Belden 6300FE 008U, Multi Conductor Cable 2C 18 Stranded FOIL SHD FRPVC

SKU:Belden 6300FE 008U
● Auf Lager
Beschreibung
Belden 6300FE 008U is a Plenum-CMP Security & Commercial Audio Cable with 2 conductors of 18 AWG stranded BC - Bare Copper. It features PVC - Polyvinyl Chloride insulation and a PVC - Polyvinyl Chloride jacket with ripcord, along with a tape shield with 100% coverage and a 24 AWG (7x32) TC drainwire. Designed for indoor plenum installations, it is rated 300 V and meets NFPA 262 and Article 800, CMP.
Key Features
- Plenum-CMP fire rating for indoor plenum installations.
- 2 x 18 AWG stranded BC - Bare Copper conductors (7x26) for security and commercial audio wiring.
- PVC - Polyvinyl Chloride insulation and a PVC - Polyvinyl Chloride jacket with ripcord for easier pulls and handling.
- Tape shield with 100% coverage and Bi-Laminate (Alum+Poly) shield material, plus a 24 AWG (7x32) TC drainwire.
- 0.162 in (4.11 mm) nominal overall cable diameter for routing in tighter pathways.
Technical Specs
Construction & Materials
| Cable type | Security & Commercial Audio Cable |
|---|---|
| Number of conductors | 2 |
| Conductor size | 18 AWG |
| Conductor stranding | 7x26 |
| Conductor material | BC - Bare Copper |
| Insulation material | PVC - Polyvinyl Chloride |
| Nom. insulation thickness | 0.009 in (0.23 mm) |
| Nom. insulation diameter | 0.063 in (1.6 mm) |
| Color code | Black, Red |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Shield coverage | 100% |
| Drainwire type | 24 AWG (7x32) TC |
| Jacket material | PVC - Polyvinyl Chloride |
| Nom. jacket thickness | 0.015 in (0.38 mm) |
| Ripcord | Yes |
Performance & Electrical Characteristics
| UL voltage rating | 300 V |
|---|---|
| Nom. conductor DCR | 6.4 Ohm/1000ft |
| Nom. capacitance (cond-to-cond) | 70 pF/ft (230 pF/m) |
| Nom. capacitance (cond-to-other) | 126 pF/ft (413 pF/m) |
| Nom. inductance | 0.15 μH/ft (0.49 μH/m) |
| Max. current | 14 Amps per conductor @ 25°C |
| Nom outer shield DCR | 15.9 Ohm/1000ft (52.2 Ohm/km) |
Environmental & Mechanical Ratings
| UL temperature | 75°C |
|---|---|
| Operating temperature | 0°C to +75°C |
| Bend radius (stationary min.) | 1.6 in (41 mm) |
| Bend radius (installation min.) | 1.6 in (41 mm) |
| Max. pull tension | 50.3 lbs (22.8 kg) |
| Bulk cable weight | 21 lbs/1000ft |
| Environmental suitability | Indoor - Plenum, Indoor |
Compliance & Certifications
| Flammability / reaction to fire | NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2 |
|---|---|
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Related Part Reference
| Non-Plenum number | 5300FH |
|---|
Applications
- Use in security system installations where a plenum-rated cable is required.
- Run intercom/PA wiring through indoor building pathways.
- Support audio/speaker connections that benefit from an overall shield and drainwire.
- Install in noisy environments where shielding helps manage interference.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Cable type | Security & Commercial Audio Cable |
| Number of Conductors | 2 |
| Conductor size | 18 AWG |
| Conductor stranding | 7x26 |
| Conductor Material | BC - Bare Copper |
| Insulation Material | PVC - Polyvinyl Chloride |
| Nom. insulation thickness | 0.009 in (0.23 mm) |
| Nom. insulation diameter | 0.063 in (1.6 mm) |
| Color Code | Black, Red |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield Coverage | 100% |
| Drainwire type | 24 AWG (7x32) TC |
| Jacket Material | PVC - Polyvinyl Chloride |
| Nom. jacket thickness | 0.015 in (0.38 mm) |
| Ripcord | Yes |
| UL Voltage Rating | 300 V |
| Nom. conductor DCR | 6.4 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 70 pF/ft (230 pF/m) |
| Nom. capacitance (Cond-to-other) | 126 pF/ft (413 pF/m) |
| Nom. inductance | 0.15 µH/ft (0.49 µH/m) |
| Max. current | 14 Amps per conductor @ 25°C |
| Nom. outer shield DCR | 15.9 Ohm/1000ft (52.2 Ohm/km) |
| UL temperature | 75°C |
| Operating temperature | 0°C to +75°C |
| Bend radius (stationary min.) | 1.6 in (41 mm) |
| Bend radius (installation min.) | 1.6 in (41 mm) |
| Max Pull Tension | 50.3 lbs (22.8 kg) |
| Bulk cable weight | 21 lbs/1000ft |
| Environmental suitability | Indoor - Plenum, Indoor |
| Flammability / reaction to fire | NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2 |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Non-Plenum number | 5300FH |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.