Belden 638AMJ 004, CMP 4C#16+4C#18+3P#18FS+2C#18 YEL

SKU:Belden 638AMJ 004
● Auf Lager
Beschreibung
Belden 638AMJ 004 is a plenum-rated access control cable for access control, security system, and power limited controls installations. It features stranded bare copper conductors with Flamarrest® insulation and an overall Flamarrest® jacket. Only the card reader pairs are protected by an overall Beldfoil® shield and Flamarrest® jackets. The construction includes 3 pair(s), 18 AWG plus 4 conductor(s), 16 AWG; 4 conductor(s), 18 AWG; and 2 conductor(s), 18 AWG, and it is rated 300 V (UL CMP) with a 0°C to +75°C operating temperature range.
Key Features
- This plenum-CMP access control cable is rated 300 V (UL CMP) for indoor plenum installations.
- It uses stranded bare copper conductors with Flamarrest® insulation and an overall Flamarrest® jacket.
- Only the card reader pairs include an overall Beldfoil® shield with 100% coverage and a 24 AWG (7x32) TC drainwire.
- The conductor build supports mixed access control wiring: 3 pair(s), 18 AWG plus 4 conductor(s), 16 AWG; 4 conductor(s), 18 AWG; and 2 conductor(s), 18 AWG.
- It is tested to NFPA 262 and listed to NEC / UL compliance: Article 800, CMP.
Technical Specs
Cable Type & Environmental Suitability
| Cable type | Access Control Cable |
|---|---|
| Environmental suitability | Indoor - Plenum, Indoor |
| Operating temperature | 0°C to +75°C |
Conductor Construction & Configuration
| Conductor construction | All conductors stranded bare copper with Flamarrest® insulation |
|---|---|
| Card Reader conductors | 3 Pair(s), 18 AWG, 7x26, BC - Bare Copper |
| Door Contact conductors | 2 Conductor(s), 18 AWG, 7x26, BC - Bare Copper |
| REX/Spare conductors | 4 Conductor(s), 18 AWG, 7x26, BC - Bare Copper |
| Lock Power conductors | 4 Conductor(s), 16 AWG, 19x29, BC - Bare Copper |
Insulation, Shielding & Jacket Details
| Card Reader insulation | PVC - Polyvinyl Chloride; color code: Black & Red, White & Green, Brown & Orange |
|---|---|
| Door Contact insulation | PVC - Polyvinyl Chloride; color code: Black, Red |
| REX/Spare insulation | PVC - Polyvinyl Chloride; color code: Black, Red, White, Green |
| Lock Power insulation | PVC - Polyvinyl Chloride; nom. insulation diameter: 0.075 in (1.9 mm) |
| Card Reader shield | Tape; Bi-Laminate (Alum+Poly); 100% coverage; drainwire: 24 AWG (7x32) TC |
| Card Reader inner jacket | PVC - Polyvinyl Chloride; 0.288 in (7.32 mm); ripcord: Yes; color: Orange |
| Door Contact inner jacket | PVC - Polyvinyl Chloride; 0.154 in (3.91 mm); ripcord: Yes; color: White |
| REX/Spare inner jacket | PVC - Polyvinyl Chloride; 0.180 in (4.57 mm); ripcord: Yes; color: Blue |
| Lock Power inner jacket | PVC - Polyvinyl Chloride; 0.206 in (5.23 mm); ripcord: Yes; color: Gray |
| Outer jacket | PVC - Polyvinyl Chloride; nom. diameter: 0.548 in (13.9 mm); ripcord: Yes |
Physical & Mechanical Specs
| Overall cable diameter (nominal) | 0.548 in (13.9 mm) |
|---|---|
| Max. pull tension | 235 lbs (107 kg) |
| Bulk cable weight | 166 lbs/1000ft (247 kg/km) |
Performance & Electrical Characteristics
| Card Reader nom. conductor DCR | 6.6 Ohm/1000ft (22 Ohm/km) |
|---|---|
| Card Reader nom. inner shield DCR | 13.1 Ohm/1000ft (43.0 Ohm/km) |
| Card Reader nom. capacitance Cond-to-Cond | 40 pF/ft (130 pF/m) |
| Card Reader nom. capacitance Cond-to-Shield | 72 pF/ft (240 pF/m) |
| Card Reader max. current | 4 Amps per Conductor at 25ºC |
| Door Contact nom. conductor DCR | 6.6 Ohm/1000ft (22 Ohm/km) |
| Door Contact max. current | 4 Amps per Conductor at 25ºC |
| REX/Spare nom. conductor DCR | 6.6 Ohm/1000ft (22 Ohm/km) |
| REX/Spare max. current | 4 Amps per Conductor at 25ºC |
| Lock Power nom. conductor DCR | 4 Ohm/1000ft (13 Ohm/km) |
| Lock Power max. current | 5 Amps per Conductor at 25ºC |
Compliance & Certifications
| Flammability / reaction to fire | NFPA 262 |
|---|---|
| CEC / C(UL) compliance | CMP |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Related Part Reference
| Non-Plenum number | 538AMJ |
|---|
Applications
- Use it for access control installations where multiple conductors are needed to connect common door hardware and reader wiring needs.
