Belden 8450 010, Multi Conductor 2C 22 AWG Shield PVC FR

SKU:Belden 8450 010
● Auf Lager
Beschreibung
Belden 8450 010 is a 1 pair, 22 AWG twisted pair cable for low voltage signal and control wiring. It features 22 AWG solid tinned copper conductors with PP - Polypropylene insulation, plus an overall Beldfoil® tape shield with 100% coverage and a 22 AWG solid TC drain wire. The PVC - Polyvinyl Chloride jacket is intended for indoor installations where shielding is needed to reduce noise. Key ratings include UL Voltage Rating: 300 V RMS and UL temperature: 75°C.
Belden 8450 010 Key Features
- 1 pair, 22 AWG twisted pair construction for low voltage signal and control wiring.
- 22 AWG solid tinned copper conductors with PP - Polypropylene insulation.
- Overall Beldfoil® tape shield with 100% coverage plus a 22 AWG solid TC drain wire for grounding.
- PVC - Polyvinyl Chloride jacket for indoor installations where shielding is needed to reduce noise.
- UL Voltage Rating: 300 V RMS and UL temperature: 75°C.
Belden 8450 010 Technical Specs
Construction & Materials
| Conductor stranding | Solid |
|---|---|
| Conductor material | TC - Tinned Copper |
| Insulation thickness | 0.007 in (0.18 mm) |
| Insulation color code | Black & Red |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Shield construction | Overall Shield & drain |
| Drain wire | 22 AWG Solid TC |
| Outer jacket thickness | 0.018 in (0.46 mm) |
| Outer jacket nominal diameter | 0.118 in |
Electrical Characteristics
| Nom. conductor DCR | 16.1 Ohm/1000ft (52.8 Ohm/km) |
|---|---|
| Nom outer shield DCR | 12.65 Ohm/1000ft (41.50 Ohm/km) |
| Nom. capacitance (cond-to-cond) | 40 pF/ft (130 pF/m) |
| Nom. capacitance (cond-to-other) | 76 pF/ft (250 pF/m) |
| Nom. characteristic impedence | 40 Ohm |
| Nom. delay | 1.5 ns/ft |
| Nom. inductance | 0.08 μH/ft (0.26 μH/m) |
| Nom. velocity of prop. | 66% |
| Max. current | 2.9 Amps per Conductor at 25ºC |
Environmental & Mechanical Ratings
| Operating temperature | -20°C To +105°C |
|---|---|
| Max. pull tension | 37 lbs (17 kg) |
| Bulk cable weight | 12 lbs/1000ft (18 kg/km) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor |
Compliance & Certifications
| NEC / UL compliance | CM |
|---|---|
| CEC / C(UL) compliance | CM |
| NEC rating | UL Listed Art 800 |
| Flammability / reaction to fire | UL1685 UL Loading, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Applications
- Common uses include low voltage analog signals (4-20ma, 0-10v, ...).
- Low voltage digital control (24v, …) is supported in control and signaling circuits.
- Line level audio connections are a fit where shielding is desired.
- Computer communication wiring is also supported.
- Panel wiring in indoor installations is another typical use.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Conductor stranding | Solid |
| Conductor Material | TC - Tinned Copper |
| Insulation Thickness | 0.007 in (0.18 mm) |
| Insulation color code | Black & Red |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield construction | Overall Shield & drain |
| Drain Wire | 22 AWG Solid TC |
| Outer jacket thickness | 0.018 in (0.46 mm) |
| Outer jacket nominal diameter | 0.118 in |
| Nom. conductor DCR | 16.1 Ohm/1000ft (52.8 Ohm/km) |
| Nom. outer shield DCR | 12.65 Ohm/1000ft (41.50 Ohm/km) |
| Nom. capacitance cond-to-cond | 40 pF/ft (130 pF/m) |
| Nom. capacitance (Cond-to-other) | 76 pF/ft (250 pF/m) |
| Nom. characteristic impedence | 40 Ohm |
| Nom. delay | 1.5 ns/ft |
| Nom. inductance | 0.08 µH/ft (0.26 µH/m) |
| Nom. velocity of prop. | 66% |
| Max. current | 2.9 Amps per Conductor at 25ºC |
| Operating temperature | -20°C To +105°C |
| Max Pull Tension | 37 lbs (17 kg) |
| Bulk cable weight | 12 lbs/1000ft (18 kg/km) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor |
| NEC / UL compliance | CM |
| CEC / C(UL) compliance | CM |
| NEC rating | UL Listed Art 800 |
| Flammability / reaction to fire | UL1685 UL Loading, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.