Belden 602PTZ 000 CCTV Steuerleistung 1 RG59 2C18 geschirmt 2C18 specifications
AttributeValue
Cable typePTZ (CCTV + Control + Power) Cable
Environmental spaceIndoor - Plenum
NEC articlesArticle 800
NEC / UL complianceCMP
CPR EuroclassEca
RG type59
Number of Conductors5
Coax conductor20 AWG solid BC - Bare Copper, nominal diameter 0.032 in (No. of coax: 1)
Pair1 conductors18 AWG stranded 19x30 BC - Bare Copper, nominal diameter 0.044 in (No. of Conductors: 2)
Pair2 conductors18 AWG stranded 7x26 BC - Bare Copper, nominal diameter 0.047 in (No. of Conductors: 2)
Coax insulationFEP - Fluorinated Ethylene Propylene (Foam), nominal diameter 0.133 in
Pair1 insulationFEP - Fluorinated Ethylene Propylene, nominal diameter 0.059 in
Pair2 insulationPVC - Polyvinyl Chloride, Flamarrest®, nominal wall thickness 0.009 in
Inner jacketPVC - Polyvinyl Chloride, Flamarrest®, nominal diameter 0.193 in, nominal wall thickness 0.016 in; PVC - Polyvinyl Chloride, Flamarrest®, nominal diameter 0.150 in, nominal wall thickness 0.014 in; PVC - Polyvinyl Chloride, Flamarrest®, nominal diameter 0.158 in, nominal wall thickness 0.015 in
Outer jacketNo Jacket, nominal diameter 0.363 in
Color code (coax core)White
Color code (Pair1)Blue & White/Blue
Color code (Pair2)Black & Red
UL Voltage Rating300 V RMS
Delay (coax)max. delay skew 84 ns/100m; nominal delay 1.21 ns/ft; nominal velocity of propagation (VP) 84%
Capacitance (coax)16.1 pF/ft Conductor to Shield
Capacitance (Pair1)51 pF/ft Conductor to Conductor; 97 pF/ft Conductor to Shield
Capacitance (Pair2)30 pF/ft Conductor to Conductor
Max. recommended current (Pair1)5.2 Amps per Conductor at 25ºC
Max. recommended current (Pair2)5 Amps per Conductor at 25ºC
Conductor DCR (coax)nominal Conductor DCR 10 Ohm/1000ft; nominal inner Shield DCR 2.5 Ohm/1000ft
Conductor DCR (Pair1)nominal Conductor DCR 5.5 Ohm/1000ft; nominal inner Shield DCR 7.3 Ohm/1000ft; nominal outer Shield DCR 7.3 Ohm/1000ft
Conductor DCR (Pair2)nominal Conductor DCR 6.5 Ohm/1000ft
Insertion loss @ 1 MHz.29 dB/100ft
Insertion loss 5 MHz0.7 dB/100ft
Insertion loss @ 10 MHz1.1 dB/100ft
Insertion loss @ 50 MHz1.8 dB/100ft
Insertion loss @ 100 MHz2.7 dB/100ft
Insertion loss @ 200 MHz3.9 dB/100ft
Insertion loss @ 400 MHz5.9 dB/100ft
Insertion loss @ 700 MHz8.5 dB/100ft
Insertion loss @ 900 MHz10 dB/100ft
Insertion loss @ 1000 MHz10.7 dB/100ft
Installation temperature range0°C To +75°C
Operating Temperature Range-10°C To +75°C
Separation temp range0°C To +75°C
UL Temperature Rating75°C
Bulk cable weight65 lbs/1000ft
Maximum recommended pulling tension162 lbs
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/11/EC (BFR)Yes
EU Directive 2011/65/EU (RoHS 2)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2015/863/EU (RoHS 2 amendment)Yes
EU directive complianceYes
EU CE markYes
MII Order #39 (China RoHS)Yes
Non-Plenum number502PTZ
FootnoteC - CRATE REEL PUT-UP.
Patent infoThis product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents
Item TypeBelden Multi Conductor Cable
Other Part Numbers602PTZ 0001000, UPC 612825172062