Kontakt1-800-975-3686
Ramcorp Wire & Cable

Belden 7805 010, RF100 RG 174 Coax 50 OHM PVC Black

Belden 7805 010, RF100 RG 174 Coax 50 OHM PVC Black

SKU:Belden 7805 010

$1.43/ FT

Auf Lager

Beschreibung

Spezifikationen

Belden 7805 010, RF100 RG 174 Coax 50 OHM PVC Black specifications
AttributeValue
Coax TypeRG174
RF seriesRF 100
Characteristic Impedance50 Ohm
Conductor25 AWG Solid, 0.018 in, BC - Bare Copper
InsulationPE - Polyethylene, 0.061 in (1.5 mm), White
Shield layer 1Tape, Bi-Laminate (Alum+Poly), Beldfoil®, 100%
Shield layer 2Braid, Tinned Copper (TC), 90%
JacketPVC - Polyvinyl Chloride
Overall cable diameter (nominal)0.110 in (2.79 mm)
Bulk cable weight9 lbs/1000ft
Frequency range (VSWR)5 - 6000 MHz
Max. VSWR1.25:1
Voltage Rating300 V
Nom. conductor DCR32 Ohm/1000ft
Nom. outer shield DCR9.1 Ohm/1000ft (30 Ohm/km)
Nom. capacitance (Cond-to-Shield)31.2 pF/ft (102 pF/m)
Nom. velocity of prop.66%
Attenuation5 MHz: 1.5 dB/100ft; 10 MHz: 2.2 dB/100ft; 30 MHz: 3.8 dB/100ft (max 3.9 dB/100ft); 50 MHz: 4.9 dB/100ft (max 5.1 dB/100ft); 150 MHz: 8.6 dB/100ft (max 8.8 dB/100ft); 220 MHz: 10.4 dB/100ft (max 10.7 dB/100ft); 450 MHz: 15.2 dB/100ft (max 15.5 dB/100ft); 900 MHz: 22.0 dB/100ft (max 22.5 dB/100ft); 1500 MHz: 28.7 dB/100ft (max 30.2 dB/100ft); 1800 MHz: 31.7 dB/100ft (max 33.5 dB/100ft); 2000 MHz: 33.4 dB/100ft (max 35.6 dB/100ft); 2500 MHz: 37.8 dB/100ft (max 40.8 dB/100ft); 3000 MHz: 42.0 dB/100ft (max 45.8 dB/100ft); 3500 MHz: 45.4 dB/100ft (max 49.5 dB/100ft); 4500 MHz: 52.3 dB/100ft (max 56.8 dB/100ft); 5800 MHz: 60.9 dB/100ft (max 64.3 dB/100ft); 6000 MHz: 62.0 dB/100ft (max 65.4 dB/100ft)
Power rating30 MHz: 216 W; 50 MHz: 154 W; 150 MHz: 74 W; 220 MHz: 57 W; 450 MHz: 34 W; 900 MHz: 21 W; 1,500 MHz: 14 W; 2,000 MHz: 12 W; 2,500 MHz: 10 W; 3,500 MHz: 8 W; 4,500 MHz: 7 W; 6,000 MHz: 5 W
Operating temperature-40°C to +75°C
Minimum bend radius (installation)0.25 in (6.4 mm)
Max Pull Tension16 lbs (7.3 kg)
Environmental suitabilityIndoor/Outdoor, Indoor, Aerial - Black only, When supported by messenger Wire
SustainabilityCA Prop 65
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC complianceChina RoHS II (GB/T 26572-2011)
Priced PerFT

Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.

Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?

Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.