Belden 6300FE 877, Commercial Audio Cable 2C 18 AWG FLRST FS Natural

SKU:Belden 6300FE 877
● Auf Lager
Beschreibung
Belden 6300FE 877 is a Plenum-CMP security & commercial audio cable with 2-18 AWG stranded bare copper conductors and PVC - Polyvinyl Chloride insulation. It includes an overall Beldfoil® tape shield (foil side out) with a drain wire to support noise rejection in signal runs. A PVC - Polyvinyl Chloride jacket with ripcord helps with pulling and stripping, and sequential footage marking every two feet supports installation accuracy. UL Voltage Rating is 300 V and UL temperature is 75°C.
Key Features
- Plenum-CMP cable construction for indoor - plenum and indoor environments.
- 2 conductors with 18 AWG size and 7x26 stranding.
- BC - Bare Copper conductors with PVC - Polyvinyl Chloride insulation.
- Overall Beldfoil® tape shield (foil side out) with 100% coverage and a drain wire.
- PVC - Polyvinyl Chloride jacket with ripcord for easier pulls and stripping.
- Sequential footage marking every two feet to help with measuring and layout.
Technical Specs
Construction & Materials
| Conductor material | BC - Bare Copper |
|---|---|
| Insulation thickness (nom.) | 0.009 in (0.23 mm) |
| Insulation diameter (nom.) | 0.063 in (1.6 mm) |
| Color code | Black, Red |
| Jacket thickness (nom.) | 0.015 in (0.38 mm) |
| Overall cable diameter (nom.) | 0.162 in (4.11 mm) |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Drainwire type | 24 AWG (7x32) TC |
Electrical Characteristics
| UL Voltage Rating | 300 V |
|---|---|
| Nom. Conductor DCR | 6.4 Ohm/1000ft |
| Nom. capacitance Cond-to-Cond | 70 pF/ft (230 pF/m) |
| Nom. capacitance Cond-to-other (conds + Shield) | 126 pF/ft (413 pF/m) |
| Nom. inductance | 0.15 μH/ft (0.49 μH/m) |
| Max. current | 14 Amps per Conductor @ 25°C |
| Nom outer Shield DCR | 15.9 Ohm/1000ft (52.2 Ohm/km) |
Environmental & Mechanical Ratings
| UL temperature | 75°C |
|---|---|
| Operating | 0°C to +75°C |
| Stationary min. bend radius | 1.6 in (41 mm) |
| Installation min. bend radius | 1.6 in (41 mm) |
| Max. pull tension | 50.3 lbs (22.8 kg) |
| Bulk cable weight | 21 lbs/1000ft |
Compliance & Certifications
| Flammability / reaction to fire | NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2 |
|---|---|
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Related Part Reference
| Non-Plenum number | 5300FH |
|---|
Applications
- Use in security system installations where shielded signal cabling is needed in indoor - plenum or indoor spaces.
- Support intercom/PA wiring runs that benefit from an overall shield and drain wire in building interiors.
- Choose for audio/speaker connections requiring a 2-conductor cable with consistent identification and footage marking.
- Install in noisy environment locations where the overall Beldfoil® tape shield and drain wire can help manage interference.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Conductor Material | BC - Bare Copper |
| Insulation thickness (nom.) | 0.009 in (0.23 mm) |
| Insulation diameter (nom.) | 0.063 in (1.6 mm) |
| Color Code | Black, Red |
| Jacket thickness (nom.) | 0.015 in (0.38 mm) |
| Overall cable diameter (nom.) | 0.162 in (4.11 mm) |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Drainwire type | 24 AWG (7x32) TC |
| UL Voltage Rating | 300 V |
| Nom. conductor DCR | 6.4 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 70 pF/ft (230 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 126 pF/ft (413 pF/m) |
| Nom. inductance | 0.15 µH/ft (0.49 µH/m) |
| Max. current | 14 Amps per Conductor @ 25°C |
| Nom. outer shield DCR | 15.9 Ohm/1000ft (52.2 Ohm/km) |
| UL temperature | 75°C |
| Operating | 0°C to +75°C |
| Stationary min. bend radius | 1.6 in (41 mm) |
| Installation min. bend radius | 1.6 in (41 mm) |
| Max Pull Tension | 50.3 lbs (22.8 kg) |
| Bulk cable weight | 21 lbs/1000ft |
| Flammability / reaction to fire | NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Non-Plenum number | 5300FH |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.