Belden 8442 060, Multi Conductor Cable 2C 22 AWG PVC

SKU:Belden 8442 060
● Auf Lager
Beschreibung
Belden 8442 060 is a 2-conductor 22 AWG multi conductor cable with stranded (7x30) TC - Tinned Copper conductors, PVC - Polyvinyl Chloride insulation, and a PVC - Polyvinyl Chloride outer jacket. It is rated 300 V with an 80°C UL temperature rating and an operating range of -20°C to +80°C. This cable supports 2.9 Amps per conductor at 25ºC and is intended for indoor electronic and control wiring.
Belden 8442 060 Key Features
- 2-conductor 22 AWG construction with stranded (7x30) TC - Tinned Copper conductors.
- PVC - Polyvinyl Chloride insulation with a PVC - Polyvinyl Chloride outer jacket.
- UL voltage rating: 300 V.
- UL temperature: 80°C; operating: -20°C to +80°C.
- Max. current: 2.9 Amps per conductor at 25ºC.
- NEC / UL compliance: Article 800, CMG; CEC / C(UL) compliance: CMG.
Belden 8442 060 Technical Specs
Construction & Physical Specs
| Conductor material | TC - Tinned Copper |
|---|---|
| Insulation thickness (nom.) | 0.016 in (0.41 mm) |
| Insulation diameter (nom.) | 0.060 in (1.5 mm) |
| Color code | Black, Red |
| Jacket thickness (nom.) | 0.025 in (0.64 mm) |
| Overall cable diameter (nominal) | 0.170 in (4.32 mm) |
| Bulk cable weight | 14 lbs/1000ft |
| Plenum number | 88442, 82442 |
Performance & Electrical Characteristics
| Nom. conductor DCR | 17.8 Ohm/1000ft |
|---|---|
| Nom. capacitance cond-to-cond | 30 pF/ft (98 pF/m) |
| Nom. inductance | 0.2 μH/ft (0.66 μH/m) |
Environmental & Mechanical Ratings
| Bend radius (stationary min.) | 1.7 in (43 mm) |
|---|---|
| Bend radius (installation min.) | 1.7 in (43 mm) |
| Max. pull tension | 18 lbs (8.2 kg) |
| Environmental suitability | Indoor |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEC 60332-1-2 |
Compliance & Certifications
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
|---|---|
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
Belden 8442 060 Applications
- Use it for low voltage analog signals (4-20ma, 0-10v, ...) in electronic and control wiring.
- Choose it for low voltage control (24v, …) where indoor control wiring is required.
- Support line level audio connections in general-purpose wiring setups with this cable.
- Run voice communications wiring in indoor environments.
- Select it for panel wiring in electronic and control applications.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Conductor Material | TC - Tinned Copper |
| Insulation thickness (nom.) | 0.016 in (0.41 mm) |
| Insulation diameter (nom.) | 0.060 in (1.5 mm) |
| Color Code | Black, Red |
| Jacket thickness (nom.) | 0.025 in (0.64 mm) |
| Overall cable diameter (nominal) | 0.170 in (4.32 mm) |
| Bulk cable weight | 14 lbs/1000ft |
| Plenum number | 88442, 82442 |
| Nom. conductor DCR | 17.8 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 30 pF/ft (98 pF/m) |
| Nom. inductance | 0.2 µH/ft (0.66 µH/m) |
| Bend radius (stationary min.) | 1.7 in (43 mm) |
| Bend radius (installation min.) | 1.7 in (43 mm) |
| Max Pull Tension | 18 lbs (8.2 kg) |
| Environmental suitability | Indoor |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.