Belden 7916A 010, 18 AWG LDPE FRPVC Black

SKU:Belden 7916A 010
● Auf Lager
Beschreibung
Belden 7916A 010 is a Series 6 RG 6 coaxial cable with an 18 AWG solid 0.04 in BC - Bare Copper conductor and a black PVC jacket. It is designed for 75 Ohm signal performance in HDTV, DBS, broadband CATV, and Cable Modem installations. The cable features gas-injected FPE-Foamed (Cellular) Polyethylene insulation and a quad shield (F/B+F/B) design with Duobond® II and Duofoil® tri-laminate tapes plus aluminum braids (60% and 40% coverage). It is intended for indoor (not riser or plenum) environments.
Key Features
- Series 6 RG 6 coaxial construction with 1 coax and 1 conductor.
- 18 AWG solid BC - Bare Copper conductor with 0.04 in nominal diameter.
- Gas-injected FPE-Foamed (Cellular) Polyethylene insulation (0.18 in nominal diameter).
- Quad shield (F/B+F/B): Duobond® II tri-laminate tape (100%), aluminum braid (60%), Duofoil® tri-laminate tape (100%), aluminum braid (40%).
- Black PVC-Polyvinyl Chloride jacket with 0.298 in nominal diameter.
- Environmental space: indoor (not riser or plenum); outdoor: no not outdoor grade material.
Technical Specs
Electrical Characteristics
| Nominal characteristic impedance | 75 Ohm |
|---|---|
| Nominal capacitance (Conductor to Shield) | 16.2 pF/ft |
| Nominal inductance | 0.097 μH/ft |
| Nominal delay | 1.2 ns/ft |
| Nominal velocity of propagation (VP) [%] | 83% |
| Nominal conductor DCR | 6.4 Ohm/1000ft |
| Nominal outer shield DCR | 4.8 Ohm/1000ft |
| Outer conductor DCR | 4.8 Ohm/1000ft |
| UL voltage rating | 300 V RMS |
Performance (Return Loss, Insertion Loss, Shielding)
| Return loss 5-1000 MHz | 20 dB (Min. Structural Return Loss (SRL)) |
|---|---|
| Return loss 1000-2250 MHz | 15 dB (Min. Structural Return Loss (SRL)) |
| Return loss 2250-3000 MHz | 10 dB (Min. Structural Return Loss (SRL)) |
| High frequency (Nominal/Typical) 5 MHz | 0.5 dB/100ft (Nom. Insertion Loss), 30 dB (Nom. Structural Return Loss (SRL)) |
| High frequency (Nominal/Typical) 55 MHz | 1.4 dB/100ft (Nom. Insertion Loss), 24 dB (Nom. Structural Return Loss (SRL)) |
| High frequency (Nominal/Typical) 211 MHz | 2.6 dB/100ft (Nom. Insertion Loss) |
| High frequency (Nominal/Typical) 500 MHz | 4.1 dB/100ft (Nom. Insertion Loss) |
| High frequency (Nominal/Typical) 750 MHz | 5.1 dB/100ft (Nom. Insertion Loss) |
| High frequency (Nominal/Typical) 862 MHz | 5.5 dB/100ft (Nom. Insertion Loss) |
| High frequency (Nominal/Typical) 1000 MHz | 6 dB/100ft (Nom. Insertion Loss) |
| High frequency (Nominal/Typical) 1450 MHz | 7.8 dB/100ft (Nom. Insertion Loss) |
| High frequency (Nominal/Typical) 1800 MHz | 8.6 dB/100ft (Nom. Insertion Loss) |
| High frequency (Nominal/Typical) 2250 MHz | 9.8 dB/100ft (Nom. Insertion Loss) |
| High frequency (Nominal/Typical) 3000 MHz | 11.3 dB/100ft (Nom. Insertion Loss) |
| High frequency (Max.) 5 MHz | 0.58 dB/100ft (Max. Insertion Loss (Attenuation)) |
| High frequency (Max.) 55 MHz | 1.6 dB/100ft (Max. Insertion Loss (Attenuation)) |
| High frequency (Max.) 211 MHz | 3.05 dB/100ft (Max. Insertion Loss (Attenuation)) |
| High frequency (Max.) 500 MHz | 4.66 dB/100ft (Max. Insertion Loss (Attenuation)) |
| High frequency (Max.) 750 MHz | 5.65 dB/100ft (Max. Insertion Loss (Attenuation)) |
| High frequency (Max.) 862 MHz | 6.1 dB/100ft (Max. Insertion Loss (Attenuation)) |
| High frequency (Max.) 1000 MHz | 6.55 dB/100ft (Max. Insertion Loss (Attenuation)) |
| High frequency (Max.) 1450 MHz | 8 dB/100ft (Max. Insertion Loss (Attenuation)) |
| High frequency (Max.) 1800 MHz | 8.8 dB/100ft (Max. Insertion Loss (Attenuation)) |
| High frequency (Max.) 2250 MHz | 10 dB/100ft (Max. Insertion Loss (Attenuation)) |
| High frequency (Max.) 3000 MHz | 11.9 dB/100ft (Max. Insertion Loss (Attenuation)) |
| Screening 50 MHz | 110 dB (Shield Effectiveness) |
Physical & Mechanical
| Flooded | No not flooded over braid |
|---|---|
| Bulk cable weight | 33 lbs/1000ft |
| Maximum recommended pulling tension | 104 lbs |
| Minimum minor axis bend radius | 3 in |
Environmental, Fire & Compliance
| Operating temperature range | -40°C To +75°C |
|---|---|
| NEC/(UL) compliance | CATV, CM |
| CEC/C(UL) compliance | CM |
| CPR Euroclass | Eca |
| Fire rating | General Purpose (CM, CMG, CMX) |
| UL flammability | UL1685 UL Loading |
| EU directive 2000/53/EC (ELV) | Yes |
| EU directive 2003/96/EC (BFR) | Yes |
| EU directive 2011/65/EU (RoHS 2) | Yes |
| EU directive 2012/19/EU (WEEE) | Yes |
| EU directive 2015/863/EU (RoHS 2 amendment) | Yes |
| EU directive compliance | EU Directive 2003/11/EC (BFR) |
| EU CE mark | Yes |
| MII Order #39 (China RoHS) | Yes |
| Plenum (Y/N) | No |
| Plenum number | 7916AP |
| Footnote | C - CRATE REEL PUT-UP. |
Applications
- Use in HDTV installations requiring 75 Ohm coaxial signal performance.
