Belden 8451 010 is a 1 pair 22 AWG twisted pair cable with a PVC - Polyvinyl Chloride jacket for low voltage signal and control wiring in Indoor - Riser applications. It uses 22 AWG stranded (7x30) TC - Tinned Copper conductors with PP - Polypropylene insulation and a paper wrap. An overall Beldfoil® shield (100% coverage) with a 22 AWG stranded TC drain wire helps reduce noise in analog signals (4-20ma, 0-10v, ...) and low voltage digital control (24v, …). It is rated 300 V and supports an operating temperature of -20°C to +75°C.
Belden 8451 010 Key Features
- 1 pair 22 AWG twisted pair construction for low voltage signal and control wiring.
- 22 AWG stranded (7x30) TC - Tinned Copper conductors with PP - Polypropylene insulation and a paper wrap.
- Overall Beldfoil® shield with 100% coverage and a 22 AWG stranded TC drain wire to help reduce noise.
- PVC - Polyvinyl Chloride jacket for Indoor - Riser, Indoor environments.
- UL voltage rating: 300 V.
- Operating temperature: -20°C to +75°C.
- Fire rating: Riser; flammability / reaction to fire: UL 1666 Riser, FT4, IEC 60332-1-2.
Belden 8451 010 Technical Specs
Construction & Materials
| Color code | Black & Red |
|---|---|
| Insulation nominal thickness | 0.009 in (0.23 mm) |
| Insulation nominal diameter | 0.046 in (1.2 mm) |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Jacket nominal thickness | 0.020 in (0.51 mm) |
| Jacket nominal diameter | 0.138 in (3.51 mm) |
Electrical Characteristics
| Nom. conductor DCR | 17.8 Ohm/1000ft (58.4 Ohm/km) |
|---|---|
| Nom outer shield DCR | 14.1 Ohm/1000ft (46.3 Ohm/km) |
| Nom. capacitance cond-to-cond | 34 pF/ft (110 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 67 pF/ft (220 pF/m) |
| Nom. characteristic impedence | 45 Ohm |
| Nom. inductance | 0.17 μH/ft (0.56 μH/m) |
| Nom. inductance cond-grnd | 0.1725 μH/ft |
| Nom. delay | 1.5 ns/ft |
| Nom. velocity of prop. | 66% |
| Max. current | 2.9 Amps per Conductor at 25ºC |
Mechanical & Handling
| Bend radius (stationary min.) | 1.4 in (36 mm) |
|---|---|
| Bend radius (installation min.) | 1.4 in (36 mm) |
| Max. pull tension | 27 lbs (12 kg) |
| Bulk cable weight | 13 lbs/1000ft (19 kg/km) |
Environmental Suitability
| Environmental suitability | Indoor - Riser, Indoor |
|---|---|
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
Compliance & Certifications
| NEC / UL compliance | Article 800, CMR |
|---|---|
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Belden 8451 010 Applications
- Supports low voltage analog signals (4-20ma, 0-10v, ...) where noise reduction is important.
- Handles low voltage digital control (24v, …) in control and signaling circuits.
- Performs well for line level audio signal runs.
- Fits computer communication connections that require a twisted pair and shielded design.
- Commonly used for panel wiring in indoor installations.
- Suitable for use with automatic stripping equipments.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Color Code | Black & Red |
| Insulation nominal thickness | 0.009 in (0.23 mm) |
| Insulation nominal diameter | 0.046 in (1.2 mm) |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Jacket nominal thickness | 0.020 in (0.51 mm) |
| Jacket nominal diameter | 0.138 in (3.51 mm) |
| Nom. conductor DCR | 17.8 Ohm/1000ft (58.4 Ohm/km) |
| Nom. outer shield DCR | 14.1 Ohm/1000ft (46.3 Ohm/km) |
| Nom. capacitance cond-to-cond | 34 pF/ft (110 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 67 pF/ft (220 pF/m) |
| Nom. characteristic impedence | 45 Ohm |
| Nom. inductance | 0.17 µH/ft (0.56 µH/m) |
| Nom. inductance cond-grnd | 0.1725 µH/ft |
| Nom. delay | 1.5 ns/ft |
| Nom. velocity of prop. | 66% |
| Max. current | 2.9 Amps per Conductor at 25ºC |
| Bend radius (stationary min.) | 1.4 in (36 mm) |
| Bend radius (installation min.) | 1.4 in (36 mm) |
| Max Pull Tension | 27 lbs (12 kg) |
| Bulk cable weight | 13 lbs/1000ft (19 kg/km) |
| Environmental suitability | Indoor - Riser, Indoor |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| NEC / UL compliance | Article 800, CMR |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.