- It supports security system wiring in indoor environments, including indoor plenum spaces.
- Choose it for power limited controls installations where a 300 V (UL CMP) plenum-rated cable is required.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Cable type | Access Control Cable |
| Environmental suitability | Indoor - Plenum, Indoor |
| Operating temperature | 0°C to +75°C |
| Conductor construction | All conductors stranded bare copper with Flamarrest® insulation |
| Card Reader conductors | 3 Pair(s), 18 AWG, 7x26, BC - Bare Copper |
| Door Contact conductors | 2 Conductor(s), 18 AWG, 7x26, BC - Bare Copper |
| REX/Spare conductors | 4 Conductor(s), 18 AWG, 7x26, BC - Bare Copper |
| Lock Power conductors | 4 Conductor(s), 16 AWG, 19x29, BC - Bare Copper |
| Card Reader insulation | PVC - Polyvinyl Chloride; color code: Black & Red, White & Green, Brown & Orange |
| Door Contact insulation | PVC - Polyvinyl Chloride; color code: Black, Red |
| REX/Spare insulation | PVC - Polyvinyl Chloride; color code: Black, Red, White, Green |
| Lock Power insulation | PVC - Polyvinyl Chloride; nom. insulation diameter: 0.075 in (1.9 mm) |
| Card Reader shield | Tape; Bi-Laminate (Alum+Poly); 100% coverage; drainwire: 24 AWG (7x32) TC |
| Card Reader inner jacket | PVC - Polyvinyl Chloride; 0.288 in (7.32 mm); ripcord: Yes; color: Orange |
| Door Contact inner jacket | PVC - Polyvinyl Chloride; 0.154 in (3.91 mm); ripcord: Yes; color: White |
| REX/Spare inner jacket | PVC - Polyvinyl Chloride; 0.180 in (4.57 mm); ripcord: Yes; color: Blue |
| Lock Power inner jacket | PVC - Polyvinyl Chloride; 0.206 in (5.23 mm); ripcord: Yes; color: Gray |
| Outer jacket | PVC - Polyvinyl Chloride; nom. diameter: 0.548 in (13.9 mm); ripcord: Yes |
| Overall cable diameter (nominal) | 0.548 in (13.9 mm) |
| Max Pull Tension | 235 lbs (107 kg) |
| Bulk cable weight | 166 lbs/1000ft (247 kg/km) |
| Card Reader nom. conductor DCR | 6.6 Ohm/1000ft (22 Ohm/km) |
| Card Reader nom. inner shield DCR | 13.1 Ohm/1000ft (43.0 Ohm/km) |
| Card Reader nom. capacitance Cond-to-Cond | 40 pF/ft (130 pF/m) |
| Card Reader nom. capacitance Cond-to-Shield | 72 pF/ft (240 pF/m) |
| Card Reader max. current | 4 Amps per Conductor at 25ºC |
| Door Contact nom. conductor DCR | 6.6 Ohm/1000ft (22 Ohm/km) |
| Door Contact max. current | 4 Amps per Conductor at 25ºC |
| REX/Spare nom. conductor DCR | 6.6 Ohm/1000ft (22 Ohm/km) |
| REX/Spare max. current | 4 Amps per Conductor at 25ºC |
| Lock Power nom. conductor DCR | 4 Ohm/1000ft (13 Ohm/km) |
| Lock Power max. current | 5 Amps per Conductor at 25ºC |
| Flammability / reaction to fire | NFPA 262 |
| CEC / C(UL) compliance | CMP |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Non-Plenum number | 538AMJ |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.