Belden 6302FE 877, FLRST FS 4C 18 AWG Multi Conductor Natural

SKU:Belden 6302FE 877
● Auf Lager
Beschreibung
Belden 6302FE 877 is a plenum-rated security & sound cable built with 4 stranded 18 AWG BC - Bare Copper conductors and a PVC - Polyvinyl Chloride jacket. It uses PVC - Polyvinyl Chloride insulation with an overall tape shield made from Bi-Laminate (Alum+Poly) plus a 24 AWG (7x32) TC drainwire. Key electrical and installation details include UL voltage rating: 300 V, UL temperature: 75°C, and sequential footage marking every two feet. Compliance includes Article 800, CMP, and plenum fire testing such as NFPA 262 and UL 910 (Plenum).
Key Features
- Includes 4 conductors with 18 AWG size for security, intercom/PA, and audio/speaker wiring needs.
- Features an overall tape shield with Bi-Laminate (Alum+Poly) material and 100% coverage, plus a 24 AWG (7x32) TC drainwire.
- Built with PVC - Polyvinyl Chloride insulation and a PVC - Polyvinyl Chloride jacket.
- Includes a ripcord to support easier handling during installation.
- Uses sequential footage marking every two feet for simpler measuring and pull tracking.
Technical Specs
Construction & Physical Specs
| Conductor stranding | 7x26 |
|---|---|
| Insulation thickness (nom.) | 0.009 in (0.23 mm) |
| Insulation diameter (nom.) | 0.061 in (1.5 mm) |
| Color code | Black, Red, White, Green |
| Jacket thickness (nom.) | 0.015 in (0.38 mm) |
| Overall cable diameter (nominal) | 0.188 in (4.78 mm) |
| Bulk cable weight | 32 lbs/1000ft |
| Non-plenum number | 5302FE |
Electrical Characteristics
| Nom. conductor DCR | 6.5 Ohm/1000ft |
|---|---|
| Capacitance, cond-to-cond (nom.) | 42 pF/ft (140 pF/m) |
| Capacitance, cond-to-other (nom.) | 76 pF/ft (250 pF/m) |
| Max. current | 11.2 Amps per Conductor at 25ºC (10°C Temperature Rise) |
| Nom outer shield DCR | 14.4 Ohm/1000ft (47.2 Ohm/km) |
Environmental & Mechanical Ratings
| Operating temperature | 0°C to +75°C |
|---|---|
| Bend radius (stationary min.) | 1.9 in (48 mm) |
| Bend radius (installation min.) | 1.9 in (48 mm) |
| Max. pull tension | 95 lbs (43 kg) |
| Environmental suitability | Indoor, Indoor |
Compliance & Certifications
| Flammability / reaction to fire | NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2 |
|---|---|
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Applications
- Use in security system installations where a plenum-rated cable is required.
- Run intercom/PA wiring in building spaces that call for CMP compliance.
- Support audio/speaker connections where shielded construction is used to help manage interference.
- Route through noisy environment areas where an overall shield and drainwire are used for noise rejection.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Conductor stranding | 7x26 |
| Insulation thickness (nom.) | 0.009 in (0.23 mm) |
| Insulation diameter (nom.) | 0.061 in (1.5 mm) |
| Color Code | Black, Red, White, Green |
| Jacket thickness (nom.) | 0.015 in (0.38 mm) |
| Overall cable diameter (nominal) | 0.188 in (4.78 mm) |
| Bulk cable weight | 32 lbs/1000ft |
| Non-Plenum number | 5302FE |
| Nom. conductor DCR | 6.5 Ohm/1000ft |
| Capacitance, Cond-to-Cond (nom.) | 42 pF/ft (140 pF/m) |
| Capacitance, Cond-to-other (nom.) | 76 pF/ft (250 pF/m) |
| Max. current | 11.2 Amps per Conductor at 25ºC (10°C Temperature Rise) |
| Nom. outer shield DCR | 14.4 Ohm/1000ft (47.2 Ohm/km) |
| Operating temperature | 0°C to +75°C |
| Bend radius (stationary min.) | 1.9 in (48 mm) |
| Bend radius (installation min.) | 1.9 in (48 mm) |
| Max Pull Tension | 95 lbs (43 kg) |
| Environmental suitability | Indoor, Indoor |
| Flammability / reaction to fire | NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2 |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |