Kontakt1-800-975-3686
Ramcorp Wire & Cable

Belden 7896A T5U DeviceBus für ODVA 2 16 AWG PVC

Belden 7896A T5U

SKU:Belden 7896A T5U

$1,186.80

Auf Lager

Beschreibung

Spezifikationen

Belden 7896A T5U DeviceBus für ODVA 2 16 AWG PVC specifications
AttributeValue
Conductor configuration2 Pair 16+18AWG (19x29+19x30)
Power pair1, 16 AWG, 19x29, TC - Tinned Copper
Data pair1, 18 AWG, 19x30, TC - Tinned Copper
Power insulationPVC/Nylon - Polyvinyl Chloride + Nylon, 0.022 in (0.56 mm) nominal thickness, 0.101 in (2.57 mm) nominal insulation diameter, Red & Black
Data insulationPP - Polypropylene, 0.033 in (0.84 mm) nominal thickness, 0.182 in (4.62 mm) nominal insulation diameter, Blue & White, Flame Retardant
Drainwire type16 AWG (19x29) TC
Outer jacket materialPVC - Polyvinyl Chloride
Outer jacket nominal thickness0.060 in (1.5 mm)
Outer jacket nominal diameter0.525 in (13.3 mm)
Overall cable diameter (nominal)0.525 in (13.3 mm)
Jacket OD +/-0.010
Bulk cable weight158 lbs/1000ft
Power pair nominal conductor DCR4.9 Ohm/1000ft
Power pair max. current8 Amps per Conductor at 25ºC
Data pair nominal conductor DCR6.9 Ohm/1000ft (23 Ohm/km)
Data pair nominal capacitance (Cond-to-Cond)14.7 pF/ft (48.2 pF/m)
Data pair nominal characteristic impedence120 Ohm
Data pair nominal delay1.6 ns/ft
Data pair nominal velocity of prop.75%
Outer shield DCR (nom)1.8 Ohm/1000ft (5.9 Ohm/km)
UL temperature75°C Dry
Operating temperature-40°C to +75°C
Installation temperature-25°C To +75°C
Bend radius (stationary min.)5 in (130 mm)
Bend radius (installation min.)5 in (130 mm)
Max Pull Tension190 lbs (86 kg)
Flammability / reaction to fireUL 1685 UL Loading, FT1
CPR complianceCPR Euroclass: Eca
NEC / UL complianceArticle 336, TC-ER
AWM complianceAWM I/II A/B
Other standard compliance(s)ODVA Cable V
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK regulation complianceUKCA Mark
APAC complianceChina RoHS II (GB/T 26572-2011)
Item TypeBelden Multi-Pair Cable
Other Part Numbers7896A T5U100, 7896A T5U250, 7896A T5U500, 7896A T5U1000
Priced PerFT

Dokumente

Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.

Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?

Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.