Belden 6201FE 877, Multi Conductor 3C 16 AWG FLRST FS Natural

SKU:Belden 6201FE 877
● Auf Lager
Beschreibung
Belden 6201FE 877 is a security & commercial audio cable with 3 conductor 16 AWG stranded (19x29) BC - bare copper conductors and an overall Beldfoil® tape shield (foil side out) with drain wire. It uses Flamarrest® insulation and a Flamarrest® jacket with ripcord, and carries a Plenum-CMP rating with a UL voltage rating of 300 V (CMP). Electrical performance includes max. current of 6.25 Amps per Conductor @ 25°C. It also features sequential footage marking every two feet to support measuring and cut-to-length work.
Key Features
- 3 conductor 16 AWG stranded (19x29) BC - bare copper conductors for security and commercial audio wiring.
- Overall Beldfoil® tape shield (foil side out) with drain wire and 100% shield coverage.
- Flamarrest® insulation and a Flamarrest® jacket with ripcord.
- Plenum-CMP rated with UL voltage rating: 300 V (CMP).
- Sequential footage marking every two feet to support accurate pulls and cut-to-length work.
Technical Specs
Construction & Materials
| Conductor stranding | 19x29 |
|---|---|
| Insulation material | PVC - Polyvinyl Chloride |
| Insulation nominal thickness | 0.009 in (0.23 mm) |
| Insulation color code | Black, Red, White |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Shield coverage | 100% |
| Drainwire type | 24 AWG (7x32) TC |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Outer jacket nominal thickness | 0.015 in (0.38 mm) |
Physical Specs
| Overall cable diameter (nominal) | 0.195 in (4.95 mm) |
|---|---|
| Bulk cable weight | 36 lbs/1000ft (54 kg/km) |
| Non-Plenum number | 5201FE |
Performance & Electrical Characteristics
| Conductor DCR (nom.) | 4 Ohm/1000ft (13 Ohm/km) |
|---|---|
| Capacitance, Cond-to-Cond (nom.) | 81.5 pF/ft (267 pF/m) |
| Capacitance, Cond-to-other (nom.) | 146.7 pF/ft (481.3 pF/m) |
| Inductance (nom.) | 0.15 μH/ft (0.49 μH/m) |
| Max. current | 6.25 Amps per Conductor @ 25°C |
| Outer Shield DCR (nom.) | 15.2 Ohm/1000ft (49.9 Ohm/km) |
Environmental & Mechanical Ratings
| UL temperature | 75°C |
|---|---|
| Operating temperature | 0°C to +75°C |
| Bend radius (stationary min.) | 2.0 in (51 mm) |
| Bend radius (installation min.) | 2.0 in (51 mm) |
| Max. pull tension | 116 lbs (52.6 kg) |
| Environmental suitability | Indoor - Plenum, Indoor |
Compliance & Certifications
| Flammability / reaction to fire | NFPA 262, UL 910 (Plenum), FT6 |
|---|---|
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| Sustainability | CA Prop 65 |
Applications
- Designed for security systems using shielded multi-conductor cable for signal and control wiring.
- Supports intercom/PA systems in indoor installations.
- Commonly used in sound/audio systems where consistent electrical characteristics are needed.
- Suitable for power limited controls in plenum and other indoor environments.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Conductor stranding | 19x29 |
| Insulation Material | PVC - Polyvinyl Chloride |
| Insulation nominal thickness | 0.009 in (0.23 mm) |
| Insulation color code | Black, Red, White |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield Coverage | 100% |
| Drainwire type | 24 AWG (7x32) TC |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Outer jacket nominal thickness | 0.015 in (0.38 mm) |
| Overall cable diameter (nominal) | 0.195 in (4.95 mm) |
| Bulk cable weight | 36 lbs/1000ft (54 kg/km) |
| Non-Plenum number | 5201FE |
| Conductor DCR (nom.) | 4 Ohm/1000ft (13 Ohm/km) |
| Capacitance, Cond-to-Cond (nom.) | 81.5 pF/ft (267 pF/m) |
| Capacitance, Cond-to-other (nom.) | 146.7 pF/ft (481.3 pF/m) |
| Inductance (nom.) | 0.15 µH/ft (0.49 µH/m) |
| Max. current | 6.25 Amps per Conductor @ 25°C |
| Outer shield DCR (nom) | 15.2 Ohm/1000ft (49.9 Ohm/km) |
| UL temperature | 75°C |
| Operating temperature | 0°C to +75°C |
| Bend radius (stationary min.) | 2.0 in (51 mm) |
| Bend radius (installation min.) | 2.0 in (51 mm) |
| Max Pull Tension | 116 lbs (52.6 kg) |
| Environmental suitability | Indoor - Plenum, Indoor |
| Flammability / reaction to fire | NFPA 262, UL 910 (Plenum), FT6 |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| Sustainability | CA Prop 65 |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.