- Support DBS systems for distributing satellite signals.
- Run broadband CATV in general-purpose indoor environments.
- Connect Cable Modem equipment for broadband service.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Nominal characteristic impedance | 75 Ohm |
| Nominal capacitance (conductor-to-shield) | 16.2 pF/ft |
| Nominal inductance | 0.097 µH/ft |
| Nominal delay | 1.2 ns/ft |
| Nominal velocity of propagation (VP) [%] | 83% |
| Nominal conductor DCR | 6.4 Ohm/1000ft |
| Nominal outer shield DCR | 4.8 Ohm/1000ft |
| Outer conductor DCR | 4.8 Ohm/1000ft |
| UL Voltage Rating | 300 V RMS |
| Return loss 5-1000 MHz | 20 dB (Min. Structural Return Loss (SRL)) |
| Return loss 1000-2250 MHz | 15 dB (Min. Structural Return Loss (SRL)) |
| Return loss 2250-3000 MHz | 10 dB (Min. Structural Return Loss (SRL)) |
| High frequency (nominal/typical) 5 MHz | 0.5 dB/100ft (Nom. Insertion Loss), 30 dB (Nom. Structural Return Loss (SRL)) |
| High frequency (Nominal/Typical) 55 MHz | 1.4 dB/100ft (Nom. Insertion Loss), 24 dB (Nom. Structural Return Loss (SRL)) |
| High frequency (Nominal/Typical) 211 MHz | 2.6 dB/100ft (Nom. Insertion Loss) |
| High frequency (Nominal/Typical) 500 MHz | 4.1 dB/100ft (Nom. Insertion Loss) |
| High frequency (Nominal/Typical) 750 MHz | 5.1 dB/100ft (Nom. Insertion Loss) |
| High frequency (Nominal/Typical) 862 MHz | 5.5 dB/100ft (Nom. Insertion Loss) |
| High frequency (Nominal/Typical) 1000 MHz | 6 dB/100ft (Nom. Insertion Loss) |
| High frequency (Nominal/Typical) 1450 MHz | 7.8 dB/100ft (Nom. Insertion Loss) |
| High frequency (Nominal/Typical) 1800 MHz | 8.6 dB/100ft (Nom. Insertion Loss) |
| High frequency (Nominal/Typical) 2250 MHz | 9.8 dB/100ft (Nom. Insertion Loss) |
| High frequency (Nominal/Typical) 3000 MHz | 11.3 dB/100ft (Nom. Insertion Loss) |
| High frequency (Max.) 5 MHz | 0.58 dB/100ft (Max. Insertion Loss (Attenuation)) |
| High frequency (Max.) 55 MHz | 1.6 dB/100ft (Max. Insertion Loss (Attenuation)) |
| High frequency (Max.) 211 MHz | 3.05 dB/100ft (Max. Insertion Loss (Attenuation)) |
| High frequency (Max.) 500 MHz | 4.66 dB/100ft (Max. Insertion Loss (Attenuation)) |
| High frequency (Max.) 750 MHz | 5.65 dB/100ft (Max. Insertion Loss (Attenuation)) |
| High frequency (Max.) 862 MHz | 6.1 dB/100ft (Max. Insertion Loss (Attenuation)) |
| High frequency (Max.) 1000 MHz | 6.55 dB/100ft (Max. Insertion Loss (Attenuation)) |
| High frequency (Max.) 1450 MHz | 8 dB/100ft (Max. Insertion Loss (Attenuation)) |
| High frequency (Max.) 1800 MHz | 8.8 dB/100ft (Max. Insertion Loss (Attenuation)) |
| High frequency (Max.) 2250 MHz | 10 dB/100ft (Max. Insertion Loss (Attenuation)) |
| High frequency (Max.) 3000 MHz | 11.9 dB/100ft (Max. Insertion Loss (Attenuation)) |
| Screening 50 MHz | 110 dB (Shield Effectiveness) |
| Flooded | No not flooded over braid |
| Bulk cable weight | 33 lbs/1000ft |
| Maximum recommended pulling tension | 104 lbs |
| Minimum minor axis bend radius | 3 in |
| Operating Temperature Range | -40°C To +75°C |
| NEC / UL compliance | CATV, CM |
| CEC / C(UL) compliance | CM |
| CPR Euroclass | Eca |
| Fire rating | General Purpose (CM, CMG, CMX) |
| UL flammability | UL1685 UL Loading |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2003/96/EC (BFR) | Yes |
| EU Directive 2011/65/EU (RoHS 2) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
| EU directive compliance | EU Directive 2003/11/EC (BFR) |
| EU CE mark | Yes |
| MII Order #39 (China RoHS) | Yes |
| Plenum (Y/N) | No |
| Plenum number | 7916AP |
| Footnote | C - CRATE REEL PUT-UP. |
| Priced Per | FT |