Belden 8451 010U, Multi Conductor Cable 2C 22 AWG Shield PVC FR

SKU:Belden 8451 010U
● Auf Lager
Beschreibung
Belden 8451 010U is a 1 pair, 22 AWG multi conductor cable designed for low-voltage signal and control applications. It uses 22 AWG stranded (7x30) TC - tinned copper conductors with PP - polypropylene insulation and a twisted pair construction. An overall Beldfoil® shield with 100% coverage plus a 22 AWG (7x30) TC drain wire helps reduce noise in analog, digital control, audio, and communication circuits. The cable is finished with a PVC - polyvinyl chloride jacket and is suited for indoor - riser installations with Article 800, CMR, and UL 1666 Riser compliance.
Belden 8451 010U Key Features
- This 1 pair, 22 AWG construction is designed for low-voltage signal and control wiring.
- It features 22 AWG stranded (7x30) TC - tinned copper conductors with PP - polypropylene insulation.
- The twisted pair design includes a paper wrap to help maintain consistent pair geometry.
- An overall Beldfoil® shield with 100% coverage and a 22 AWG (7x30) TC drain wire helps reduce noise.
- A PVC - polyvinyl chloride jacket is suited for indoor - riser, indoor installations.
- Compliance includes Article 800, CMR, and UL 1666 Riser.
Belden 8451 010U Technical Specs
Construction & Physical Specs
| Color code | Black & Red |
|---|---|
| Insulation thickness (nom.) | 0.009 in (0.23 mm) |
| Insulation diameter (nom.) | 0.046 in (1.2 mm) |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Jacket thickness (nom.) | 0.020 in (0.51 mm) |
| Cable diameter (nom.) | 0.138 in (3.51 mm) |
| Bulk cable weight | 13 lbs/1000ft (19 kg/km) |
Electrical Ratings & Performance Characteristics
| UL voltage rating | 300 V |
|---|---|
| Nom. conductor DCR | 17.8 Ohm/1000ft (58.4 Ohm/km) |
| Nom. outer shield DCR | 14.1 Ohm/1000ft (46.3 Ohm/km) |
| Nom. capacitance cond-to-cond | 34 pF/ft (110 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 67 pF/ft (220 pF/m) |
| Nom. characteristic impedence | 45 Ohm |
| Nom. inductance cond-grnd | 0.1725 μH/ft |
| Nom. inductance | 0.17 μH/ft (0.56 μH/m) |
| Nom. delay | 1.5 ns/ft |
| Nom. velocity of prop. | 66% |
| Max. current | 2.9 Amps per conductor at 25ºC |
Environmental & Mechanical Ratings
| Operating temperature | -20°C To +75°C |
|---|---|
| Bend radius (stationary min.) | 1.4 in (36 mm) |
| Bend radius (installation min.) | 1.4 in (36 mm) |
| Max. pull tension | 27 lbs (12 kg) |
Compliance & Certifications
| Flammability / reaction to fire | UL 1666 Riser, FT4, IEC 60332-1-2 |
|---|---|
| Fire rating | Riser |
| NEC rating | UL Listed Art 800 Riser |
| CEC / C(UL) compliance | CMG |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Applications
- Use it with automatic stripping equipments during preparation and termination.
- Support low voltage analog signals (4-20ma, 0-10v, ...) in control and instrumentation circuits.
- Choose it for low voltage digital control (24v, …) where shielded signal integrity is needed.
- Apply it to line level audio connections where noise reduction is important.
- Use it for computer communication wiring in low-voltage systems.
- Install it for panel wiring in indoor installations.
Belden™ and all associated trademarks are the property of their respective owners.
Spezifikationen
| Attribute | Value |
|---|---|
| Color Code | Black & Red |
| Insulation thickness (nom.) | 0.009 in (0.23 mm) |
| Insulation diameter (nom.) | 0.046 in (1.2 mm) |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Jacket thickness (nom.) | 0.020 in (0.51 mm) |
| Cable diameter (nom.) | 0.138 in (3.51 mm) |
| Bulk cable weight | 13 lbs/1000ft (19 kg/km) |
| UL Voltage Rating | 300 V |
| Nom. conductor DCR | 17.8 Ohm/1000ft (58.4 Ohm/km) |
| Nom. outer shield DCR | 14.1 Ohm/1000ft (46.3 Ohm/km) |
| Nom. capacitance cond-to-cond | 34 pF/ft (110 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 67 pF/ft (220 pF/m) |
| Nom. characteristic impedence | 45 Ohm |
| Nom. inductance cond-grnd | 0.1725 µH/ft |
| Nom. inductance | 0.17 µH/ft (0.56 µH/m) |
| Nom. delay | 1.5 ns/ft |
| Nom. velocity of prop. | 66% |
| Max. current | 2.9 Amps per conductor at 25ºC |
| Operating temperature | -20°C To +75°C |
| Bend radius (stationary min.) | 1.4 in (36 mm) |
| Bend radius (installation min.) | 1.4 in (36 mm) |
| Max Pull Tension | 27 lbs (12 kg) |
| Flammability / reaction to fire | UL 1666 Riser, FT4, IEC 60332-1-2 |
| Fire rating | Riser |
| NEC rating | UL Listed Art 800 Riser |
| CEC / C(UL) compliance | CMG |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Abbildungen dienen nur als Referenz. Spezifikationen können sich ohne Vorankündigung ändern — prüfen Sie vor dem Kauf die Eignung für Ihre Anwendung. Die Herstellerdokumentation ist maßgeblich.
Brauchen Sie einen Zuschnitt, Mengenpreise oder ein Datenblatt?
Unser Team erstellt Angebote für individuelle Längen und Großbestellungen, meist am selben Tag.