Belden 6302FE 877U, FLRST FS 4C 18 AWG Multi Conductor Natural

SKU:Belden 6302FE 877U
● Auf Lager
Beschreibung
Belden 6302FE 877U is a Plenum-CMP security & sound cable for indoor installations in security systems, intercom/PA, and audio/speaker runs, including noisy environments. It features 4 stranded 18 AWG bare copper conductors with Flamarrest® insulation and an overall Beldfoil® tape shield with 100% coverage plus a 24 AWG (7x32) TC drainwire. The Flamarrest® PVC jacket includes a ripcord, and the cable is UL rated 300 V with a 75°C temperature rating.
Key Features
- Plenum-CMP security & sound cable for indoor installations.
- 4 stranded 18 AWG bare copper conductors with Flamarrest® insulation.
- Overall Beldfoil® tape shield with 100% coverage and a 24 AWG (7x32) TC drainwire for noise rejection.
- Flamarrest® PVC jacket with ripcord for easier pulls and stripping.
- Sequential footage marking every two feet to simplify measuring and installation.
Technical Specs
Construction & Materials
| Number of conductors | 4 |
|---|---|
| Conductor size | 18 AWG |
| Conductor stranding | 7x26 |
| Conductor material | BC - Bare Copper |
| Insulation material | PVC - Polyvinyl Chloride |
| Insulation thickness (nom.) | 0.009 in (0.23 mm) |
| Insulation diameter (nom.) | 0.061 in (1.5 mm) |
| Color code | Black, Red, White, Green |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Shield coverage | 100% |
| Drainwire type | 24 AWG (7x32) TC |
| Jacket material | PVC - Polyvinyl Chloride |
| Jacket thickness (nom.) | 0.015 in (0.38 mm) |
Electrical Characteristics
| UL voltage rating | 300 V |
|---|---|
| Conductor DCR (nom.) | 6.5 Ohm/1000ft |
| Outer shield DCR (nom.) | 14.4 Ohm/1000ft (47.2 Ohm/km) |
| Capacitance, cond-to-cond (nom.) | 42 pF/ft (140 pF/m) |
| Capacitance, cond-to-other (nom.) | 76 pF/ft (250 pF/m) |
| Max. current | 11.2 Amps per Conductor at 25ºC (10°C Temperature Rise) |
Physical Dimensions & Weight
| Overall cable diameter (nom.) | 0.188 in (4.78 mm) |
|---|---|
| Bulk cable weight | 32 lbs/1000ft |
Environmental & Mechanical Ratings
| UL temperature | 75°C |
|---|---|
| Operating temperature | 0°C to +75°C |
| Bend radius (stationary min.) | 1.9 in (48 mm) |
| Bend radius (installation min.) | 1.9 in (48 mm) |
| Max. pull tension | 95 lbs (43 kg) |
| Environmental suitability | Indoor, Indoor |
Compliance & Certifications
| Flammability / reaction to fire | NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2 |
|---|---|
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Non-Plenum number | 5302FE |
Applications
- Use in security system installations where an indoor, plenum-rated cable is required.
- Run intercom/PA wiring in buildings and facilities.
- Support audio/speaker runs for indoor distribution and connections.
- Install in noisy environment locations where shielding helps reduce interference.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Number of Conductors | 4 |
| Conductor size | 18 AWG |
| Conductor stranding | 7x26 |
| Conductor Material | BC - Bare Copper |
| Insulation Material | PVC - Polyvinyl Chloride |
| Insulation thickness (nom.) | 0.009 in (0.23 mm) |
| Insulation diameter (nom.) | 0.061 in (1.5 mm) |
| Color Code | Black, Red, White, Green |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield Coverage | 100% |
| Drainwire type | 24 AWG (7x32) TC |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket thickness (nom.) | 0.015 in (0.38 mm) |
| UL Voltage Rating | 300 V |
| Conductor DCR (nom.) | 6.5 Ohm/1000ft |
| Outer shield DCR (nom) | 14.4 Ohm/1000ft (47.2 Ohm/km) |
| Capacitance, Cond-to-Cond (nom.) | 42 pF/ft (140 pF/m) |
| Capacitance, Cond-to-other (nom.) | 76 pF/ft (250 pF/m) |
| Max. current | 11.2 Amps per Conductor at 25ºC (10°C Temperature Rise) |
| Overall cable diameter (nom.) | 0.188 in (4.78 mm) |
| Bulk cable weight | 32 lbs/1000ft |
| UL temperature | 75°C |
| Operating temperature | 0°C to +75°C |
| Bend radius (stationary min.) | 1.9 in (48 mm) |
| Bend radius (installation min.) | 1.9 in (48 mm) |
| Max Pull Tension | 95 lbs (43 kg) |
| Environmental suitability | Indoor, Indoor |
| Flammability / reaction to fire | NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2 |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Non-Plenum number | 5302FE |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.