Nom. thickness (insulation) | 0.0085 in (0.22 mm) |
| Nom. insulation diameter | 0.062 in (1.6 mm) |
| Outer shield | No Shield |
| Jacket material | PVC - Polyvinyl Chloride |
| Nom. thickness (jacket) | 0.017 in (0.43 mm) |
| Overall cable diameter (nominal) | 0.246 in |
| Plenum number | 6341UE |
Electrical Characteristics
| UL voltage rating | 300 V |
|---|---|
| Nom. conductor DCR | 6.55 Ohm/1000ft |
| Nom. capacitance Cond-to-Cond | 29 pF/ft (95 pF/m) |
| Max. current | 11.2 Amps per Conductor at 30ºC |
Environmental & Mechanical Ratings
| UL temperature | 75°C |
|---|---|
| Operating temperature | -20°C to +75°C |
| Bend radius (stationary min.) | 2.46 in (62.5 mm) |
| Bend radius (installation min.) | 2.46 in |
| Max. pull tension | 90 lbs (41 kg) |
| Bulk cable weight | 30 lbs/1000ft |
Compliance & Certifications
| Fire rating | UL1666 Riser, FT4, IEEE 1202 FT4, IEC 60332-1-2 |
|---|---|
| CEC / C(UL) compliance | CMG |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Applications
- Supports security system wiring in indoor riser pathways where organized pair identification helps during installation.
- Ideal for intercom/PA installations that need a paired construction for signal and control connections.
- Suitable for audio/speaker runs in building pathways where a riser-rated cable is required.
- Commonly used in power-limited controls to route low-voltage control circuits through indoor riser spaces.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Number of pairs | 2 |
| Conductor size | 18 AWG |
| Conductor stranding | 7x26 |
| Conductor Material | BC - Bare Copper |
| Insulation Material | PP - Polypropylene |
| Nom. thickness (insulation) | 0.0085 in (0.22 mm) |
| Nom. insulation diameter | 0.062 in (1.6 mm) |
| Outer shield | No Shield |
| Jacket Material | PVC - Polyvinyl Chloride |
| Nom. thickness (jacket) | 0.017 in (0.43 mm) |
| Overall cable diameter (nominal) | 0.246 in |
| Plenum number | 6341UE |
| UL Voltage Rating | 300 V |
| Nom. conductor DCR | 6.55 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 29 pF/ft (95 pF/m) |
| Max. current | 11.2 Amps per Conductor at 30ºC |
| UL temperature | 75°C |
| Operating temperature | -20°C to +75°C |
| Bend radius (stationary min.) | 2.46 in (62.5 mm) |
| Bend radius (installation min.) | 2.46 in |
| Max Pull Tension | 90 lbs (41 kg) |
| Bulk cable weight | 30 lbs/1000ft |
| Fire rating | UL1666 Riser, FT4, IEEE 1202 FT4, IEC 60332-1-2 |
| CEC / C(UL) compliance | CMG |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.