Belden 8219 010, Coax RG 58A U Type Black

SKU:Belden 8219 010
● Auf Lager
Beschreibung
Belden 8219 010 is an RG-58A/U type coaxial cable designed for wireless transmission. It features a 20 AWG (19x32) TC - Tinned Copper conductor with PE - Polyethylene (Foam) insulation and a 95% Tinned Copper (TC) braid shield. A PVC - Polyvinyl Chloride jacket in Black provides protection, and the overall cable diameter (nominal) is 0.193 in (4.90 mm). Key electrical details include a nom. characteristic impedance of 54 Ohm and a UL voltage rating of 300 V (CM), 30 V (UL AWM 1354).
Belden 8219 010 Key Features
- RG type: 58 coaxial construction for wireless transmission applications.
- 20 AWG (19x32) TC - Tinned Copper conductor for a consistent signal path.
- PE - Polyethylene (Foam) insulation with White insulation color code.
- 95% Tinned Copper (TC) braid shield to support signal integrity.
- PVC - Polyvinyl Chloride jacket in Black with an overall cable diameter (nominal) of 0.193 in (4.90 mm).
- UL voltage rating: 300 V (CM), 30 V (UL AWM 1354).
Belden 8219 010 Technical Specs
Electrical & Physical Specs
| Coax construction | Coaxial |
|---|---|
| Nom. conductor diameter | 0.037 in |
| Nom. insulation diameter | 0.116 in (2.95 mm) |
| Outer shield type | Braid |
| Flooded | No not flooded over braid |
Performance & Electrical Characteristics
| Nom. velocity of prop. | 76% |
|---|---|
| Nom. capacitance cond-to-shield | 26.0 pF/ft (85.3 pF/m) |
| Nom. conductor DCR | 8.8 Ohm/1000ft |
| Nom. outer shield DCR | 4.1 Ohm/1000ft (13 Ohm/km) |
| Attenuation (nominal) 1 MHz | 0.4 dB/100ft |
| Attenuation (nominal) 10 MHz | 1.3 dB/100ft |
| Attenuation (nominal) 50 MHz | 3.1 dB/100ft |
| Attenuation (nominal) 100 MHz | 4.5 dB/100ft |
| Attenuation (nominal) 200 MHz | 6.6 dB/100ft |
| Attenuation (nominal) 400 MHz | 10.0 dB/100ft |
| Attenuation (nominal) 700 MHz | 14.2 dB/100ft |
| Attenuation (nominal) 900 MHz | 16.6 dB/100ft |
| Attenuation (nominal) 1000 MHz | 18.1 dB/100ft |
Environmental & Mechanical Ratings
| UL temperature | 80°C |
|---|---|
| Operating temperature | -40°C to +80°C |
| Installation min. bend radius | 1.9 in (48 mm) |
| Max. pull tension | 50 lbs (23 kg) |
| Bulk cable weight | 26 lbs/1000ft |
| Environmental suitability | Outdoor - Aerial, Indoor, Outdoor, UV Resistance, Aerial - When supported by messenger Wire |
Compliance & Certifications
| NEC / UL compliance | CM |
|---|---|
| CEC / C(UL) compliance | CM |
| AWM compliance | AWM 1354 |
| Flammability / reaction to fire | UL1685 UL Loading, UN ECE R118.02 |
| Sustainability | CA Prop 65 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-MSHA-SC-182/5 |
Belden 8219 010 Applications
- Point-to-point and point-to-multipoint wireless antenna communication uses this cable as a coaxial feed line between equipment and antennas.
- Wireless microphones use it to provide a coax connection for RF signal transmission.
- Two-Way Radios commonly use it to connect RF components in radio communication setups.
- Amateur (Ham) Radio systems use it for RF signal routing between radio equipment and antennas.
- Low Power FM installations apply it where coaxial cable is required for RF transmission paths.
- GPS systems use it to carry RF signals between GPS antennas and receiving equipment.
- RFID (Radio Frequency Identification) setups use it to connect RFID antennas and related RF hardware.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Coax construction | Coaxial |
| Nom. conductor diameter | 0.037 in |
| Nom. insulation diameter | 0.116 in (2.95 mm) |
| Outer shield type | Braid |
| Flooded | No not flooded over braid |
| Nom. velocity of prop. | 76% |
| Nom. capacitance (Cond-to-Shield) | 26.0 pF/ft (85.3 pF/m) |
| Nom. conductor DCR | 8.8 Ohm/1000ft |
| Nom. outer shield DCR | 4.1 Ohm/1000ft (13 Ohm/km) |
| Attenuation (nominal) 1 MHz | 0.4 dB/100ft |
| Attenuation (nominal) 10 MHz | 1.3 dB/100ft |
| Attenuation (nominal) 50 MHz | 3.1 dB/100ft |
| Attenuation (nominal) 100 MHz | 4.5 dB/100ft |
| Attenuation (nominal) 200 MHz | 6.6 dB/100ft |
| Attenuation (nominal) 400 MHz | 10.0 dB/100ft |
| Attenuation (nominal) 700 MHz | 14.2 dB/100ft |
| Attenuation (nominal) 900 MHz | 16.6 dB/100ft |
| Attenuation (nominal) 1000 MHz | 18.1 dB/100ft |
| UL temperature | 80°C |
| Operating temperature | -40°C to +80°C |
| Installation min. bend radius | 1.9 in (48 mm) |
| Max Pull Tension | 50 lbs (23 kg) |
| Bulk cable weight | 26 lbs/1000ft |
| Environmental suitability | Outdoor - Aerial, Indoor, Outdoor, UV Resistance, Aerial - When supported by messenger Wire |
| NEC / UL compliance | CM |
| CEC / C(UL) compliance | CM |
| AWM compliance | AWM 1354 |
| Flammability / reaction to fire | UL1685 UL Loading, UN ECE R118.02 |
| Sustainability | CA Prop 65 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-MSHA-SC-182/5 |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.