Belden 6202FE 877, FLRST FS 4C 16 AWG Multi Conductor Natural

SKU:Belden 6202FE 877
● Auf Lager
Beschreibung
Belden 6202FE 877 is a plenum-rated security & commercial audio cable with 4 stranded 16 AWG BC - Bare Copper conductors and a PVC - Polyvinyl Chloride jacket. It features PVC - Polyvinyl Chloride insulation, a Beldfoil® tape shield, and a 24 AWG (7x32) TC drainwire to help manage noise. UL rated 300 V, it has a 0.215 in (5.46 mm) nominal diameter for routing in plenum spaces. A ripcord and sequential footage marking every two feet support efficient installation and measurement.
Key Features
- Plenum-rated construction for indoor - plenum, indoor installations.
- 4 stranded 16 AWG conductors with 19x29 stranding and BC - Bare Copper conductor material.
- Beldfoil® tape shield with 100% coverage and a 24 AWG (7x32) TC drainwire for noise rejection.
- PVC - Polyvinyl Chloride jacket with ripcord and a 0.215 in (5.46 mm) nominal diameter for easier routing.
- UL voltage rating: 300 V.
- Sequential footage marking every two feet to help with measuring and layout during installation.
Technical Specs
Construction & Materials
| Insulation material | PVC - Polyvinyl Chloride |
|---|---|
| Nom. thickness | 0.009 in (0.23 mm) |
| Nom. insulation diameter | 0.075 in (1.9 mm) |
| Color code | Black, Red, White, Green |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Nom. jacket thickness | 0.015 in (0.38 mm) |
Electrical Characteristics
| Nom. outer shield DCR | 14.4 Ohm/1000ft (47.2 Ohm/km) |
|---|---|
| Nom. conductor DCR | 4 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 45 pF/ft (150 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 81 pF/ft (270 pF/m) |
| Nom. inductance | 0.15 μH/ft (0.49 μH/m) |
| Max. current | 14.4 Amps per Conductor @ 25°C |
Environmental & Mechanical Ratings
| Operating temperature | 0°C to +75°C |
|---|---|
| UL temperature | 75°C |
| Bend radius (stationary min.) | 2.2 in (56 mm) |
| Bend radius (installation min.) | 2.2 in (56 mm) |
| Max. pull tension | 165 lbs (74.8 kg) |
| Bulk cable weight | 46 lbs/1000ft |
Compliance & Certifications
| NEC / UL compliance | Article 800, CMP |
|---|---|
| CEC / C(UL) compliance | CMP |
| Flammability / reaction to fire | NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Related Part Number
| Non-plenum number | 5202FE |
|---|
Applications
- Security systems that require a plenum-rated cable for indoor routing.
- Intercom/PA systems that benefit from shielded construction to help manage noise.
- Sound/audio systems that require a security & commercial audio cable format.
- Power limited controls in indoor installations where CMP compliance is specified.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Insulation Material | PVC - Polyvinyl Chloride |
| Nom. thickness | 0.009 in (0.23 mm) |
| Nom. insulation diameter | 0.075 in (1.9 mm) |
| Color Code | Black, Red, White, Green |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Nom. jacket thickness | 0.015 in (0.38 mm) |
| Nom. outer shield DCR | 14.4 Ohm/1000ft (47.2 Ohm/km) |
| Nom. conductor DCR | 4 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 45 pF/ft (150 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 81 pF/ft (270 pF/m) |
| Nom. inductance | 0.15 µH/ft (0.49 µH/m) |
| Max. current | 14.4 Amps per Conductor @ 25°C |
| Operating temperature | 0°C to +75°C |
| UL temperature | 75°C |
| Bend radius (stationary min.) | 2.2 in (56 mm) |
| Bend radius (installation min.) | 2.2 in (56 mm) |
| Max Pull Tension | 165 lbs (74.8 kg) |
| Bulk cable weight | 46 lbs/1000ft |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| Flammability / reaction to fire | NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Non-Plenum number | 5202FE |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.